Power Supply Battery Check Module 20A

$648,99

Power Supply Battery Check Module 20A

9999 in stock

SKU: GRG0862760 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Power Supply Battery Check Module 20A”,”rank”:1,”value”:”Power Supply Battery Check Module 20A”},{“name”:”Depth”,”normalizedValue”:”160 mm”,”value”:”160 mm”},{“name”:”Standards”,”normalizedValue”:”UL 508 || CSA C22.2 No 60950-1″,”value”:”UL 508 || CSA C22.2 No 60950-1″},{“name”:”Input Voltage”,”normalizedValue”:”24 to 28.8 V DC”,”value”:”24 to 28.8 V DC”},{“name”:”Height”,”normalizedValue”:”125 mm”,”value”:”125 mm”},{“name”:”Width”,”normalizedValue”:”60 mm”,”value”:”60 mm”},{“name”:”Current Consumption”,”normalizedValue”:”0.6 A on load || 0.1 mA no load || <= 40.6 A","value":"0.6 A on load || 0.1 mA no load || <= 40.6 A"},{"name":"Relative Humidity","normalizedValue":"0-90 % during operation || 0-95 % during storage","value":"0-90 % during operation || 0-95 % during storage"},{"name":"Connections - Terminals","normalizedValue":"diagnostic relay removable screw terminal block 1 x 0.75 mm² || input connection screw type terminals 2 x 0.5 to 2 x 10 mm² AWG 20 to AWG 8 || output connection screw type terminals 2 x 0.5 to 2 x 10 mm² AWG 20 to AWG 8","value":"diagnostic relay removable screw terminal block 1 x 0.75 mm² || input connection screw type terminals 2 x 0.5 to 2 x 10 mm² AWG 20 to AWG 8 || output connection screw type terminals 2 x 0.5 to 2 x 10 mm² AWG 20 to AWG 8"},{"name":"Local Signalling","normalizedValue":"for alarm status 1 C/O relay || for battery status 1 C/O relay || for power supply status 1 C/O relay || for module status LCD screen","value":"for alarm status 1 C/O relay || for battery status 1 C/O relay || for power supply status 1 C/O relay || for module status LCD screen"},{"name":"Marking","normalizedValue":"CE","value":"CE"},{"name":"Product Or Component Type","normalizedValue":"battery control module","value":"battery control module"},{"name":"Input Voltage Limits","normalizedValue":"22 to 30 V","value":"22 to 30 V"},{"name":"Output Voltage","normalizedValue":"(Ubattery-0.5) V battery mode DC || (Uin-0.25) V nominal mode DC","value":"(Ubattery-0.5) V battery mode DC || (Uin-0.25) V nominal mode DC"},{"name":"Maximum Output Current","normalizedValue":"20 A","value":"20 A"},{"name":"Activation Threshold","normalizedValue":"adjustable 22 to 36 V","value":"adjustable 22 to 36 V"},{"name":"Overvoltage Category","normalizedValue":"class II VDE 0106-1","value":"class II VDE 0106-1"},{"name":"Ambient Air Temperature For Operation","normalizedValue":"-25-60°C","value":"-25-60°C"},{"name":"Environmental Characteristic","normalizedValue":"EMC EN 61000-6-3 || EMC EN/IEC 61000-6-2 || safety EN/IEC 60950-1 || safety EN/IEC 61204-3","value":"EMC EN 61000-6-3 || EMC EN/IEC 61000-6-2 || safety EN/IEC 60950-1 || safety EN/IEC 61204-3"},{"name":"Fixing Mode","normalizedValue":"by clips 35 mm symmetrical DIN rail horizontal || by clips 35 mm symmetrical DIN rail vertical","value":"by clips 35 mm symmetrical DIN rail horizontal || by clips 35 mm symmetrical DIN rail vertical"},{"name":"Mtbf Reliability","normalizedValue":"718708 H at 24 V DC with UTE C80-810 calculation method","value":"718708 H at 24 V DC with UTE C80-810 calculation method"},{"name":"Dielectric Strength","normalizedValue":"500 V between input and ground || 500 V between output and ground","value":"500 V between input and ground || 500 V between output and ground"},{"name":"Operating Altitude","normalizedValue":"6561.68 ft (2000 m)","value":"6561.68 ft (2000 m)"},{"name":"Vibration Resistance","normalizedValue":"2 gn 11.9-150 Hz)EN/IEC 61131-2 || 3.5 mm 3-11.9 Hz)EN/IEC 61131-2","value":"2 gn 11.9-150 Hz)EN/IEC 61131-2 || 3.5 mm 3-11.9 Hz)EN/IEC 61131-2"},{"name":"Number Of Output Channels","normalizedValue":"1","value":"1"},{"name":"Name Of Test","normalizedValue":"electrostatic discharges EN/IEC 61000-4-2 || emission EN 61000-6-3 || induced electromagnetic field EN/IEC 61000-4-6 level 3 || radiated electromagnetic field EN/IEC 61000-4-3 level 3 || rapid transient IEC 61000-4-4 level 3 || surge EN/IEC 61000-4-5 level 2 || conducted/radiated emissions EN 55022 Class B, 20 %","value":"electrostatic discharges EN/IEC 61000-4-2 || emission EN 61000-6-3 || induced electromagnetic field EN/IEC 61000-4-6 level 3 || radiated electromagnetic field EN/IEC 61000-4-3 level 3 || rapid transient IEC 61000-4-4 level 3 || surge EN/IEC 61000-4-5 level 2 || conducted/radiated emissions EN 55022 Class B, 20 %"},{"name":"Ip Degree Of Protection","normalizedValue":"IP20 conforming to EN/IEC 60529","value":"IP20 conforming to EN/IEC 60529"},{"name":"Output Protection Type","normalizedValue":"against overload 1.5 x In || against short-circuits battery-backed mode, automatic reset || against short-circuits power-supplied mode","value":"against overload 1.5 x In || against short-circuits battery-backed mode, automatic reset || against short-circuits power-supplied mode"},{"name":"Product Certifications","normalizedValue":"RCM || EAC","value":"RCM || EAC"},{"name":"Maximum Power Dissipation In W","normalizedValue":"7 W","value":"7 W"},{"name":"Ambient Air Temperature For Storage","normalizedValue":"-40-85°C","value":"-40-85°C"},{"name":"Country of Origin (subject to change)","normalizedValue":"Philippines","value":"Philippines"},{"name":"Package Quantity","normalizedValue":"1","value":"1"}]

Reviews

There are no reviews yet.

Be the first to review “Power Supply Battery Check Module 20A”