Description
[{“name”:”Item”,”normalizedValue”:”Power Supply”,”rank”:2,”value”:”Power Supply”},{“name”:”Input Voltage”,”normalizedValue”:”90/264V AC”,”rank”:3,”value”:”90/264V AC”},{“name”:”Output Power – Rated”,”normalizedValue”:”15 W”,”rank”:5,”value”:”15 W”},{“name”:”Current – Output”,”normalizedValue”:”0.625 A”,”rank”:6,”value”:”0.625 A”},{“name”:”Mounting”,”normalizedValue”:”DIN Rail/Panel”,”rank”:7,”value”:”DIN Rail/Panel”},{“name”:”Housing Material”,”normalizedValue”:”Plastic”,”rank”:8,”value”:”Plastic”},{“name”:”Operating Temp. Range”,”normalizedValue”:”-20 to 55 deg C”,”value”:”-20 to 55°C”},{“name”:”Ripple Volts Regulation”,”normalizedValue”:”Less Than 100mV”,”value”:”Less Than 100mV”},{“name”:”Hold Up Time”,”normalizedValue”:”Greater Than 10 msec @ 115 V AC, Greater Than 60 msec @ 230 V AC”,”value”:”Greater Than 10 msec @ 115 V AC, Greater Than 60 msec @ 230 V AC”},{“name”:”IP Rating”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”Load Regulation”,”normalizedValue”:”Less Than 1%”,”value”:”Less Than 1%”},{“name”:”Depth”,”normalizedValue”:”2.19 in”,”value”:”2.19 in”},{“name”:”Status Indicator”,”normalizedValue”:”Green LED”,”value”:”Green LED”},{“name”:”Protection”,”normalizedValue”:”Overload and Short-Circuits Automatic Reset, Over Temperature Manual Reset , Overvoltage Manual Reset”,”value”:”Overload and Short-Circuits Automatic Reset, Over Temperature Manual Reset , Overvoltage Manual Reset”},{“name”:”Output Voltage”,”normalizedValue”:”24V DC”,”value”:”24V DC”},{“name”:”Connection”,”normalizedValue”:”Screw”,”value”:”Screw”},{“name”:”Width”,”normalizedValue”:”0.71 in”,”value”:”0.71 in”},{“name”:”Output Amps”,”normalizedValue”:”0.625 A”,”value”:”0.625A”},{“name”:”Power Rating”,”normalizedValue”:”15 W”,”value”:”15W”},{“name”:”Height”,”normalizedValue”:”3.58 in”,”value”:”3.58 in”},{“name”:”Case Material”,”normalizedValue”:”Plastic Case”,”value”:”Plastic Case”},{“name”:”Series”,”normalizedValue”:”ABL”,”value”:”ABL”},{“name”:”Style”,”normalizedValue”:”Switching”,”value”:”Switching”},{“name”:”Line Regulation”,”normalizedValue”:”Less Than 0.5%”,”value”:”Less Than 0.5%”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Phase – Electrical”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Features”,”normalizedValue”:”Automatic Reset, It Can Be Directly Connected To Central Distribution Board, The Product Can Be Directly Mounted On The Panel”,”value”:”Automatic Reset, It Can Be Directly Connected To Central Distribution Board, The Product Can Be Directly Mounted On The Panel”},{“name”:”Standards”,”normalizedValue”:”CB Scheme, CE, CSA C22.2 No. 61010-1, CSA C22.2 No. 61010-2-201, CSA C22.2 No. 62368-1, cUL, EN 61010-2-201, EN/IEC 61010-1, EN/IEC 61204-3, EN/IEC 62368-1, IEC 61000-3-2, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3, IEC 61000-6-4, IEC 62368-1, KC, NEC: Class 2, RCM, UL 61010-1, UL 61010-2-201, UL 62368-1″,”value”:”CB Scheme, CE, CSA C22.2 No. 61010-1, CSA C22.2 No. 61010-2-201, CSA C22.2 No. 62368-1, cUL, EN 61010-2-201, EN/IEC 61010-1, EN/IEC 61204-3, EN/IEC 62368-1, IEC 61000-3-2, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3, IEC 61000-6-4, IEC 62368-1, KC, NEC: Class 2, RCM, UL 61010-1, UL 61010-2-201, UL 62368-1″},{“name”:”Power Factor”,”normalizedValue”:”0.51 to 115 V AC, 0.4 to 230 V AC”,”value”:”0.51 at 115 V AC; 0.40 at 230 V AC”},{“name”:”Line And Load Regulation”,”normalizedValue”:”Less than 0.5% network in line; Less than 1% network 0 to 100% load”,”value”:”Less than 0.5% network in line; Less than 1% network 0 to 100% load”},{“name”:”Residual Ripple”,”normalizedValue”:”Less than 100 mV”,”value”:”Less than 100 mV”},{“name”:”Turn-On Time”,”normalizedValue”:”Less than 2 s”,”value”:”Less than 2 s”},{“name”:”Output Coupling”,”normalizedValue”:”serial”,”value”:”Serial”},{“name”:”KW Rating”,”normalizedValue”:”15 W”,”value”:”15 W”},{“name”:”Network System