Power plug-in relay, 15 A, 4 CO, 48 V DC, 48V DC Coil Volts, 4 C/O

$14,95

Power plug-in relay,15 A,4 CO,48 V DC

Out of stock

SKU: GRG000904848 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Power plug-in relay,15 A,4 CO,48 V DC”,”rank”:1,”value”:”Power plug-in relay,15 A,4 CO,48 V DC”},{“name”:”Coil Volts”,”normalizedValue”:”48V DC”,”rank”:2,”value”:”48V DC”},{“name”:”AC Contact Rating – Relay”,”normalizedValue”:”15A @ 250V AC”,”rank”:3,”value”:”15A @ 250V AC”},{“name”:”DC Contact Rating – Relay”,”normalizedValue”:”15 A @ 28 V”,”rank”:4,”value”:”15A @ 28V DC”},{“name”:”Contact Form – Relay”,”normalizedValue”:”4 C/O”,”rank”:7,”value”:”4 C/O”},{“name”:”Power Consumption – Relay”,”normalizedValue”:”1.6 W”,”rank”:10,”value”:”1.6 W”},{“name”:”Contact Material”,”normalizedValue”:”AgNi”,”rank”:11,”value”:”AgNi”},{“name”:”Features”,”normalizedValue”:”Lockable Test Button”,”rank”:16,”value”:”Lockable Test Button”},{“name”:”Standards”,”normalizedValue”:”CSA C22.2 No 14; EN/IEC 61810-1; UL 508; EAC”,”rank”:17,”value”:”CSA C22.2 No 14; EN/IEC 61810-1; UL 508; EAC”},{“name”:”Operating Temp. Range”,”normalizedValue”:”-40-55°C”,”value”:”-40-55°C”},{“name”:”Current Rating”,”normalizedValue”:”15 A 277 V AC) UL; 15 A 28 V DC) UL; 15 A 250 V AC) NO IEC; 15 A 28 V DC) NO IEC; 7.5 A 250 V AC) NC IEC; 7.5 A 28 V DC) NC IEC”,”value”:”15 A 277 V AC) UL; 15 A 28 V DC) UL; 15 A 250 V AC) NO IEC; 15 A 28 V DC) NO IEC; 7.5 A 250 V AC) NC IEC; 7.5 A 28 V DC) NC IEC”},{“name”:”Switching Voltage”,”normalizedValue”:”250 V IEC”,”value”:”250 V IEC”},{“name”:”Pin Shape”,”normalizedValue”:”Flat”,”value”:”flat”},{“name”:”Coil Resistance”,”normalizedValue”:”1,210 ohms”,”value”:”1210 Ohm”},{“name”:”Dielectric Strength”,”normalizedValue”:”1500 V AC between contacts with micro disconnection; 2000 V AC between coil and contact with reinforced; 2000 V AC between poles with basic”,”value”:”1500 V AC between contacts with micro disconnection; 2000 V AC between coil and contact with reinforced; 2000 V AC between poles with basic”},{“name”:”Switching Power”,”normalizedValue”:”Max 3750 VA; 420 W; Min 170 mW 10 mA, 17 V”,”value”:”Max 3750 VA; 420 W; Min 170 mW 10 mA, 17 V”},{“name”:”Operating Time”,”normalizedValue”:”20 ms at nominal voltage”,”value”:”20 ms at nominal voltage”},{“name”:”Series”,”normalizedValue”:”RPM; Power”,”value”:”RPM; Power”},{“name”:”Protection Category”,”normalizedValue”:”RT I”,”value”:”RT I”},{“name”:”Minimum Switching Capacity”,”normalizedValue”:”170 mW 10 mA, 17 V”,”value”:”170 mW 10 mA, 17 V”},{“name”:”Status LED”,”normalizedValue”:”Without”,”value”:”Without”},{“name”:”Mechanical Durability”,”normalizedValue”:”10,000,000 cycle”,”value”:”10000000 cycles”},{“name”:”Product Certifications”,”normalizedValue”:”CSA, UL, EAC”,”value”:”EAC; UL; CSA”},{“name”:”Rated