Description
[{“name”:”Color”,”normalizedValue”:”Green”,”rank”:2,”value”:”green”},{“name”:”Depth”,”normalizedValue”:”105 mm”,”value”:”105 mm”},{“name”:”Width”,”normalizedValue”:”35 mm”,”value”:”35 mm”},{“name”:”Height”,”normalizedValue”:”99 mm”,”value”:”99 mm”},{“name”:”Bit distortion, output”,”normalizedValue”:”\u003c 6.25 %”,”value”:”\u003c 6.25 %”},{“name”:”Transmit capacity, minimum”,”normalizedValue”:”-4 dBm (200/230 µm); -17.6 dBm (50/125 µm); -14 dBm (62,5/125 µm)”,”value”:”-4 dBm (200/230 µm); -17.6 dBm (50/125 µm); -14 dBm (62,5/125 µm)”},{“name”:”Degree of protection”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”Ambient temperature (operation)”,”normalizedValue”:”-20 deg C, 60 deg C”,”value”:”-20 °C … 60 °C”},{“name”:”Conductor cross section solid min.”,”normalizedValue”:”0.2 sq mm”,”value”:”0.2 mm²”},{“name”:”Ambient temperature (storage/transport)”,”normalizedValue”:”-40 °C … 85 °C”,”value”:”-40 °C … 85 °C”},{“name”:”UL, USA/Canada”,”normalizedValue”:”Class I, Zone 2, AEx nc IIC T5; Class I, zone 2, Ex nC nL IIC T5 X; Class I, Div. 2, Groups A, B, C, D”,”value”:”Class I, Zone 2, AEx nc IIC T5; Class I, zone 2, Ex nC nL IIC T5 X; Class I, Div. 2, Groups A, B, C, D”},{“name”:”Transmission protocol”,”normalizedValue”:”Protocol-transparent to the RS-485 interface”,”value”:”Protocol-transparent to the RS-485 interface”},{“name”:”File format/coding”,”normalizedValue”:”UART (11/10 bit switchable; NRZ), slip-tolerant”,”value”:”UART (11/10 bit switchable; NRZ), slip-tolerant”},{“name”:”Electrical Isolation”,”normalizedValue”:”VCC // RS-485″,”value”:”VCC // RS-485″},{“name”:”Housing material”,”normalizedValue”:”PA 6.6-FR”,”value”:”PA 6.6-FR”},{“name”:”Output name”,”normalizedValue”:”Relay output”,”value”:”Relay output”},{“name”:”Altitude”,”normalizedValue”:”5000 m (For restrictions see manufacturer’s declaration)”,”value”:”5000 m (For restrictions see manufacturer’s declaration)”},{“name”:”Supply voltage range”,”normalizedValue”:”18 V DC … 30 V DC”,”value”:”18 V DC … 30 V DC”},{“name”:”Electromagnetic compatibility”,”normalizedValue”:”Conformance with EMC Directive 2014/30/EU”,”value”:”Conformance with EMC Directive 2014/30/EU”},{“name”:”Output description”,”normalizedValue”:”Alarm output”,”value”:”Alarm output”},{“name”:”Data direction switching”,”normalizedValue”:”Automatic control”,”value”:”Automatic control”},{“name”:”Test voltage data interface/power supply”,”normalizedValue”:”1.5 kVrms (50 Hz, 1 min.)”,”value”:”1.5 kVrms (50 Hz, 1 min.)”},{“name”:”Bit delay”,”normalizedValue”:”≤ 1 bit”,”value”:”≤ 1 bit”},{“name”:”Maximum switching voltage”,”normalizedValue”:”60 V DC; 42 V AC”,”value”:”60 V DC; 42 V AC”},{“name”:”Type of test”,”normalizedValue”:”Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6, Shock in acc. with EN 60068-2-27/IEC 60068-2-27″,”value”:”Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6, Shock in acc. with EN 60068-2-27/IEC 60068-2-27″},{“name”:”Shock”,”normalizedValue”:”15g in all directions in acc. with IEC 60068-2-27″,”value”:”15g in all directions in acc. with IEC 60068-2-27″},{“name”:”Conductor cross section flexible max.”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Noise emission”,”normalizedValue”:”EN 55011″,”value”:”EN 55011″},{“name”:”Conductor cross section AWG min.”,”normalizedValue”:”24″,”value”:”24″},{“name”:”Nominal supply voltage”,”normalizedValue”:”24 V DC”,”value”:”24 V DC (With UL approval)”},{“name”:”Number of FO ports”,”normalizedValue”:”2″,”value”:”2″},{“name”:”ATEX”,”normalizedValue”:”II 3 G Ex nA nC IIC T4 Gc X; II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U; II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U)”,”value”:”II 3 G Ex nA nC IIC T4 Gc X; II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U; II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U)”},{“name”:”Serial