Description
[{“name”:”Color”,”normalizedValue”:”Green”,”rank”:2,”value”:”green”},{“name”:”Width”,”normalizedValue”:”35 mm”,”value”:”35 mm”},{“name”:”Depth”,”normalizedValue”:”105 mm”,”value”:”105 mm”},{“name”:”Height”,”normalizedValue”:”99 mm”,”value”:”99 mm”},{“name”:”Supply voltage range”,”normalizedValue”:”18 V DC … 30 V DC”,”value”:”18 V DC … 30 V DC”},{“name”:”Test voltage data interface/power supply”,”normalizedValue”:”1.5 kVrms (50 Hz, 1 min.)”,”value”:”1.5 kVrms (50 Hz, 1 min.)”},{“name”:”Maximum switching voltage”,”normalizedValue”:”60 V DC; 42 V AC”,”value”:”60 V DC; 42 V AC”},{“name”:”Conductor cross section flexible min.”,”normalizedValue”:”0.2 mm²”,”value”:”0.2 mm²”},{“name”:”File format/coding”,”normalizedValue”:”UART (11/10 bit switchable; NRZ), slip-tolerant”,”value”:”UART (11/10 bit switchable; NRZ), slip-tolerant”},{“name”:”Vibration (operation)”,”normalizedValue”:”In acc. with IEC 60068-2-6: 5g, 150 Hz”,”value”:”In acc. with IEC 60068-2-6: 5g, 150 Hz”},{“name”:”Bit distortion, output”,”normalizedValue”:”< 6.25 %","value":"< 6.25 %"},{"name":"Conductor cross section solid max.","normalizedValue":"2.5 mm²","value":"2.5 mm²"},{"name":"Conductor cross section solid min.","normalizedValue":"0.2 mm²","value":"0.2 mm²"},{"name":"Standards/regulations","normalizedValue":"EN 61000-4-2; EN 61000-4-3; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6","value":"EN 61000-4-2; EN 61000-4-3; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6"},{"name":"Test result","normalizedValue":"5g, 10-150 Hz, 2.5 h, in XYZ direction, 15g, 11 ms period, half-sine shock pulse","value":"5g, 10-150 Hz, 2.5 h, in XYZ direction, 15g, 11 ms period, half-sine shock pulse"},{"name":"Output description","normalizedValue":"Alarm output","value":"Alarm output"},{"name":"Conductor cross section AWG min.","normalizedValue":"24","value":"24"},{"name":"Degree of protection","normalizedValue":"IP20","value":"IP20"},{"name":"Serial transmission speed","normalizedValue":"4.8/ 9.6/ 19.2/ 38.4/ 57.6/ 75/ 93.75/ 115.2/ 136/ 187.5/ 375/ 500 kbps","value":"4.8/ 9.6/ 19.2/ 38.4/ 57.6/ 75/ 93.75/ 115.2/ 136/ 187.5/ 375/ 500 kbps"},{"name":"Operating mode","normalizedValue":"Semi-duplex","value":"Semi-duplex"},{"name":"Free from substances that could impair the application of coating","normalizedValue":"according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard","value":"according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard"},{"name":"Noise emission","normalizedValue":"EN 55011","value":"EN 55011"},{"name":"Max. current consumption","normalizedValue":"130 mA","value":"130 mA"},{"name":"Noise immunity","normalizedValue":"EN 61000-6-2:2005","value":"EN 61000-6-2:2005"},{"name":"Ambient temperature (storage/transport)","normalizedValue":"-40 °C ... 85 °C","value":"-40 °C ... 85 °C"},{"name":"Termination resistor","normalizedValue":"390 Ω; 220 Ω; 390 Ω (Can be connected)","value":"390 Ω; 220 Ω; 390 Ω (Can be connected)"},{"name":"ATEX","normalizedValue":"II 3 G Ex nA nC IIC T4 Gc X; II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U); II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U)","value":"II 3 G Ex nA nC IIC T4 Gc X; II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U); II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U)"},{"name":"Housing material","normalizedValue":"PA 6.6-FR","value":"PA 6.6-FR"},{"name":"Wavelength","normalizedValue":"850 nm","value":"850 nm"},{"name":"Conductor cross section flexible max.","normalizedValue":"2.5 mm²","value":"2.5 mm²"},{"name":"Permissible humidity (operation)","normalizedValue":"30 % ... 95 % (non-condensing)","value":"30 % ... 