Description
[{“name”:”Color”,”normalizedValue”:”Green”,”rank”:2,”value”:”green”},{“name”:”Depth”,”normalizedValue”:”4.1 in”,”value”:”4.1 in”},{“name”:”Width”,”normalizedValue”:”1.4 in”,”value”:”1.4 in”},{“name”:”Height”,”normalizedValue”:”3.9 in”,”value”:”3.9 in”},{“name”:”Fiber Optic Wavelength”,”normalizedValue”:”850 nm”,”value”:”850 nm”},{“name”:”Form Factor”,”normalizedValue”:”Rail-mountable”,”value”:”Rail-mountable”},{“name”:”Product Type”,”normalizedValue”:”Transceiver/Media Converter”,”value”:”Transceiver/Media Converter”},{“name”:”Fiber Mode Supported”,”normalizedValue”:”Multi-mode”,”value”:”Multi-mode”},{“name”:”Environmentally Friendly”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Media Type Supported”,”normalizedValue”:”Optical Fiber”,”value”:”Optical Fiber”},{“name”:”ST Port Type”,”normalizedValue”:”Duplex”,”value”:”Duplex”},{“name”:”Power Source”,”normalizedValue”:”Power Supply”,”value”:”Power Supply”},{“name”:”Fiber Optic Cable Standard”,”normalizedValue”:”50/125 µm, 62.5/125 µm”,”value”:”50/125 µm, 62.5/125 µm”},{“name”:”Product Name”,”normalizedValue”:”PSI-MOS-RS422/FO 850 T Transceiver/Media Converter”,”value”:”PSI-MOS-RS422/FO 850 T Transceiver/Media Converter”},{“name”:”Maximum Distance Supported”,”normalizedValue”:”2.61 mi”,”value”:”2.61 Mile”},{“name”:”Number of ST Ports”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Weight (Approximate)”,”normalizedValue”:”7.39 oz”,”value”:”7.39 oz”},{“name”:”Total Number of Ports”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Conductor cross section solid min.”,”normalizedValue”:”0.2 sq mm”,”value”:”0.2 mm²”},{“name”:”Maximum switching voltage”,”normalizedValue”:”60 V DC; 42 V AC”,”value”:”60 V DC; 42 V AC”},{“name”:”Serial transmission speed”,”normalizedValue”:”≤ 2 Mbps”,”value”:”≤ 2 Mbps”},{“name”:”Ambient temperature (operation)”,”normalizedValue”:”-20 deg C, 60 deg C”,”value”:”-20 °C … 60 °C”},{“name”:”Output description”,”normalizedValue”:”Alarm output”,”value”:”Alarm output”},{“name”:”Interface 1″,”normalizedValue”:”RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1″,”value”:”RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1″},{“name”:”Vibration (operation)”,”normalizedValue”:”In acc. with IEC 60068-2-6: 5g, 150 Hz”,”value”:”In acc. with IEC 60068-2-6: 5g, 150 Hz”},{“name”:”Transmission length”,”normalizedValue”:”≤ 1000 m (depending on the data rate, with shielded, twisted data cable)”,”value”:”≤ 1000 m (depending on the data rate, with shielded, twisted data cable)”},{“name”:”Electrical Isolation”,”normalizedValue”:”VCC // RS-422″,”value”:”VCC // RS-422″},{“name”:”Standards/regulations”,”normalizedValue”:”EN 61000-4-2; EN 61000-4-3; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6″,”value”:”EN 61000-4-2; EN 61000-4-3; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6″},{“name”:”Transmit capacity, minimum”,”normalizedValue”:”-4.6 dBm (200/230 µm); -17.6 dBm (50/125 µm); -13.6 dBm (62,5/125 µm)”,”value”:”-4.6 dBm (200/230 µm); -17.6 dBm (50/125 µm); -13.6 dBm (62,5/125 µm)”},{“name”:”Altitude”,”normalizedValue”:”5000 m (For restrictions see manufacturer’s declaration)”,”value”:”5000 m (For restrictions see manufacturer’s declaration)”},{“name”:”Type of test”,”normalizedValue”:”Shock in acc. with EN 60068-2-27/IEC 60068-2-27, Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6″,”value”:”Shock in acc. with EN 60068-2-27/IEC 60068-2-27, Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6″},{“name”:”Test voltage data interface/power supply”,”normalizedValue”:”1.5 kVrms (50 Hz, 1 min.)”,”value”:”1.5 kVrms (50 Hz, 1 min.)”