transmission speed”,”normalizedValue”:”4.8/ 9.6/ 19.2/ 38.4/ 57.6/ 75/ 93.75/ 115.2/ 136/ 187.5/ 375/ 500 kbps”,”value”:”4.8/ 9.6/ 19.2/ 38.4/ 57.6/ 75/ 93.75/ 115.2/ 136/ 187.5/ 375/ 500 kbps”},{“name”:”Wavelength”,”normalizedValue”:”850 nm”,”value”:”850 nm”},{“name”:”Free from substances that could impair the application of coating”,”normalizedValue”:”according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard”,”value”:”according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard”},{“name”:”Conductor cross section AWG max.”,”normalizedValue”:”14″,”value”:”14″},{“name”:”Conductor cross section flexible min.”,”normalizedValue”:”0.2 sq mm”,”value”:”0.2 mm²”},{“name”:”Bit distortion, input”,”normalizedValue”:”± 35 %”,”value”:”± 35 % (permitted)”},{“name”:”Transmission medium”,”normalizedValue”:”Copper, PCF fiber; Multi-mode fiberglass”,”value”:”Copper, PCF fiber; Multi-mode fiberglass”},{“name”:”Minimum receiver sensitivity”,”normalizedValue”:”-32.5 dBm (50/125 µm); -32.5 dBm (62,5/125 µm); -32.1 dBm (200/230 µm)”,”value”:”-32.5 dBm (50/125 µm); -32.5 dBm (62,5/125 µm); -32.1 dBm (200/230 µm)”},{“name”:”Permissible humidity (operation)”,”normalizedValue”:”30 % … 95 %”,”value”:”30 % … 95 % (non-condensing)”},{“name”:”Number of outputs”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Max. current consumption”,”normalizedValue”:”130 mA”,”value”:”130 mA”},{“name”:”Connection method”,”normalizedValue”:”B-FOC (duplex ST®), Pluggable screw connection, COMBICON plug-in screw terminal block”,”value”:”B-FOC (duplex ST®), Pluggable screw connection, COMBICON plug-in screw terminal block”},{“name”:”Transmission length incl. 3 dB system reserve”,”normalizedValue”:”2800 m (with F-K 200/230 8 dB/km with quick mounting connector); 4200 m (with F-G 50/125 2.5 dB/km); 3300 m (with F-G 62,5/125 3.0 dB/km)”,”value”:”2800 m (with F-K 200/230 8 dB/km with quick mounting connector); 4200 m (with F-G 50/125 2.5 dB/km); 3300 m (with F-G 62,5/125 3.0 dB/km)”},{“name”:”Test result”,”normalizedValue”:”5g, 10-150 Hz, 2.5 h, in XYZ direction, 15g, 11 ms period, half-sine shock pulse”,”value”:”5g, 10-150 Hz, 2.5 h, in XYZ direction, 15g, 11 ms period, half-sine shock pulse”},{“name”:”Termination resistor”,”normalizedValue”:”390 Ω, 220 Ω”,”value”:”390 Ω; 220 Ω; 390 Ω (Can be connected)”},{“name”:”Limiting continuous current”,”normalizedValue”:”0.46 A”,”value”:”0.46 A”},{“name”:”Transmission length”,”normalizedValue”:”≤ 1200 m (depending on the data rate, with shielded, twisted data cable)”,”value”:”≤ 1200 m (depending on the data rate, with shielded, twisted data cable)”},{“name”:”Typical current consumption”,”normalizedValue”:”120 mA (24 V DC)”,”value”:”120 mA (24 V DC)”},{“name”:”Conductor cross section solid max.”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Vibration (operation)”,”normalizedValue”:”In acc. with IEC 60068-2-6: 5g, 150 Hz”,”value”:”In acc. with IEC 60068-2-6: 5g, 150 Hz”},{“name”:”Connection in acc. with standard”,”normalizedValue”:”CUL”,”value”:”CUL”},{“name”:”Conformance”,”normalizedValue”:”CE-compliant”,”value”:”CE-compliant”},{“name”:”Overrange receiver”,”normalizedValue”:”-3 dBm (200/230 µm)”,”value”:”-3 dBm (200/230 µm)”},{“name”:”Operating mode”,”normalizedValue”:”Semi-duplex”,”value”:”Semi-duplex”},{“name”:”Noise immunity”,”normalizedValue”:”EN 61000-6-2:2005″,”value”:”EN 61000-6-2:2005″},{“name”:”Interface 1″,”normalizedValue”:”RS-485 interface, 2-wire”,”value”:”RS-485 interface, 2-wire”},{“name”:”Standards/regulations”,”normalizedValue”:”EN 61000-4-2; EN 61000-4-3; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6″,”value”:”EN 61000-4-2; EN 61000-4-3; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Germany”,”value”:”Germany”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.