95 % (non-condensing)"},{"name":"Electrical Isolation","normalizedValue":"VCC // RS-485","value":"VCC // RS-485"},{"name":"Overrange receiver","normalizedValue":"-3 dBm (200/230 µm)","value":"-3 dBm (200/230 µm)"},{"name":"Output name","normalizedValue":"Relay output","value":"Relay output"},{"name":"Bit delay","normalizedValue":"≤ 1 bit","value":"≤ 1 bit"},{"name":"Interface 1","normalizedValue":"RS-485 interface, 2-wire","value":"RS-485 interface, 2-wire"},{"name":"UL, USA/Canada","normalizedValue":"Class I, Zone 2, AEx nc IIC T5; Class I, zone 2, Ex nC nL IIC T5 X; Class I, Div. 2, Groups A, B, C, D","value":"Class I, Zone 2, AEx nc IIC T5; Class I, zone 2, Ex nC nL IIC T5 X; Class I, Div. 2, Groups A, B, C, D"},{"name":"Number of FO ports","normalizedValue":"1","value":"1"},{"name":"Conformance","normalizedValue":"CE-compliant","value":"CE-compliant"},{"name":"Transmission medium","normalizedValue":"PCF fiber; Multi-mode fiberglass, Copper","value":"PCF fiber; Multi-mode fiberglass, Copper"},{"name":"Connection in acc. with standard","normalizedValue":"CUL","value":"CUL"},{"name":"Electromagnetic compatibility","normalizedValue":"Conformance with EMC Directive 2014/30/EU","value":"Conformance with EMC Directive 2014/30/EU"},{"name":"Number of outputs","normalizedValue":"1","value":"1"},{"name":"Type of test","normalizedValue":"Shock in acc. with EN 60068-2-27/IEC 60068-2-27, Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6","value":"Shock in acc. with EN 60068-2-27/IEC 60068-2-27, Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6"},{"name":"Limiting continuous current","normalizedValue":"0.46 A","value":"0.46 A"},{"name":"Conductor cross section AWG max.","normalizedValue":"14","value":"14"},{"name":"Nominal supply voltage","normalizedValue":"24 V DC (With UL approval)","value":"24 V DC (With UL approval)"},{"name":"Altitude","normalizedValue":"5000 m (For restrictions see manufacturer's declaration)","value":"5000 m (For restrictions see manufacturer's declaration)"},{"name":"Connection method","normalizedValue":"COMBICON plug-in screw terminal block, Pluggable screw connection, B-FOC (duplex ST®)","value":"COMBICON plug-in screw terminal block, Pluggable screw connection, B-FOC (duplex ST®)"},{"name":"Bit distortion, input","normalizedValue":"± 35 % (permitted)","value":"± 35 % (permitted)"},{"name":"Minimum receiver sensitivity","normalizedValue":"-32.5 dBm (50/125 µm); -32.5 dBm (62,5/125 µm); -32.1 dBm (200/230 µm)","value":"-32.5 dBm (50/125 µm); -32.5 dBm (62,5/125 µm); -32.1 dBm (200/230 µm)"},{"name":"Transmit capacity, minimum","normalizedValue":"-4 dBm (200/230 µm); -17.6 dBm (50/125 µm); -14 dBm (62,5/125 µm)","value":"-4 dBm (200/230 µm); -17.6 dBm (50/125 µm); -14 dBm (62,5/125 µm)"},{"name":"Transmission length","normalizedValue":"≤ 1200 m (depending on the data rate, with shielded, twisted data cable)","value":"≤ 1200 m (depending on the data rate, with shielded, twisted data cable)"},{"name":"Ambient temperature (operation)","normalizedValue":"-20 °C ... 60 °C","value":"-20 °C ... 60 °C"},{"name":"Transmission length incl. 3 dB system reserve","normalizedValue":"2800 m (with F-K 200/230 8 dB/km with quick mounting connector); 4200 m (with F-G 50/125 2.5 dB/km); 3300 m (with F-G 62,5/125 3.0 dB/km)","value":"2800 m (with F-K 200/230 8 dB/km with quick mounting connector); 4200 m (with F-G 50/125 2.5 dB/km); 3300 m (with F-G 62,5/125 3.0 dB/km)"},{"name":"Shock","normalizedValue":"15g in all directions in acc. with IEC 60068-2-27","value":"15g in all directions in acc. with IEC 60068-2-27"},{"name":"Transmission protocol","normalizedValue":"Protocol-transparent to the RS-485 interface","value":"Protocol-transparent to the RS-485 interface"},{"name":"Data direction switching","normalizedValue":"Automatic control","value":"Automatic control"},{"name":"Typical current consumption","normalizedValue":"120 mA","value":"120 mA (24 V DC)"},{"name":"Country of Origin (subject to change)","normalizedValue":"Germany","value":"Germany"},{"name":"Package Quantity","normalizedValue":"1","value":"1"}]

Reviews
There are no reviews yet.