Description
[{“name”:”Color”,”normalizedValue”:”Green”,”rank”:2,”value”:”green”},{“name”:”Depth”,”normalizedValue”:”118.6 mm”,”value”:”118.6 mm”},{“name”:”Height”,”normalizedValue”:”99 mm”,”value”:”99 mm”},{“name”:”Width”,”normalizedValue”:”22.5 mm”,”value”:”22.5 mm”},{“name”:”Product Type”,”normalizedValue”:”Signal Converter”,”value”:”Signal Converter”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Product Name”,”normalizedValue”:”Serial Isolator”,”value”:”Serial Isolator”},{“name”:”Conductor cross section flexible max.”,”normalizedValue”:”2.5 mm²”,”value”:”2.5 mm²”},{“name”:”Noise immunity”,”normalizedValue”:”EN 61000-6-2:2005″,”value”:”EN 61000-6-2:2005″},{“name”:”Typical current consumption”,”normalizedValue”:”40 mA”,”value”:”40 mA (24 V DC)”},{“name”:”Ambient temperature (operation)”,”normalizedValue”:”0 °C … 55 °C”,”value”:”0 °C … 55 °C”},{“name”:”Noise emission”,”normalizedValue”:”EN 61000-6-3″,”value”:”EN 61000-6-3″},{“name”:”Transmission channels”,”normalizedValue”:”4 (2/2), RxD, TxD, RTS, CTS; full duplex”,”value”:”4 (2/2), RxD, TxD, RTS, CTS; full duplex”},{“name”:”Supply voltage range”,”normalizedValue”:”19.2 V AC/DC …, 28.8 V AC/DC”,”value”:”19.2 V AC/DC … 28.8 V AC/DC”},{“name”:”Interface 2″,”normalizedValue”:”V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN 66259-1″,”value”:”V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN 66259-1″},{“name”:”Degree of protection”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”Interface 1″,”normalizedValue”:”V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN 66259-1″,”value”:”V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN 66259-1″},{“name”:”UL, USA/Canada”,”normalizedValue”:”508 recognized, Class I, Div. 2, Groups A, B, C, D”,”value”:”508 recognized, Class I, Div. 2, Groups A, B, C, D”},{“name”:”Test voltage data interfaces”,”normalizedValue”:”2 kV AC”,”value”:”2 kV AC”},{“name”:”Altitude”,”normalizedValue”:”5000 m (For restrictions see manufacturer’s declaration)”,”value”:”5000 m (For restrictions see manufacturer’s declaration)”},{“name”:”Conductor cross section AWG max.”,”normalizedValue”:”13″,”value”:”13″},{“name”:”Housing material”,”normalizedValue”:”PA”,”value”:”PA”},{“name”:”Permissible humidity (operation)”,”normalizedValue”:”10 % … 95 % (non-condensing)”,”value”:”10 % … 95 % (non-condensing)”},{“name”:”Electrical Isolation”,”normalizedValue”:”VCC // V.24 (RS-232) (A) // V.24 (RS-232) (B)”,”value”:”VCC // V.24 (RS-232) (A) // V.24 (RS-232) (B)”},{“name”:”Connection method”,”normalizedValue”:”D-SUB 9 plug, Pluggable screw connection”,”value”:”D-SUB 9 plug, Pluggable screw connection”},{“name”:”Pin assignment”,”normalizedValue”:”DTE/DCE switchover via switch”,”value”:”DTE/DCE switchover via switch”},{“name”:”Conductor cross section AWG min.”,”normalizedValue”:”24″,”value”:”24″},{“name”:”Conformance”,”normalizedValue”:”CE-compliant”,”value”:”CE-compliant”},{“name”:”Electromagnetic compatibility”,”normalizedValue”:”Conformance with EMC Directive 2014/30/EU”,”value”:”Conformance with EMC Directive 2014/30/EU”},{“name”:”Test voltage data interface/power supply”,”normalizedValue”:”2 kVrms (50 Hz, 1 min.)”,”value”:”2 kVrms (50 Hz, 1 min.)”},{“name”:”Conductor cross section flexible min.”,”normalizedValue”:”0.2 mm²”,”value”:”0.2 mm²”},{“name”:”Serial transmission speed”,”normalizedValue”:”115.2 kbps”,”value”:”115.2 kbps”},{“name”:”Transmission length”,”normalizedValue”:”15 m (shielded twisted pair)”,”value”:”15 m (shielded twisted pair)”},{“name”:”Protective circuit”,”normalizedValue”:”Surge protection Suppressor diode”,”value”:”Surge protection Suppressor diode”},{“name”:”Bit distortion”,”normalizedValue”:”< 5 %","value":"< 5 %"},{"name":"Bit delay","normalizedValue":"< 3 µs","value":"< 3 µs"},{"name":"Nominal supply voltage","normalizedValue":"24 V AC/DC ±20 %","value":"24 V AC/DC ±20 %"},{"name":"Protocols supported","normalizedValue":"transparent protocol","value":"transparent protocol"},{"name":"Connection in acc. with standard","normalizedValue":"CUL","value":"CUL"},{"name":"EMC Immunity","normalizedValue":"EN 61000-4-2: Contact discharge ± 6 kV (Test Level 3); EN 61000-4-3: Frequency range Test Level 3; EN 61000-4-4: Criterion B; EN 61000-4-5: Signal ± 2 kV (12 Ω); EN 55011; EN 61000-4-6","value":"EN 61000-4-2: Contact discharge ± 6 kV (Test Level 3); EN 61000-4-3: Frequency range Test Level 3; EN 61000-4-4: Criterion B; EN 61000-4-5: Signal ± 2 kV (12 Ω); EN 55011; EN 61000-4-6"},{"name":"Ambient temperature (storage/transport)","normalizedValue":"-40 °C ... 85 °C","value":"-40 °C ... 85 °C"},{"name":"Country of Origin (subject to change)","normalizedValue":"Germany","value":"Germany"},{"name":"Package Quantity","normalizedValue":"1","value":"1"}]

Reviews
There are no reviews yet.