Power Supply, 100 to 240V AC, 24 V DC, 240W, 10A, Panel

$203,99

Regulated Power Supply, modicon power supply, 100…240V AC, 24V, 10A, single phase, Panel Mount

9999 in stock

SKU: GRG210839145 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Power Supply”,”rank”:2,”value”:”Power Supply”},{“name”:”Input Voltage”,”normalizedValue”:”100 to 240V AC”,”rank”:3,”value”:”100 to 240V AC”},{“name”:”Mounting”,”normalizedValue”:”Panel”,”rank”:7,”value”:”Panel”},{“name”:”Width”,”normalizedValue”:”93 mm”,”value”:”93 mm”},{“name”:”IP Rating”,”normalizedValue”:”IP10″,”value”:”IP10″},{“name”:”Output Amps”,”normalizedValue”:”10 A”,”value”:”10A”},{“name”:”Style”,”normalizedValue”:”Regulated Switch”,”value”:”Regulated Switch”},{“name”:”Connection”,”normalizedValue”:”Screw”,”value”:”Screw”},{“name”:”Power Rating”,”normalizedValue”:”240 W”,”value”:”240W”},{“name”:”Height”,”normalizedValue”:”50 mm”,”value”:”50 mm”},{“name”:”Case Material”,”normalizedValue”:”Aluminum Case”,”value”:”Aluminum Case”},{“name”:”Depth”,”normalizedValue”:”190 mm”,”value”:”190 mm”},{“name”:”Status Indicator”,”normalizedValue”:”Green LED”,”value”:”Green LED”},{“name”:”Phase – Electrical”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Output Voltage”,”normalizedValue”:”24 V DC”,”value”:”24 V DC”},{“name”:”Standards”,”normalizedValue”:”IEC 62368-1, EN/IEC 61010-1, EN 61010-2-201, EN/IEC 61204-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3, IEC 61000-6-4, IEC 61000-3-2, EN 61000-3-3, UL 62368-1, UL 61010-1, UL 61010-2-201, CSA C22.2 No 62368-1, CSA C22.2 No 61010-1, CSA C22.2 No 61010-2-201, IEC 60335-1, EN/IEC 62368-1″,”value”:”IEC 62368-1, EN/IEC 61010-1, EN 61010-2-201, EN/IEC 61204-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3, IEC 61000-6-4, IEC 61000-3-2, EN 61000-3-3, UL 62368-1, UL 61010-1, UL 61010-2-201, CSA C22.2 No 62368-1, CSA C22.2 No 61010-1, CSA C22.2 No 61010-2-201, IEC 60335-1, EN/IEC 62368-1″},{“name”:”Overvoltage Category”,”normalizedValue”:”II”,”value”:”II”},{“name”:”Kw Rating”,”normalizedValue”:”240 W”,”value”:”240 W”},{“name”:”Operating Altitude”,”normalizedValue”:”5000 m”,”value”:”5000 m”},{“name”:”Efficiency At Full Load”,”normalizedValue”:”85…264 V AC”,”value”:”85…264 V AC”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-10-50°C without derating mounting position A, B, C, D, F, G < 6561.68 ft (2000 m), 50-70°C with current derating of 2.5 % per°C mounting position A, B, C, D, F, G < 6561.68 ft (2000 m), 50-70°C with current derating of 2.5 % per°C < 6561.68 ft (2000 m)","value":"-10-50°C without derating mounting position A, B, C, D, F, G < 6561.68 ft (2000 m), 50-70°C with current derating of 2.5 % per°C mounting position A, B, C, D, F, G < 6561.68 ft (2000 m), 50-70°C with current derating of 2.5 % per°C < 6561.68 ft (2000 m)"},{"name":"Response Time","normalizedValue":"< 1.2 sec","value":"< 1.2 s"},{"name":"Earthing System","normalizedValue":"TN, TT, IT","value":"TN, TT, IT"},{"name":"Inrush Current","normalizedValue":"35 A 115 V, 60 A 230 V","value":"35 A 115 V, 60 A 230 V"},{"name":"Electrical Shock Protection Class","normalizedValue":"class I","value":"class I"},{"name":"Range of Product","normalizedValue":"Modicon Power Supply","value":"Modicon Power Supply"},{"name":"Meantime Between Failure [Mtbf]","normalizedValue":"700000 h at 25°C, full load conforming to SR 332","value":"700000 h at 25°C, full load conforming to SR 332"},{"name":"Mounting Support","normalizedValue":"top hat type TH35-15 rail IEC 60715, top hat type TH35-7.5 rail IEC 60715, double-profile DIN rail, panel mounting","value":"top hat type TH35-15 rail IEC 60715, top hat type TH35-7.5 rail IEC 60715, double-profile DIN rail, panel mounting"},{"name":"Power Supply Output Current","normalizedValue":"10 A","value":"10A"},{"name":"Efficiency","normalizedValue":"87 % 230 V AC","value":"87 % 230 V AC"},{"name":"Input Protection Type","normalizedValue":"integrated fuse (not interchangeable) 6.3 A","value":"integrated fuse (not interchangeable) 6.3 A"},{"name":"Residual Ripple","normalizedValue":"< 150 mV","value":"< 150 mV"},{"name":"Maximum Leakage Current","normalizedValue":"1 mA 240 V AC","value":"1 mA 240 V AC"},{"name":"Supply","normalizedValue":"SELV IEC 60950-1, SELV IEC 60204-1, SELV IEC 