Description
[{“name”:”Item”,”normalizedValue”:”Power Supply”,”rank”:2,”value”:”Power Supply”},{“name”:”Input Voltage”,”normalizedValue”:”100 to 240V AC”,”rank”:3,”value”:”100 to 240V AC”},{“name”:”Mounting”,”normalizedValue”:”DIN Rail”,”rank”:7,”value”:”DIN Rail”},{“name”:”Standards”,”normalizedValue”:”IEC 62368-1, EN/IEC 61010-1, EN 61010-2-201, EN/IEC 61204-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3, IEC 61000-6-4, IEC 61000-3-2, EN 61000-3-3, UL 62368-1, UL 61010-1, UL 61010-2-201, CSA C22.2 No 62368-1, CSA C22.2 No 61010-1, CSA C22.2 No 61010-2-201, EN/IEC 62368-1″,”value”:”IEC 62368-1, EN/IEC 61010-1, EN 61010-2-201, EN/IEC 61204-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3, IEC 61000-6-4, IEC 61000-3-2, EN 61000-3-3, UL 62368-1, UL 61010-1, UL 61010-2-201, CSA C22.2 No 62368-1, CSA C22.2 No 61010-1, CSA C22.2 No 61010-2-201, EN/IEC 62368-1″},{“name”:”Style”,”normalizedValue”:”Regulated Switch”,”value”:”Regulated Switch”},{“name”:”Height”,”normalizedValue”:”123.6 mm”,”value”:”123.6 mm”},{“name”:”Connection”,”normalizedValue”:”Screw”,”value”:”Screw”},{“name”:”Case Material”,”normalizedValue”:”Aluminum Case”,”value”:”Aluminum Case”},{“name”:”Depth”,”normalizedValue”:”128.5 mm”,”value”:”128.5 mm”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”IP Rating”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”Phase – Electrical”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Status Indicator”,”normalizedValue”:”Green LED”,”value”:”Green LED”},{“name”:”Output Voltage”,”normalizedValue”:”24 V DC”,”value”:”24 V DC”},{“name”:”Output Amps”,”normalizedValue”:”20 A”,”value”:”20A”},{“name”:”Width”,”normalizedValue”:”85.5 mm”,”value”:”85.5 mm”},{“name”:”Power Rating”,”normalizedValue”:”480 W”,”value”:”480W”},{“name”:”Pollution Degree”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Input Protection Type”,”normalizedValue”:”integrated fuse (not interchangeable) 10 A, external protection (recommended) 20 A Curve C, external protection (recommended) 16 A Curve B, external protection (recommended) 13 A Curve C”,”value”:”integrated fuse (not interchangeable) 10 A, external protection (recommended) 20 A Curve C, external protection (recommended) 16 A Curve B, external protection (recommended) 13 A Curve C”},{“name”:”Network Frequency Limits”,”normalizedValue”:”50-60 Hz”,”value”:”50-60 Hz”},{“name”:”Output Protection Type”,”normalizedValue”:”against overload and short-circuits automatic reset, against over temperature manual reset, against overvoltage manual reset”,”value”:”against overload and short-circuits automatic reset, against over temperature manual reset, against overvoltage manual reset”},{“name”:”Holding Time”,”normalizedValue”:”\u003e 20 ms 115 V AC, \u003e 20 ms 230 V AC”,”value”:”\u003e 20 ms 115 V AC, \u003e 20 ms 230 V AC”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-20-40°C without derating mounting position A 115 V AC \u003c 6561.68 ft (2000 m), -20-50°C without derating mounting position A 230 V AC \u003c 6561.68 ft (2000 m), 40-70°C with current derating of 1.67 % per°C mounting position A 115 V AC \u003c 6561.68 ft (2000 m), 50-70°C with current derating of 2.5 % per°C mounting