Power Supply, 100 to 240V AC, 24 V DC, 60W, 2.5A, DIN Rail

$185,99

POWER SUPPLY 24V 2.5A MODULAR

9999 in stock

SKU: GRG910839209 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Power Supply”,”rank”:2,”value”:”Power Supply”},{“name”:”Input Voltage”,”normalizedValue”:”100 to 240V AC”,”rank”:3,”value”:”100 to 240V AC”},{“name”:”Mounting”,”normalizedValue”:”DIN Rail”,”rank”:7,”value”:”DIN Rail”},{“name”:”IP Rating”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”Case Material”,”normalizedValue”:”Plastic Case”,”value”:”Plastic Case”},{“name”:”Style”,”normalizedValue”:”Regulated Switch”,”value”:”Regulated Switch”},{“name”:”Height”,”normalizedValue”:”91 mm”,”value”:”91 mm”},{“name”:”Depth”,”normalizedValue”:”55.6 mm”,”value”:”55.6 mm”},{“name”:”Output Voltage”,”normalizedValue”:”24 V DC”,”value”:”24 V DC”},{“name”:”Power Rating”,”normalizedValue”:”60 W”,”value”:”60W”},{“name”:”Output Amps”,”normalizedValue”:”2.5 A”,”value”:”2.5A”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Connection”,”normalizedValue”:”Screw”,”value”:”Screw”},{“name”:”Phase – Electrical”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Standards”,”normalizedValue”:”IEC 62368-1, EN/IEC 61010-1, EN 61010-2-201, EN/IEC 61204-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3, IEC 61000-6-4, IEC 61000-3-2, EN 61000-3-3, UL 62368-1, UL 61010-1, UL 61010-2-201, CSA C22.2 No 62368-1, CSA C22.2 No 61010-1, CSA C22.2 No 61010-2-201, EN/IEC 62368-1″,”value”:”IEC 62368-1, EN/IEC 61010-1, EN 61010-2-201, EN/IEC 61204-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3, IEC 61000-6-4, IEC 61000-3-2, EN 61000-3-3, UL 62368-1, UL 61010-1, UL 61010-2-201, CSA C22.2 No 62368-1, CSA C22.2 No 61010-1, CSA C22.2 No 61010-2-201, EN/IEC 62368-1″},{“name”:”Status Indicator”,”normalizedValue”:”Green LED”,”value”:”Green LED”},{“name”:”Width”,”normalizedValue”:”53 mm”,”value”:”53 mm”},{“name”:”Power Dissipation In W”,”normalizedValue”:”6.5 W”,”value”:”6.5 W”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-25–10°C with current derating of 1 % per°C mounting position A < 6561.68 ft (2000 m), -10-55°C without current derating mounting position A < 6561.68 ft (2000 m), 55-70°C with current derating of 2.67 % per°C mounting position A < 6561.68 ft (2000 m)","value":"-25--10°C with current derating of 1 % per°C mounting position A < 6561.68 ft (2000 m), -10-55°C without current derating mounting position A < 6561.68 ft (2000 m), 55-70°C with current derating of 2.67 % per°C mounting position A < 6561.68 ft (2000 m)"},{"name":"Inrush Current","normalizedValue":"30 A 115 V, 60 A 230 V","value":"30 A 115 V, 60 A 230 V"},{"name":"Network Frequency Limits","normalizedValue":"50-60 Hz","value":"50-60 Hz"},{"name":"Shock Resistance","normalizedValue":"150 m/s² 11 ms","value":"150 m/s² 11 ms"},{"name":"Meantime Between Failure [Mtbf]","normalizedValue":"1300000 h at 25°C, full load, 700000 h at 55°C, 80 % load","value":"1300000 h at 25°C, full load, 700000 h at 55°C, 80 % load"},{"name":"Mounting Support","normalizedValue":"top hat type TH35-15 rail IEC 60715, top hat type TH35-7.5 rail IEC 60715, double-profile DIN rail, panel mounting","value":"top hat type TH35-15 rail IEC 60715, top hat type TH35-7.5 rail IEC 60715, double-profile DIN rail, panel mounting"},{"name":"Load Capacitance","normalizedValue":"3,000µF","value":"3000µF"},{"name":"Dielectric Strength","normalizedValue":"3000 V AC input/output","value":"3000 V AC input/output"},{"name":"Range of Product","normalizedValue":"Modicon Power Supply","value":"Modicon Power Supply"},{"name":"Electromagnetic Compatibility","normalizedValue":"immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2, immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2, electromagnetic field immunity test - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3, electromagnetic field immunity test - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3, electromagnetic field immunity test - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3, immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4, surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5, surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5, immunity to conducted disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6, immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8, immunity to voltage dips - test level: 100 % (1 cycle) conforming to IEC 61000-4-11, immunity to voltage dips - test level: 60 % (10 cycles) conforming to IEC 61000-4-11, immunity to voltage dips - test level: 30 % (25 cycles) conforming to IEC 61000-4-11, disturbing field emission conforming to EN 55016-2-3, limits for harmonic current emissions conforming to IEC 61000-3-2, conforming to EN 