Operational Voltage Limits”,”normalizedValue”:”38.4 to 52.8 V DC”,”value”:”38.4 to 52.8 V DC”},{“name”:”Operating Rate”,”normalizedValue”:”Less than or Equal to 1200 cycles/hour under load; Less than or Equal to 18000 cycles/hour no-load”,”value”:”Less than or Equal to 1200 cycles/hour under load; Less than or Equal to 18000 cycles/hour no-load”},{“name”:”Drop-Out Voltage Threshold”,”normalizedValue”:”Greater than or Equal to 0.1 Uc DC”,”value”:”Greater than or Equal to 0.1 Uc DC”},{“name”:”Rated Impulse Withstand Voltage”,”normalizedValue”:”4 kV 1.2/50 µs”,”value”:”4 kV 1.2/50 µs”},{“name”:”Utilisation Coefficient”,”normalizedValue”:”0.2″,”value”:”0.2″},{“name”:”Maximum Switching Capacity”,”normalizedValue”:”3750 VA; 420 W”,”value”:”3750 VA; 420 W”},{“name”:”Series Name”,”normalizedValue”:”Power”,”value”:”Power”},{“name”:”Device Presentation”,”normalizedValue”:”complete product”,”value”:”Complete product”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-40 to 131°F”,”value”:”-40 to 131°F (-40 to 55°C)”},{“name”:”Operating Position”,”normalizedValue”:”any position”,”value”:”Any position”},{“name”:”Average Coil Resistance”,”normalizedValue”:”1210 Ohm at 68°F (20°C) +/- 10%”,”value”:”1210 Ohm at 68°F (20°C) +/- 10%”},{“name”:”Vibration Resistance”,”normalizedValue”:”3 gn +/- 1 mm 10 to 150 Hz)5 cycles in operation; 5 gn +/- 1 mm 10 to 150 Hz)5 cycles not operating”,”value”:”3 gn +/- 1 mm 10 to 150 Hz)5 cycles in operation; 5 gn +/- 1 mm 10 to 150 Hz)5 cycles not operating”},{“name”:”Control Circuit Voltage”,”normalizedValue”:”48 V DC”,”value”:”48 V DC”},{“name”:”Conventional Enclosed Thermal Current”,”normalizedValue”:”15 A -40 to 131°F (-40 to 55°C)”,”value”:”15 A -40 to 131°F (-40 to 55°C)”},{“name”:”Electrical Durability”,”normalizedValue”:”100000 cycles resistive”,”value”:”100000 cycles resistive”},{“name”:”Resistive Load Current”,”normalizedValue”:”15 A 250 V AC; 15 A 28 V DC”,”value”:”15 A 250 V AC; 15 A 28 V DC”},{“name”:”Shock Resistance”,”normalizedValue”:”15 gnin operation; 30 gnnot operating”,”value”:”15 gnin operation; 30 gnnot operating”},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”250 V IEC; 300 V CSA; 300 V UL”,”value”:”250 V IEC; 300 V CSA; 300 V UL”},{“name”:”Degree Of Protection”,”normalizedValue”:”IP40 conforming to EN/IEC 60529″,”value”:”IP40 conforming to EN/IEC 60529″},{“name”:”Product Or Component Type”,”normalizedValue”:”Plug-in relay”,”value”:”Plug-in relay”},{“name”:”Pollution Degree”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40 to 185°F”,”value”:”-40 to 185°F (-40 to 85°C)”},{“name”:”Test Levels”,”normalizedValue”:”level A group mounting”,”value”:”Level A group mounting”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Power plug-in relay, 15 A, 4 CO, 48 V DC, 48V DC Coil Volts, 4 C/O”