position A 230 V AC \u003c 6561.68 ft (2000 m)”,”value”:”-20-40°C without derating mounting position A 115 V AC \u003c 6561.68 ft (2000 m), -20-50°C without derating mounting position A 230 V AC \u003c 6561.68 ft (2000 m), 40-70°C with current derating of 1.67 % per°C mounting position A 115 V AC \u003c 6561.68 ft (2000 m), 50-70°C with current derating of 2.5 % per°C mounting position A 230 V AC \u003c 6561.68 ft (2000 m)”},{“name”:”Inrush Current”,”normalizedValue”:”45.0 A 115 V, 90.0 A 230 V”,”value”:”45.0 A 115 V, 90.0 A 230 V”},{“name”:”Line And Load Regulation”,”normalizedValue”:”\u003c 0.5 % network 0 to 100 % load at 25°C, \u003c 1 % network full voltage range in line at 25°C”,”value”:”\u003c 0.5 % network 0 to 100 % load at 25°C, \u003c 1 % network full voltage range in line at 25°C”},{“name”:”Vibration Resistance”,”normalizedValue”:”3 mm 2-9 Hz)IEC 60068-2-6, 10 m/s² 9-200 Hz)IEC 60068-2-6″,”value”:”3 mm 2-9 Hz)IEC 60068-2-6, 10 m/s² 9-200 Hz)IEC 60068-2-6″},{“name”:”Load Capacitance”,”normalizedValue”:”8,000µF”,”value”:”8000µF”},{“name”:”Electrical Shock Protection Class”,”normalizedValue”:”class I”,”value”:”class I”},{“name”:”Output Coupling”,”normalizedValue”:”serial, parallel”,”value”:”parallel, serial”},{“name”:”Electromagnetic Emission”,”normalizedValue”:”conducted emissions IEC 61000-6-3, radiated emissions IEC 61000-6-4″,”value”:”conducted emissions IEC 61000-6-3, radiated emissions IEC 61000-6-4″},{“name”:”Power Supply Output Current”,”normalizedValue”:”20 A”,”value”:”20 A”},{“name”:”Residual Ripple”,”normalizedValue”:”\u003c 120 mV”,”value”:”\u003c 120 mV”},{“name”:”Meantime Between Failure [Mtbf]”,”normalizedValue”:”700000 h at 25°C, full load conforming to SR 332″,”value”:”700000 h at 25°C, full load conforming to SR 332″},{“name”:”Efficiency At Full Load”,”normalizedValue”:”85…264 V AC without temperature derating, 120…375 V DC without temperature derating”,”value”:”85…264 V AC without temperature derating, 120…375 V DC without temperature derating”},{“name”:”Earthing System”,”normalizedValue”:”TN, TT, IT”,”value”:”TN, TT, IT”},{“name”:”Current Consumption”,”normalizedValue”:”\u003c 5.4 A 115 V AC, \u003c 2.7 A 230 V AC, \u003c 5 A 140 V DC”,”value”:”\u003c 5.4 A 115 V AC, \u003c 2.7 A 230 V AC, \u003c 5 A 140 V DC”},{“name”:”Operating Altitude”,”normalizedValue”:”\u003c 5000 m”,”value”:”\u003c 5000 m”},{“name”:”Electromagnetic Compatibility”,”normalizedValue”:”immunity to electrostatic discharge – test level: 8 kV (contact discharge) conforming to IEC 61000-4-2, immunity to electrostatic discharge – test level: 15 kV (air discharge) conforming to IEC 61000-4-2, immunity to conducted RF disturbances – test level: 15 V/m (80 MHz…2 GHz) conforming to IEC 61000-4-3, immunity to conducted RF disturbances – test level: 5 V/m (2…2.7 GHz) conforming to IEC 61000-4-3, immunity to conducted RF disturbances – test level: 5 V/m (2.7…6 GHz) conforming to IEC 61000-4-3, immunity to fast transients – test level: 4 kV (on input-output) conforming to IEC 61000-4-4, surge immunity test – test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5, surge immunity test – test level: 3 kV (between phases) conforming to