Power distribution block, Linergy, 3 pole, 2 line, 2 load, 620A Cu, 500A Al, 600V, Square D, Mfr#: 9080LBA365202

$182,99

Linergy power distribution blocks are for terminating wires and are designed to NEMA standards. This three pole block has two lug openings on the line (main) side and two lug openings on the load (branch) side. The line side lug is rated to accept one #4 to 350 kcmil copper or aluminum wire. The load side lugs are rated to accept one #4 to 350 kcmil copper or aluminum wire. The lugs are made of aluminum. The lugs are rated for 620 amperes with copper wire and 500 amperes with aluminum wire. The lugs are rated to 600 volts. The housing is made of general purpose phenolic. These Linergy power distribution blocks are UL component recognized and CSA certified.

9999 in stock

SKU: GRG0801230 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Power Distribution Block 600V 620A”,”rank”:1,”value”:”Power Distribution Block 600V 620A”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”rank”:2,”value”:”3″},{“name”:”Primary Connections/Pole”,”normalizedValue”:”2″,”rank”:4,”value”:”2″},{“name”:”Primary Wire Range (AWG)”,”normalizedValue”:”AWG 6 to 350 kcmil (Copper or Aluminium)”,”rank”:5,”value”:”AWG 6 to 350 kcmil (Copper or Aluminium)”},{“name”:”Secondary Connection/Pole”,”normalizedValue”:”2″,”rank”:6,”value”:”2″},{“name”:”Secondary Wire Range (AWG)”,”normalizedValue”:”AWG 6 to 350 kcmil (Copper or Aluminium)”,”rank”:7,”value”:”AWG 6 to 350 kcmil (Copper or Aluminium)”},{“name”:”Power Distribution Block Design”,”normalizedValue”:”Open”,”rank”:9,”value”:”Open”},{“name”:”Voltage Rating”,”normalizedValue”:”600V AC/DC”,”rank”:10,”value”:”600V AC/DC”},{“name”:”Depth”,”normalizedValue”:”3.13 in”,”value”:”3.13 in”},{“name”:”Standards”,”normalizedValue”:”CE; UL Recognized E60616 CCN XCFR2; CSA File 70361 Class 6228 01″,”value”:”CE; UL Recognized E60616 CCN XCFR2; CSA File 70361 Class 6228 01″},{“name”:”Length”,”normalizedValue”:”5-1/2 in”,”value”:”5.5 in”},{“name”:”Width”,”normalizedValue”:”8.54 in”,”value”:”8.54 in”},{“name”:”Material”,”normalizedValue”:”Phenolic”,”value”:”Phenolic”},{“name”:”Overall Width”,”normalizedValue”:”8.54 in”,”value”:”8.54 in”},{“name”:”Overall Length”,”normalizedValue”:”5-1/2 in”,”value”:”5.5 in”},{“name”:”Line Side Connection Type”,”normalizedValue”:”Lug”,”value”:”Lug”},{“name”:”For Line Copper Wire Size – Minimum”,”normalizedValue”:”6 AWG”,”value”:”6 AWG”},{“name”:”For Line Aluminum Wire Size – Maximum”,”normalizedValue”:”350 kcmil”,”value”:”350 kcmil”},{“name”:”Load Connections/Pole”,”normalizedValue”:”2″,”value”:”2″},{“name”:”For Load Aluminum Wire Size – Maximum”,”normalizedValue”:”350 kcmil”,”value”:”350 kcmil”},{“name”:”Housing Color”,”normalizedValue”:”Black”,”value”:”Black”},{“name”:”Housing Material”,”normalizedValue”:”Phenolic”,”value”:”Phenolic”},{“name”:”For Conductor Material”,”normalizedValue”:”Aluminum, Copper”,”value”:”Aluminum, Copper”},{“name”:”Load Side Connection Type”,”normalizedValue”:”Lug”,”value”:”Lug”},{“name”:”Line Connections/Pole”,”normalizedValue”:”2″,”value”:”2″},{“name”:”For Load Copper Wire Size – Minimum”,”normalizedValue”:”6 AWG”,”value”:”6 AWG”},{“name”:”Maximum Current – Copper Conductor”,”normalizedValue”:”620 A”,”value”:”620 A”},{“name”:”Overall Depth”,”normalizedValue”:”3.13 in”,”value”:”3.13 in”},{“name”:”Terminal Material”,”normalizedValue”:”Aluminum”,”value”:”Aluminum”},{“name”:”Maximum Current – Aluminum Conductor”,”normalizedValue”:”500 A”,”value”:”500 A”},{“name”:”For Line Aluminum Wire Size – Minimum”,”normalizedValue”:”6 AWG”,”value”:”6 AWG”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”302 deg F”,”value”:”302 Degrees F”},{“name”:”Maximum Voltage”,”normalizedValue”:”600 V AC/DC”,”value”:”600 V AC/DC”},{“name”:”For Load Copper Wire Size – Maximum”,”normalizedValue”:”350 kcmil”,”value”:”350 