Description
[{“name”:”Standards”,”normalizedValue”:”EN/IEC 60255-1″,”value”:”EN/IEC 60255-1″},{“name”:”Item”,”normalizedValue”:”Phase Ctrl Relay,380-480VAC In 8A,Dpdt”,”value”:”Phase Ctrl Relay,380-480VAC In 8A,Dpdt”},{“name”:”Response Time”,”normalizedValue”:”<= 300 ms","value":"<= 300 ms"},{"name":"Width","normalizedValue":"22.5 mm","value":"22.5 mm"},{"name":"Setting Accuracy Of The Switching Threshold","normalizedValue":"+/- 10 % of the full scale","value":"+/- 10 % of the full scale"},{"name":"Reset Time","normalizedValue":"1500 ms at maximum voltage","value":"1500 ms at maximum voltage"},{"name":"Immunity To Microbreaks","normalizedValue":"10 msec","value":"10 ms"},{"name":"Shock Resistance","normalizedValue":"15 gn 11 ms) not in operation IEC 60068-2-27 || 5 gn 11 ms) in operation IEC 60068-2-27","value":"15 gn 11 ms) not in operation IEC 60068-2-27 || 5 gn 11 ms) in operation IEC 60068-2-27"},{"name":"Measurement Error","normalizedValue":"< 1 % over the whole range with voltage variation || < 0.05 %/°C with temperature variation","value":"< 1 % over the whole range with voltage variation || < 0.05 %/°C with temperature variation"},{"name":"Hysteresis","normalizedValue":"2-2 % fixed selectable","value":"2-2 % fixed selectable"},{"name":"Connections - Terminals","normalizedValue":"screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end || screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end","value":"screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end || screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end"},{"name":"Measurement Range","normalizedValue":"380...480 V voltage AC","value":"380...480 V voltage AC"},{"name":"[Us] Rated Supply Voltage","normalizedValue":"380...480 V AC","value":"380...480 V AC"},{"name":"Ambient Air Temperature For Storage","normalizedValue":"-40-70°C","value":"-40-70°C"},{"name":"Threshold Adjustment Voltage","normalizedValue":"2...20 % of Un selected","value":"2...20 % of Un selected"},{"name":"Minimum Switching Current","normalizedValue":"10 mA 5 V DC","value":"10 mA 5 V DC"},{"name":"Ambient Air Temperature For Operation","normalizedValue":"-20-50°C 60 Hz || -20-60°C 50 Hz AC/DC","value":"-20-50°C 60 Hz || -20-60°C 50 Hz AC/DC"},{"name":"Supply Voltage Limits","normalizedValue":"304-576 V AC","value":"304-576 V AC"},{"name":"Voltage Detection Threshold","normalizedValue":"< 100 V AC","value":"< 100 V AC"},{"name":"Electromagnetic Compatibility","normalizedValue":"immunity for residential, commercial and light-industrial environments EN/IEC 61000-6-1 || immunity for industrial environments EN/IEC 61000-6-2 || emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 || emission standard for industrial environments EN/IEC 61000-6-4 || electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 || electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test 10 V/mlevel 3 IEC 61000-4-3 || electrical fast transient/burst immunity test 4 kV direct)level 4 IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV capacitive coupling)level 4 IEC 61000-4-4 || surge immunity test 4 kV common mode)level 4 IEC 61000-4-5 || surge immunity test 2 kV differential mode)level 4 IEC 61000-4-5 || conducted and radiated emissionsclass B group 1 CISPR 11 || conducted and radiated emissionsclass B CISPR 22","value":"immunity for residential, commercial and light-industrial environments EN/IEC 61000-6-1 || immunity for industrial environments EN/IEC 61000-6-2 || emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 || emission standard for industrial environments EN/IEC 61000-6-4 || electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 || electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test 10 V/mlevel 3 IEC 61000-4-3 || electrical fast transient/burst immunity test 4 kV direct)level 4 IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV capacitive coupling)level 4 IEC 61000-4-4 || surge immunity test 4 kV common mode)level 4 IEC 61000-4-5 || surge immunity test 2 kV differential mode)level 4 IEC 61000-4-5 || conducted and radiated emissionsclass B group 1 CISPR 11 || conducted and radiated emissionsclass B CISPR 22"},{"name":"Voltage Range","normalizedValue":"380...480 V phase to phase","value":"380...480 V phase to phase"},{"name":"Power Consumption