60364-4-41","value":"SELV IEC 60950-1, SELV IEC 60204-1, SELV IEC 60364-4-41"},{"name":"Service Life","normalizedValue":"10 year(s)","value":"10 year(s)"},{"name":"Vibration Resistance","normalizedValue":"3 mm 2-9 Hz)IEC 60068-2-6, 10 m/s² 9-200 Hz)IEC 60068-2-6","value":"3 mm 2-9 Hz)IEC 60068-2-6, 10 m/s² 9-200 Hz)IEC 60068-2-6"},{"name":"Dielectric Strength","normalizedValue":"3000 V AC with input to output","value":"3000 V AC with input to output"},{"name":"Load Capacitance","normalizedValue":"8,000µF","value":"8000µF"},{"name":"Network Frequency Limits","normalizedValue":"50-60 Hz","value":"50-60 Hz"},{"name":"Electromagnetic Emission","normalizedValue":"conducted emissions IEC 61000-6-3, radiated emissions IEC 61000-6-4","value":"conducted emissions IEC 61000-6-3, radiated emissions IEC 61000-6-4"},{"name":"Power Factor","normalizedValue":"0.95 to 115 V AC, 0.91 to 230 V AC","value":"0.95 at 115 V AC, 0.91 at 230 V AC"},{"name":"Line And Load Regulation","normalizedValue":"< 0.5 % network 0 to 100 % load at 25°C, < 1 % network full voltage range in line at 25°C","value":"< 0.5 % network 0 to 100 % load at 25°C, < 1 % network full voltage range in line at 25°C"},{"name":"Output Coupling","normalizedValue":"serial, parallel","value":"parallel, serial"},{"name":"Holding Time","normalizedValue":"> 20 ms 115 V AC, > 40 ms 230 V AC”,”value”:”> 20 ms 115 V AC, > 40 ms 230 V AC”},{“name”:”Current Consumption”,”normalizedValue”:”< 3.6 A 115 V AC, < 1.8 A 230 V AC","value":"< 3.6 A 115 V AC, < 1.8 A 230 V AC"},{"name":"Electromagnetic Compatibility","normalizedValue":"immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2, immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2, immunity to conducted RF disturbances - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3, immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3, immunity to conducted RF disturbances - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3, immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4, surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5, surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5, immunity to conducted RF disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6, immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8, immunity to voltage dips conforming to IEC 61000-4-11, disturbing field emission conforming to EN 55016-2-3, limits for harmonic current emissions conforming to IEC 61000-3-2, conforming to EN 55016-1-2, conforming to EN 55016-2-1","value":"immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2, immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2, immunity to conducted RF disturbances - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3, immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3, immunity to conducted RF disturbances - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3, immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4, surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5, surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5, immunity to conducted RF disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6, immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8, immunity to voltage dips conforming to IEC 61000-4-11, disturbing field emission conforming to EN 55016-2-3, limits for harmonic current emissions conforming to IEC 61000-3-2, conforming to EN 55016-1-2, conforming to EN 55016-2-1"},{"name":"Output Protection Type","normalizedValue":"against overload and short-circuits automatic reset, against over temperature manual reset, against overvoltage manual reset","value":"against overload and short-circuits automatic reset, against over temperature manual reset, against overvoltage manual reset"},{"name":"Power Dissipation In W","normalizedValue":"36 W","value":"36 W"},{"name":"Pollution Degree","normalizedValue":"2","value":"2"},{"name":"Shock Resistance","normalizedValue":"150 m/s² 11 ms","value":"150 m/s² 11 ms"},{"name":"Country of Origin (subject to change)","normalizedValue":"Canada","value":"Canada"},{"name":"Package Quantity","normalizedValue":"1","value":"1"}]

Reviews

There are no reviews yet.

Be the first to review “Power Supply, 100 to 240V AC, 24 V DC, 240W, 10A, Panel”