Description
[{“name”:”Item”,”normalizedValue”:”Power Strip”,”rank”:1,”value”:”Power Strip”},{“name”:”Type”,”normalizedValue”:”Vertical Basic”,”rank”:2,”value”:”Vertical Basic”},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-20R”,”rank”:4,”value”:”5-20R”},{“name”:”Plug Configuration”,”normalizedValue”:”5-20P”,”rank”:5,”value”:”5-20P”},{“name”:”Cord Length”,”normalizedValue”:”15 ft”,”rank”:6,”value”:”15 ft.”},{“name”:”Color”,”normalizedValue”:”Natural”,”rank”:7,”value”:”Natural”},{“name”:”Gauge/Conductor”,”normalizedValue”:”4″,”rank”:8,”value”:”12/3″},{“name”:”Standards”,”normalizedValue”:”TAA-Compliant, RoHS/REACH Compliant”,”rank”:9,”value”:”TAA-Compliant, RoHS/REACH Compliant”},{“name”:”Voltage”,”normalizedValue”:”120 VAC”,”value”:”120 VAC”},{“name”:”Metered”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”7″,”value”:”7″},{“name”:”Features”,”normalizedValue”:”Low-profile slim design constructed of rugged light weight aluminum; Designed for a variety of applications, specifically where electromagnetic or radio frequency interference is a concern: Shielded cord reduces EMI/ RFI and \”dirty\” power from utilities. Shielding is by way of 100% coverage in aluminum mylar foil with a 20 gauge drain wire; Shielded cord reduces EMI/ RFI and \”dirty\” power from utilities; Shielding is by way of 100% coverage in aluminum mylar foil with a 20 gauge drain wire; Each outlet strip includes a hardware mounting kit. Order P/N: 1585CLIP for additional hardware kit; Includes toolless PDU button mounting provision; Receptacles are 1\” square and are equally spaced over the length of the power strip; With on/off switch and 15 or 20 Amp circuit breaker.”,”value”:”Low-profile slim design constructed of rugged light weight aluminum; Designed for a variety of applications, specifically where electromagnetic or radio frequency interference is a concern: Shielded cord reduces EMI/ RFI and \”dirty\” power from utilities. Shielding is by way of 100% coverage in aluminum mylar foil with a 20 gauge drain wire; Shielded cord reduces EMI/ RFI and \”dirty\” power from utilities; Shielding is by way of 100% coverage in aluminum mylar foil with a 20 gauge drain wire; Each outlet strip includes a hardware mounting kit. Order P/N: 1585CLIP for additional hardware kit; Includes toolless PDU button mounting provision; Receptacles are 1\” square and are equally spaced over the length of the power strip; With on/off switch and 15 or 20 Amp circuit breaker.”},{“name”:”Total Outlets”,”normalizedValue”:”7″,”value”:”7″},{“name”:”Outlet Type”,”normalizedValue”:”5-20R”,”value”:”5-20R”},{“name”:”Shielded Cord”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Outlets (Rear)”,”normalizedValue”:”0″,”value”:”0″},{“name”:”Outlet Strip Type”,”normalizedValue”:”Vertical Basic PDU”,”value”:”Vertical Basic PDU”},{“name”:”Rotated Outlets”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Cord Included”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Switch Type”,”normalizedValue”:”On/Off Rocker Switch”,”value”:”On/Off Rocker Switch”},{“name”:”Hospital Grade”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Specifications”,”normalizedValue”:”Heavy duty cord, either 12 gauge (12/3 SJT) or 14 gauge (14/3 SJT) wire for extreme temperature ranges and integral molded plug; Plug types for 15 Amp models are NEMA 5-15P straight blade or NEMA L5-15P locking type; Plug types for 20 Amp models are NEMA 5-20P straight blade or NEMA L5-20P locking type; Rated 15 or 20 amps, 120 volts; UL/cUL Listed Standard UL1363 file No. E166039 & CSA C22.2 No. 308-14 & CSA C22.2 No. 0.4-04; NOTE #1: Outlet strips can NOT be used between the front & rear panel rails of rack cabinets as they (and the equipment plugs) will interfere with mounted equipment and mounted accessories; NOTE #2: To properly use on rack cabinets, allow sufficient depth BEHIND the rear panel rails for vertically mounting to the cabinet; TAA compliant for GSA Schedule purchases; RoHS Compliant; Manufactured in North America.”,”value”:”Heavy duty cord, either 12 gauge (12/3 SJT) or 14 gauge (14/3 SJT) wire for extreme temperature ranges and integral molded plug; Plug types for 15 Amp models are NEMA 5-15P straight blade or NEMA L5-15P locking type; Plug types for 20 Amp models are NEMA 5-20P straight blade or NEMA L5-20P locking type; Rated 15 or 20 amps, 120 volts; UL/cUL Listed Standard UL1363 file No. E166039 & CSA C22.2 No. 308-14 & CSA C22.2 No. 0.4-04; NOTE #1: Outlet strips can NOT be used between the front & rear panel rails of rack cabinets as they (and the equipment plugs) will interfere with mounted equipment and mounted accessories; NOTE #2: To properly use on rack cabinets, allow sufficient depth BEHIND the rear panel rails for vertically mounting to the cabinet; TAA compliant for GSA Schedule purchases; RoHS Compliant; Manufactured in North America.”},{“name”:”Surge Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Additional Description”,”normalizedValue”:”20A 12 Outlet Vertical Strip w/ switch, 15 ft. shielded cord – 77\” long, Toolless Mount”,”value”:”20A 12 Outlet Vertical Strip w/ switch, 15 ft. shielded cord – 77\” long, Toolless Mount”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Canada”,”value”:”Canada”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.