kcmil”},{“name”:”For Line Copper Wire Size – Maximum”,”normalizedValue”:”350 kcmil”,”value”:”350 kcmil”},{“name”:”For Load Aluminum Wire Size – Minimum”,”normalizedValue”:”6 AWG”,”value”:”6 AWG”},{“name”:”Line Side Wire Size Range”,”normalizedValue”:”6 AWG – 350 kcmil”,”value”:”6 AWG – 350 kcmil”},{“name”:”Load Side Wire Range”,”normalizedValue”:”6 AWG – 350 kcmil”,”value”:”6 AWG – 350 kcmil”},{“name”:”Amps”,”normalizedValue”:”500 (Al conductor), 620 (Cu Conductor)”,”value”:”Al conductor: 500 A; Cu Conductor: 620 A”},{“name”:”Mounting”,”normalizedValue”:”Surface Mount”,”value”:”Surface Mount”},{“name”:”Min. Operating Temp.”,”normalizedValue”:”-40°F”,”value”:”-40°F”},{“name”:”Electrical Connection”,”normalizedValue”:”Tin plated Aluminium Lugs”,”value”:”Tin plated Aluminium Lugs”},{“name”:”Wire Strip Length”,”normalizedValue”:”1.06 in (Line), 1.06 in (Load)”,”value”:”Line 1.06 in; Load 1.06 in”},{“name”:”Short Circuit Current Rating”,”normalizedValue”:”100 kA UL 508 A”,”value”:”100 kA UL 508 A”},{“name”:”Weight”,”normalizedValue”:”1.4 kg”,”value”:”1.40 kg”},{“name”:”Max. Operating Temp.”,”normalizedValue”:”302°F”,”value”:”302°F”},{“name”:”Features”,”normalizedValue”:”Mercury Free”,”value”:”Mercury Free”},{“name”:”Height”,”normalizedValue”:”5-1/2 in”,”value”:”5.5 in (139.70 mm)”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-40 to 302°F”,”value”:”-40 to 302°F (-40 to 150°C)”},{“name”:”Certifications”,”normalizedValue”:”CE; CSA file 70361 class 6228 01; UL recognized E60616 CCN XCFR2″,”value”:”CE; CSA file 70361 class 6228 01; UL recognized E60616 CCN XCFR2″},{“name”:”Terminal Tightening Torque”,”normalizedValue”:”Line lug 275 lbf.in (31.07 N.m) AWG 4 to 350 kcmil copper or aluminium; Load lug 275 lbf.in (31.07 N.m) AWG 4 to 350 kcmil copper or aluminium”,”value”:”Line lug 275 lbf.in (31.07 N.m) AWG 4 to 350 kcmil copper or aluminium; Load lug 275 lbf.in (31.07 N.m) AWG 4 to 350 kcmil copper or aluminium”},{“name”:”Wire Size”,”normalizedValue”:”Line 2, AWG 6 to 350 kcmil, copper or aluminium; Load 2, AWG 6 to 350 kcmil, copper or aluminium”,”value”:”Line 2, AWG 6 to 350 kcmil, copper or aluminium; Load 2, AWG 6 to 350 kcmil, copper or aluminium”},{“name”:”Wire Stripping Length”,”normalizedValue”:”Line: 1.06 in (26.92 mm); Load: 1.06 in (26.92 mm)”,”value”:”Line: 1.06 in (26.92 mm); Load: 1.06 in (26.92 mm)”},{“name”:”Current Rating”,”normalizedValue”:”620 A copper; 500 A aluminium”,”value”:”620 A copper; 500 A aluminium”},{“name”:”Block Material”,”normalizedValue”:”Phenolic: block”,”value”:”Phenolic: block”},{“name”:”End Barrier”,”normalizedValue”:”9080LB53″,”value”:”9080LB53″},{“name”:”Terminals Per Pole”,”normalizedValue”:”2 line; 2 load”,”value”:”2 line; 2 load”},{“name”:”Number of Cables”,”normalizedValue”:”line 2 , AWG 6…350 kcmil, copper or aluminium, load 2 , AWG 6…350 kcmil, copper or aluminium”,”value”:”line 2 , AWG 6…350 kcmil, copper or aluminium, load 2 , AWG 6…350 kcmil, copper or aluminium”},{“name”:”Line Rated Current”,”normalizedValue”:”620-620 A copper, 500-500 A aluminium”,”value”:”620-620 A copper, 500-500 A aluminium”},{“name”:”Product or Component Type”,”normalizedValue”:”Power Distribution Block”,”value”:”Power Distribution Block”},{“name”:”Range of Product”,”normalizedValue”:”9080LB”,”value”:”9080LB”},{“name”:”Number of Terminals”,”normalizedValue”:”2 line, 2 load”,”value”:”2 line, 2 load”},{“name”:”Connections – Terminals”,”normalizedValue”:”line lug 275 lbf.in AWG 4…350 kcmil copper or aluminium, load lug 275 lbf.in AWG 4…350 kcmil copper or aluminium”,”value”:”line lug 275 lbf.in AWG 4…350 kcmil copper or aluminium, load lug 275 lbf.in AWG 4…350 kcmil copper or aluminium”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Power distribution block, Linergy, 3 pole, 2 line, 2 load, 620A Cu, 500A Al, 600V, Square D, Mfr#: 9080LBA365202”