},{“name”:”Noise emission”,”normalizedValue”:”EN 55011″,”value”:”EN 55011″},{“name”:”Connection method”,”normalizedValue”:”B-FOC (duplex ST®), COMBICON plug-in screw terminal block, Pluggable screw connection”,”value”:”B-FOC (duplex ST®), COMBICON plug-in screw terminal block, Pluggable screw connection”},{“name”:”Bit distortion, output”,”normalizedValue”:”\u003c 6.25 %”,”value”:”\u003c 6.25 %”},{“name”:”Typical current consumption”,”normalizedValue”:”120 mA (24 V DC)”,”value”:”120 mA (24 V DC)”},{“name”:”UL, USA/Canada”,”normalizedValue”:”Class I, Zone 2, AEx nc IIC T5; Class I, zone 2, Ex nC nL IIC T5 X; Class I, Div. 2, Groups A, B, C, D”,”value”:”Class I, Zone 2, AEx nc IIC T5; Class I, zone 2, Ex nC nL IIC T5 X; Class I, Div. 2, Groups A, B, C, D”},{“name”:”Minimum receiver sensitivity”,”normalizedValue”:”-33.2 dBm”,”value”:”-33.2 dBm”},{“name”:”Permissible humidity (operation)”,”normalizedValue”:”30 % … 95 %”,”value”:”30 % … 95 % (non-condensing)”},{“name”:”Bit distortion, input”,”normalizedValue”:”± 35 %”,”value”:”± 35 % (permitted)”},{“name”:”Housing material”,”normalizedValue”:”PA 6.6-FR”,”value”:”PA 6.6-FR”},{“name”:”Transmission length incl. 3 dB system reserve”,”normalizedValue”:”2800 m (With F-K 200/230 10 dB/km with quick mounting connector); 4200 m (with F-G 50/125 2.5 dB/km); 4800 m (with F-G 62,5/125 3.0 dB/km)”,”value”:”2800 m (With F-K 200/230 10 dB/km with quick mounting connector); 4200 m (with F-G 50/125 2.5 dB/km); 4800 m (with F-G 62,5/125 3.0 dB/km)”},{“name”:”ATEX”,”normalizedValue”:”II 3 G Ex nA nC IIC T4 Gc X; II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U); II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U)”,”value”:”II 3 G Ex nA nC IIC T4 Gc X; II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U); II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U)”},{“name”:”Noise immunity”,”normalizedValue”:”EN 61000-6-2:2005″,”value”:”EN 61000-6-2:2005″},{“name”:”Conductor cross section flexible min.”,”normalizedValue”:”0.2 sq mm”,”value”:”0.2 mm²”},{“name”:”Max. current consumption”,”normalizedValue”:”130 mA”,”value”:”130 mA”},{“name”:”Number of outputs”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Electromagnetic compatibility”,”normalizedValue”:”Conformance with EMC Directive 2014/30/EU”,”value”:”Conformance with EMC Directive 2014/30/EU”},{“name”:”Nominal supply voltage”,”normalizedValue”:”24 V DC”,”value”:”24 V DC (With UL approval)”},{“name”:”Conductor cross section AWG min.”,”normalizedValue”:”24″,”value”:”24″},{“name”:”Transmission medium”,”normalizedValue”:”PCF fiber; Multi-mode fiberglass, Copper”,”value”:”PCF fiber; Multi-mode fiberglass, Copper”},{“name”:”Supply voltage range”,”normalizedValue”:”18 V DC … 30 V DC”,”value”:”18 V DC … 30 V DC”},{“name”:”Output name”,”normalizedValue”:”Relay output”,”value”:”Relay output”},{“name”:”Transmission protocol”,”normalizedValue”:”Transparent to protocol for interface”,”value”:”Transparent to protocol for RS-422 interface”},{“name”:”Operating mode”,”normalizedValue”:”Full duplex”,”value”:”Full duplex”},{“name”:”Limiting continuous current”,”normalizedValue”:”0.46 A”,”value”:”0.46 A”},{“name”:”Number of FO ports”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Shock”,”normalizedValue”:”15g in all directions in acc. with IEC 60068-2-27″,”value”:”15g in all directions in acc. with IEC 60068-2-27″},{“name”:”Transmission channels”,”normalizedValue”:”2 (1/1) RD, TD, full duplex”,”value”:”2 (1/1) RD, TD, full duplex”},{“name”:”Termination resistor”,”normalizedValue”:”220 Ω, 100 Ω”,”value”:”220 Ω; 100 Ω; 220 Ω”},{“name”:”Degree of protection”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”Ambient temperature (storage/transport)”,”normalizedValue”:”-40 °C … 85 °C”,”value”:”-40 °C … 85 °C”},{“name”:”Connection in acc. with standard”,”normalizedValue”:”CUL”,”value”:”CUL”},{“name”:”Conductor cross section solid max.”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Conductor cross section AWG max.”,”normalizedValue”:”14″,”value”:”14″},{“name”:”Conductor cross section flexible max.”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Conformance”,”normalizedValue”:”CE-compliant”,”value”:”CE-compliant”},{“name”:”Test result”,”normalizedValue”:”15g, 11 ms period, half-sine shock pulse, 5g, 10-150 Hz, 2.5 h, in XYZ direction”,”value”:”15g, 11 ms period, half-sine shock pulse, 5g, 10-150 Hz, 2.5 h, in XYZ direction”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Germany”,”value”:”Germany”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.