IEC 61000-4-5, immunity to conducted RF disturbances – test level: 15 V (0.15…80 MHz) conforming to IEC 61000-4-6, immunity to magnetic fields – test level: 30 A/m (50…60 Hz) conforming to IEC 61000-4-8, immunity to voltage dips conforming to IEC 61000-4-11, disturbing field emission conforming to EN 55016-2-3, limits for harmonic current emissions conforming to IEC 61000-3-2, conforming to EN 55016-1-2, conforming to EN 55016-2-1″,”value”:”immunity to electrostatic discharge – test level: 8 kV (contact discharge) conforming to IEC 61000-4-2, immunity to electrostatic discharge – test level: 15 kV (air discharge) conforming to IEC 61000-4-2, immunity to conducted RF disturbances – test level: 15 V/m (80 MHz…2 GHz) conforming to IEC 61000-4-3, immunity to conducted RF disturbances – test level: 5 V/m (2…2.7 GHz) conforming to IEC 61000-4-3, immunity to conducted RF disturbances – test level: 5 V/m (2.7…6 GHz) conforming to IEC 61000-4-3, immunity to fast transients – test level: 4 kV (on input-output) conforming to IEC 61000-4-4, surge immunity test – test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5, surge immunity test – test level: 3 kV (between phases) conforming to IEC 61000-4-5, immunity to conducted RF disturbances – test level: 15 V (0.15…80 MHz) conforming to IEC 61000-4-6, immunity to magnetic fields – test level: 30 A/m (50…60 Hz) conforming to IEC 61000-4-8, immunity to voltage dips conforming to IEC 61000-4-11, disturbing field emission conforming to EN 55016-2-3, limits for harmonic current emissions conforming to IEC 61000-3-2, conforming to EN 55016-1-2, conforming to EN 55016-2-1″},{“name”:”Maximum Leakage Current”,”normalizedValue”:”1 mA 240 V AC”,”value”:”1 mA 240 V AC”},{“name”:”Power Factor”,”normalizedValue”:”0.95 to 115 V AC, 0.95 to 230 V AC”,”value”:”0.95 at 115 V AC, 0.95 at 230 V AC”},{“name”:”Power Dissipation In W”,”normalizedValue”:”60 W”,”value”:”60 W”},{“name”:”Efficiency”,”normalizedValue”:”85 % 115 V AC, 88 % 230 V AC”,”value”:”85 % 115 V AC, 88 % 230 V AC”},{“name”:”Shock Resistance”,”normalizedValue”:”150 m/s² 11 ms”,”value”:”150 m/s² 11 ms”},{“name”:”Kw Rating”,”normalizedValue”:”480 W”,”value”:”480 W”},{“name”:”Supply”,”normalizedValue”:”SELV IEC 60950-1, SELV IEC 60204-1, SELV IEC 60364-4-41″,”value”:”SELV IEC 60950-1, SELV IEC 60204-1, SELV IEC 60364-4-41″},{“name”:”Response Time”,”normalizedValue”:”\u003c 1.5 sec”,”value”:”\u003c 1.5 s”},{“name”:”Dielectric Strength”,”normalizedValue”:”3000 V AC with input to output”,”value”:”3000 V AC with input to output”},{“name”:”Range of Product”,”normalizedValue”:”Modicon Power Supply”,”value”:”Modicon Power Supply”},{“name”:”Mounting Support”,”normalizedValue”:”top hat type TH35-15 rail IEC 60715, top hat type TH35-7.5 rail IEC 60715, double-profile DIN rail”,”value”:”top hat type TH35-15 rail IEC 60715, top hat type TH35-7.5 rail IEC 60715, double-profile DIN rail”},{“name”:”Service Life”,”normalizedValue”:”10 year(s)”,”value”:”10 year(s)”},{“name”:”Overvoltage Category”,”normalizedValue”:”II”,”value”:”II”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”India”,”value”:”India”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.