Compatibility”,”normalizedValue”:”TN; TT; IT”,”value”:”TN; TT; IT”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-13 to 131°F (-25 to 55°C) without current derating mounting position A Less than 6561.68 ft (2000 m); 131 to 158°F (55 to 70°C) with current derating of 2.67% per°C mounting position A Less than 6561.68 ft (2000 m)”,”value”:”-13 to 131°F (-25 to 55°C) without current derating mounting position A Less than 6561.68 ft (2000 m); 131 to 158°F (55 to 70°C) with current derating of 2.67% per°C mounting position A Less than 6561.68 ft (2000 m)”},{“name”:”Dielectric Strength”,”normalizedValue”:”3000 V AC input/output”,”value”:”3000 V AC input/output”},{“name”:”Input Protection Type”,”normalizedValue”:”Integrated fuse (not interchangeable) 3.15 A; External protection (recommended) 20 A Curve B; External protection (recommended) 20 A Curve C; External protection (recommended) 2 A Curve B; External protection (recommended) 2 A Curve C”,”value”:”Integrated fuse (not interchangeable) 3.15 A; External protection (recommended) 20 A Curve B; External protection (recommended) 20 A Curve C; External protection (recommended) 2 A Curve B; External protection (recommended) 2 A Curve C”},{“name”:”Output Protection Type”,”normalizedValue”:”Against overload and short-circuits automatic reset; Against over temperature manual reset; Against overvoltage manual reset”,”value”:”Against overload and short-circuits automatic reset; Against over temperature manual reset; Against overvoltage manual reset”},{“name”:”Supply”,”normalizedValue”:”SELV IEC 60950-1; SELV IEC 60204-1; SELV IEC 60364-4-41″,”value”:”SELV IEC 60950-1; SELV IEC 60204-1; SELV IEC 60364-4-41″},{“name”:”Meantime Between Failure”,”normalizedValue”:”3000000 h at 77°F (25°C), full load; 1000000 h at 131°F (55°C), 80% load”,”value”:”3000000 h at 77°F (25°C), full load; 1000000 h at 131°F (55°C), 80% load”},{“name”:”Electromagnetic Emission”,”normalizedValue”:”Conducted emissions IEC 61000-6-3; Radiated emissions IEC 61000-6-4″,”value”:”Conducted emissions IEC 61000-6-3; Radiated emissions IEC 61000-6-4″},{“name”:”Vibration Resistance”,”normalizedValue”:”3 mm 2 to 9 Hz)IEC 60721-3-3; 10 m/s² 9 to 200 Hz)IEC 60721-3-3″,”value”:”3 mm 2 to 9 Hz)IEC 60721-3-3; 10 m/s² 9 to 200 Hz)IEC 60721-3-3″},{“name”:”Current Consumption”,”normalizedValue”:”Less than 0.4 A 115 V AC; Less than 0.25 A 230 V AC”,”value”:”Less than 0.4 A 115 V AC; Less than 0.25 A 230 V AC”},{“name”:”Efficiency”,”normalizedValue”:”81% 115 V AC; 81% 230 V AC”,”value”:”81% 115 V AC; 81% 230 V AC”},{“name”:”Service Life”,”normalizedValue”:”10 year(s)”,”value”:”10 year(s)”},{“name”:”Pollution Degree”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Startup With Capacitive Loads”,”normalizedValue”:”3000 µF”,”value”:”3000 µF”},{“name”:”Power Supply Output Current”,”normalizedValue”:”0.625 A”,”value”:”0.625 A”},{“name”:”Holding Time”,”normalizedValue”:”Greater than 10 ms 115 V AC; Greater than 60 ms 230 V AC”,”value”:”Greater than 10 ms 115 V AC; Greater than 60 ms 230 V AC”},{“name”:”Power Dissipation in W”,”normalizedValue”:”3.5 W”,”value”:”3.5 W”},{“name”:”Electromagnetic Immunity”,”normalizedValue”:”Immunity to electrostatic discharge – test level: 8 kV (contact discharge) conforming to IEC 61000-4-2; Immunity to electrostatic discharge – test level: 15 kV (air discharge) conforming to IEC 61000-4-2; Electromagnetic field immunity test – test level: 15 V/m (80 MHz to 2 GHz) conforming to IEC 61000-4-3; Electromagnetic field immunity test – test level: 5 V/m (2 to 2.7 GHz) conforming to IEC 61000-4-3; Electromagnetic field immunity test – test level: 5 V/m (2.7 to 6 GHz) conforming to IEC 61000-4-3; Immunity to fast transients – test level: 4 kV (on input-output) conforming to IEC 61000-4-4; Surge immunity test – test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5; Surge immunity test – test level: 3 kV (between phases) conforming to