55016-1-2, conforming to EN 55016-2-1","value":"immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2, immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2, electromagnetic field immunity test - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3, electromagnetic field immunity test - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3, electromagnetic field immunity test - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3, immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4, surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5, surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5, immunity to conducted disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6, immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8, immunity to voltage dips - test level: 100 % (1 cycle) conforming to IEC 61000-4-11, immunity to voltage dips - test level: 60 % (10 cycles) conforming to IEC 61000-4-11, immunity to voltage dips - test level: 30 % (25 cycles) conforming to IEC 61000-4-11, disturbing field emission conforming to EN 55016-2-3, limits for harmonic current emissions conforming to IEC 61000-3-2, conforming to EN 55016-1-2, conforming to EN 55016-2-1"},{"name":"Service Life","normalizedValue":"10 year(s)","value":"10 year(s)"},{"name":"Residual Ripple","normalizedValue":"< 100 mV","value":"< 100 mV"},{"name":"Overvoltage Category","normalizedValue":"II","value":"II"},{"name":"Maximum Leakage Current","normalizedValue":"0.25 mA 240 V AC","value":"0.25 mA 240 V AC"},{"name":"Output Coupling","normalizedValue":"serial","value":"serial, parallel"},{"name":"Electromagnetic Emission","normalizedValue":"conducted emissions IEC 61000-6-3, radiated emissions IEC 61000-6-4","value":"conducted emissions IEC 61000-6-3, radiated emissions IEC 61000-6-4"},{"name":"Holding Time","normalizedValue":"> 20 ms 115 V AC, > 60 ms 230 V AC”,”value”:”> 20 ms 115 V AC, > 60 ms 230 V AC”},{“name”:”Efficiency At Full Load”,”normalizedValue”:”90…264 V AC”,”value”:”90…264 V AC”},{“name”:”Electrical Shock Protection Class”,”normalizedValue”:”class II without PE connection”,”value”:”class II without PE connection”},{“name”:”Power Supply Output Current”,”normalizedValue”:”2.5 A”,”value”:”2.5 A”},{“name”:”Pollution Degree”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Efficiency”,”normalizedValue”:”90 % 115 V AC, 90 % 230 V AC”,”value”:”90 % 115 V AC, 90 % 230 V AC”},{“name”:”Kw Rating”,”normalizedValue”:”60 W”,”value”:”60 W”},{“name”:”Power Factor”,”normalizedValue”:”0.5 to 115 V AC, 0.39 to 230 V AC”,”value”:”0.50 at 115 V AC, 0.39 at 230 V AC”},{“name”:”Output Protection Type”,”normalizedValue”:”against overload and short-circuits automatic reset, against over temperature manual reset, against overvoltage manual reset”,”value”:”against overload and short-circuits automatic reset, against over temperature manual reset, against overvoltage manual reset”},{“name”:”Supply”,”normalizedValue”:”SELV IEC 60950-1, SELV IEC 60204-1, SELV IEC 60364-4-41″,”value”:”SELV IEC 60950-1, SELV IEC 60204-1, SELV IEC 60364-4-41″},{“name”:”Operating Altitude”,”normalizedValue”:”< 6561.68 ft (2000 m) overvoltage category III, 2000 m...5000 m overvoltage category II","value":"< 6561.68 ft (2000 m) overvoltage category III, 2000 m...5000 m overvoltage category II"},{"name":"Response Time","normalizedValue":"< 2 sec","value":"< 2 s"},{"name":"Vibration Resistance","normalizedValue":"3 mm 2-9 Hz)IEC 60721-3-3, 10 m/s² 9-200 Hz)IEC 60721-3-3","value":"3 mm 2-9 Hz)IEC 60721-3-3, 10 m/s² 9-200 Hz)IEC 60721-3-3"},{"name":"Input Protection Type","normalizedValue":"integrated fuse (not interchangeable) 3.15 A, external protection (recommended) 20 A Curve B, external protection (recommended) 20 A Curve C, external protection (recommended) 10 A Curve B, external protection (recommended) 6 A Curve C","value":"integrated fuse (not interchangeable) 3.15 A, external protection (recommended) 20 A Curve B, external protection (recommended) 20 A Curve C, external protection (recommended) 10 A Curve B, external protection (recommended) 6 A Curve C"},{"name":"Line And Load Regulation","normalizedValue":"< 0.5 % network in line, < 1 % network 0 to 100 % load","value":"< 0.5 % network in line, < 1 % network 0 to 100 % load"},{"name":"Current Consumption","normalizedValue":"< 1.5 A 115 V AC, < 1 A 230 V AC","value":"< 1.5 A 115 V AC, < 1 A 230 V AC"},{"name":"Earthing System","normalizedValue":"TN, TT, IT","value":"TN, TT, IT"},{"name":"Country of Origin (subject to change)","normalizedValue":"Thailand","value":"Thailand"},{"name":"Package Quantity","normalizedValue":"1","value":"1"}]

Reviews

There are no reviews yet.

Be the first to review “Power Supply, 100 to 240V AC, 24 V DC, 60W, 2.5A, DIN Rail”