Pp-Rj-Idc Patch Panel

$172,99

PP-RJ-IDC DIN Rail Patch Panel: 1 x RJ45 socket, 1 x IDC terminal block, 10/100/1000 Mbps, IP20, shield contacting with strain relief

Out of stock

SKU: GRG4571134 Category:

Description

[{“name”:”Height”,”normalizedValue”:”101.3 mm”,”value”:”101.3 mm”},{“name”:”Color”,”normalizedValue”:”Gray”,”value”:”Gray”},{“name”:”Width”,”normalizedValue”:”23.8 mm”,”value”:”23.8 mm”},{“name”:”Depth”,”normalizedValue”:”50 mm”,”value”:”50 mm”},{“name”:”Maximum output power”,”normalizedValue”:”60 W”,”value”:”60 W”},{“name”:”Permissible humidity (operation)”,”normalizedValue”:”10 % … 95 % (non-condensing)”,”value”:”10 % … 95 % (non-condensing)”},{“name”:”Output nominal voltage”,”normalizedValue”:”< 60 V (ATEX approval)","value":"< 60 V (ATEX approval)"},{"name":"Caption","normalizedValue":"Compact housing","value":"Compact housing"},{"name":"Overvoltage category","normalizedValue":"II","value":"II"},{"name":"Housing material","normalizedValue":"Plastic","value":"Plastic"},{"name":"Conductor cross section solid max.","normalizedValue":"0.34 mm²","value":"0.34 mm²"},{"name":"Degree of pollution","normalizedValue":"2","value":"2"},{"name":"UL, Canada","normalizedValue":"CSA22.2 No.60079-0 Ed.3 / CSA22.2 No.60079-15:16","value":"CSA22.2 No.60079-0 Ed.3 / CSA22.2 No.60079-15:16"},{"name":"Rated insulation voltage","normalizedValue":"85 V DC","value":"85 V DC"},{"name":"Maximum output current","normalizedValue":"725 mA (Per channel)","value":"725 mA (Per channel)"},{"name":"ATEX","normalizedValue":"ï˜ II 3 G Ex nA IIC Gc U","value":"ï˜ II 3 G Ex nA IIC Gc U"},{"name":"Wire diameter incl. insulation","normalizedValue":"1.6 mm (Terminal block is tested with PVC insulation - other insulation materials available on request)","value":"1.6 mm (Terminal block is tested with PVC insulation - other insulation materials available on request)"},{"name":"Serial transmission speed","normalizedValue":"10/100/1000 Mbps","value":"10/100/1000 Mbps"},{"name":"Interface 2","normalizedValue":"Ethernet interface, 10/100/1000 Base-T(X) according to IEEE 802.3u","value":"Ethernet interface, 10/100/1000 Base-T(X) according to IEEE 802.3u"},{"name":"Conductor cross section solid min.","normalizedValue":"0.14 mm²","value":"0.14 mm²"},{"name":"Altitude","normalizedValue":"5000 m (For restrictions see manufacturer's declaration) / 2000 m (ATEX approval)","value":"5000 m (For restrictions see manufacturer's declaration) / 2000 m (ATEX approval)"},{"name":"Interface 1","normalizedValue":"Ethernet interface, 10/100/1000 Base-T(X) according to IEEE 802.3u","value":"Ethernet interface, 10/100/1000 Base-T(X) according to IEEE 802.3u"},{"name":"Type of test","normalizedValue":"Vibration resistance in acc. with EN60068-2-6/IEC60068-2-6, Shock in acc. with EN60068-2-27/IEC60068-2-27, Continuous shock according to EN60068-2-27/IEC60068-2-27","value":"Vibration resistance in acc. with EN60068-2-6/IEC60068-2-6, Shock in acc. with EN60068-2-27/IEC60068-2-27, Continuous shock according to EN60068-2-27/IEC60068-2-27"},{"name":"Ambient temperature (storage/transport)","normalizedValue":"-40°C ... 85°C","value":"-40°C ... 85°C"},{"name":"Ambient temperature (operation)","normalizedValue":"-40°C ... 75°C","value":"-40°C ... 75°C"},{"name":"Transmission length","normalizedValue":"100 m (including patch cables)","value":"100 m (including patch cables)"},{"name":"Conductor cross section flexible min.","normalizedValue":"0.14 mm²","value":"0.14 mm²"},{"name":"Conformance","normalizedValue":"CE-compliant","value":"CE-compliant"},{"name":"MTTF","normalizedValue":"105699 Years","value":"105699 Years"},{"name":"Pin assignment","normalizedValue":"1:1","value":"1:1"},{"name":"Conductor cross section AWG min.","normalizedValue":"26","value":"26"},{"name":"Conductor cross section AWG max.","normalizedValue":"22","value":"22"},{"name":"UL, USA","normalizedValue":"UL60079-0 Ed.6 / UL60079-15 Ed.4","value":"UL60079-0 Ed.6 / UL60079-15 Ed.4"},{"name":"Test result","normalizedValue":"10Hz...57Hz, amplitude ±3.5mm, 57Hz...150Hz, 5g, 30g for 11ms, three shocks in each spatial direction, 10g for 16ms, 1000shocks in each spatial direction","value":"10Hz...57Hz, amplitude ±3.5mm, 57Hz...150Hz, 5g, 30g for 11ms, three shocks in each spatial direction, 10g for 16ms, 1000shocks in each spatial direction"},{"name":"Degree of protection","normalizedValue":"IP20 (Manufacturer's declaration)","value":"IP20 (Manufacturer's declaration)"},{"name":"Conductor cross section flexible max.","normalizedValue":"0.34 mm²","value":"0.34 mm²"},{"name":"Connection method","normalizedValue":"IDC connection, RJ45 CAT5e","value":"IDC connection, RJ45 CAT5e"},{"name":"Noxious gas test","normalizedValue":"ISA-S71.04-1985 G3 Harsh Group A","value":"ISA-S71.04-1985 G3 Harsh Group A"},{"name":"Country of Origin (subject to change)","normalizedValue":"Germany","value":"Germany"},{"name":"Package Quantity","normalizedValue":"1","value":"1"}]

Reviews

There are no reviews yet.

Be the first to review “Pp-Rj-Idc Patch Panel”