IEC 61000-4-5; Immunity to conducted disturbances – test level: 15 V (0.15 to 80 MHz) conforming to IEC 61000-4-6; Immunity to magnetic fields – test level: 30 A/m (50 to 60 Hz) conforming to IEC 61000-4-8; Immunity to voltage dips – test level: 100% (1 cycle) conforming to IEC 61000-4-11; Immunity to voltage dips – test level: 60% (10 cycles) conforming to IEC 61000-4-11; Immunity to voltage dips – test level: 30% (25 cycles) conforming to IEC 61000-4-11; Disturbing field emission conforming to EN 55016-2-3; Limits for harmonic current emissions conforming to IEC 61000-3-2; conforming to EN 55016-1-2; conforming to EN 55016-2-1″,”value”:”Immunity to electrostatic discharge – test level: 8 kV (contact discharge) conforming to IEC 61000-4-2; Immunity to electrostatic discharge – test level: 15 kV (air discharge) conforming to IEC 61000-4-2; Electromagnetic field immunity test – test level: 15 V/m (80 MHz to 2 GHz) conforming to IEC 61000-4-3; Electromagnetic field immunity test – test level: 5 V/m (2 to 2.7 GHz) conforming to IEC 61000-4-3; Electromagnetic field immunity test – test level: 5 V/m (2.7 to 6 GHz) conforming to IEC 61000-4-3; Immunity to fast transients – test level: 4 kV (on input-output) conforming to IEC 61000-4-4; Surge immunity test – test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5; Surge immunity test – test level: 3 kV (between phases) conforming to IEC 61000-4-5; Immunity to conducted disturbances – test level: 15 V (0.15 to 80 MHz) conforming to IEC 61000-4-6; Immunity to magnetic fields – test level: 30 A/m (50 to 60 Hz) conforming to IEC 61000-4-8; Immunity to voltage dips – test level: 100% (1 cycle) conforming to IEC 61000-4-11; Immunity to voltage dips – test level: 60% (10 cycles) conforming to IEC 61000-4-11; Immunity to voltage dips – test level: 30% (25 cycles) conforming to IEC 61000-4-11; Disturbing field emission conforming to EN 55016-2-3; Limits for harmonic current emissions conforming to IEC 61000-3-2; conforming to EN 55016-1-2; conforming to EN 55016-2-1″},{“name”:”Overvoltage Category”,”normalizedValue”:”II”,”value”:”II”},{“name”:”Product Certifications”,”normalizedValue”:”EAC, RCM, CB, CE, CUL Listed, CUL Recognized, KC, NEC class 2, Scheme”,”value”:”CE; CUL Listed; CUL Recognized; RCM; CB Scheme; EAC; KC; NEC class 2″},{“name”:”Maximum Leakage Current”,”normalizedValue”:”0.25 mA 240 V AC”,”value”:”0.25 mA 240 V AC”},{“name”:”Operating Altitude”,”normalizedValue”:”Less than 6561.68 ft (2000 m) overvoltage category III; 2000 m to 5000 m overvoltage category II”,”value”:”Less than 6561.68 ft (2000 m) overvoltage category III; 2000 m to 5000 m overvoltage category II”},{“name”:”Shock Resistance”,”normalizedValue”:”150 m/s² 11 ms”,”value”:”150 m/s² 11 ms”},{“name”:”Inrush Current”,”normalizedValue”:”15 A 115 V; 30 A 230 V”,”value”:”15 A 115 V; 30 A 230 V”},{“name”:”Electrical Shock Protection Class”,”normalizedValue”:”class II without PE connection”,”value”:”Class II without PE connection”},{“name”:”Current – Inrush”,”normalizedValue”:”30 A”,”value”:”30 A”},{“name”:”Maximum Efficiency @ 115V AC”,”normalizedValue”:”81%”,”value”:”81 %”},{“name”:”Mean Time Between Failures (MTBF)”,”normalizedValue”:”3,000,000 hr”,”value”:”3,000,000 hr”},{“name”:”Wire Size – Minimum”,”normalizedValue”:”20 AWG”,”value”:”20 AWG”},{“name”:”Input Frequency – Nominal”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”158 deg F”,”value”:”158 Degrees F”},{“name”:”Maximum Efficiency @ 230V AC”,”normalizedValue”:”81%”,”value”:”81 %”},{“name”:”Wire Connection Type”,”normalizedValue”:”Terminals”,”value”:”Screw Terminals”},{“name”:”Wire Size – Maximum”,”normalizedValue”:”16 AWG”,”value”:”16 AWG”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”-13 deg F”,”value”:”-13 Degrees F”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”India”,”value”:”India”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.