In Va","normalizedValue":"15-15 VA 480 V AC 60 Hz","value":"15-15 VA 480 V AC 60 Hz"},{"name":"Supply Frequency","normalizedValue":"50...60 Hz +/- 10 %","value":"50...60 Hz +/- 10 %"},{"name":"Product Certifications","normalizedValue":"CSA || RCM, UL || GL || CE || CCC || EAC","value":"CSA || RCM || UL || GL || CE || CCC || EAC"},{"name":"Output Contacts","normalizedValue":"2 C/O","value":"2 C/O"},{"name":"Vibration Resistance","normalizedValue":"0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6 || 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6 || 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6 || 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6","value":"0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6 || 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6 || 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6 || 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6"},{"name":"Contacts Type And Composition","normalizedValue":"O, 2 C","value":"2 C/O"},{"name":"Ip Degree Of Protection","normalizedValue":"IP20 IEC 60529 terminals) || IP40 IEC 60529 housing) || IP50 IEC 60529 front panel)","value":"IP20 IEC 60529 terminals) || IP40 IEC 60529 housing) || IP50 IEC 60529 front panel)"},{"name":"Run-Up Delay At Power-Up","normalizedValue":"650 msec","value":"650 ms"},{"name":"Relative Humidity","normalizedValue":"93-97 % 25-55°C IEC 60068-2-30","value":"93-97 % 25-55°C IEC 60068-2-30"},{"name":"Setting Accuracy Of Time Delay","normalizedValue":"0.9167","value":"0.916666666666667"},{"name":"Relay Type","normalizedValue":"control relay","value":"control relay"},{"name":"Pollution Degree","normalizedValue":"3 IEC 60664-1 || 3 UL 508","value":"3 IEC 60664-1 || 3 UL 508"},{"name":"Mounting Support","normalizedValue":"35 mm DIN rail conforming to EN/IEC 60715","value":"35 mm DIN rail conforming to EN/IEC 60715"},{"name":"Dielectric Test Voltage","normalizedValue":"2.5 kV AC 50 Hz, 1 min IEC 60255-27","value":"2.5 kV AC 50 Hz, 1 min IEC 60255-27"},{"name":"Utilisation Category","normalizedValue":"AC-15 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || AC-1 IEC 60947-4-1 || DC-1 IEC 60947-4-1","value":"AC-15 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || AC-1 IEC 60947-4-1 || DC-1 IEC 60947-4-1"},{"name":"Insulation Resistance","normalizedValue":"> 100 MOhm 500 V DC IEC 60255-27″,”value”:”> 100 MOhm 500 V DC IEC 60255-27″},{“name”:”Phase”,”normalizedValue”:”3 phase”,”value”:”3 phase”},{“name”:”Switching Capacity In Va”,”normalizedValue”:”2,000 VA”,”value”:”2000 VA”},{“name”:”Status Led”,”normalizedValue”:”LED (Yellow) relay ON || LED (Green) power ON”,”value”:”LED (Yellow) relay ON || LED (Green) power ON”},{“name”:”Time Delay Drift”,”normalizedValue”:”<= 0.05 % per degree centigrade depending permissible ambient air temperature || <= 1 % within the supply voltage range","value":"<= 0.05 % per degree centigrade depending permissible ambient air temperature || <= 1 % within the supply voltage range"},{"name":"Relay Name","normalizedValue":"RM22TR","value":"RM22TR"},{"name":"Control Circuit Voltage Limits","normalizedValue":"20 % + 20 % Un","value":"20 % + 20 % Un"},{"name":"Tightening Torque","normalizedValue":"0.6-1 N.m IEC 60947-1","value":"0.6-1 N.m IEC 60947-1"},{"name":"Mechanical Durability","normalizedValue":"10000000 cycles","value":"10000000 cycles"},{"name":"Overvoltage Category","normalizedValue":"III IEC 60664-1 || III UL 508","value":"III IEC 60664-1 || III UL 508"},{"name":"Repeat Accuracy","normalizedValue":"+/- 0.5 % input and measurement circuit","value":"+/- 0.5 % input and measurement circuit"},{"name":"Switching Threshold Drift","normalizedValue":"<= 0.05 % per degree centigrade depending permissible ambient air temperature || <= 1 % within the supply voltage range","value":"<= 0.05 % per degree centigrade depending permissible ambient air temperature || <= 1 % within the supply voltage range"},{"name":"Housing Material","normalizedValue":"self-extinguishing plastic","value":"self-extinguishing plastic"},{"name":"Product Or Component Type","normalizedValue":"control relay","value":"3-phase control relay"},{"name":"Maximum Measuring Cycle","normalizedValue":"150 msec","value":"150 ms measurement cycle as true rms value"},{"name":"Electrical Durability","normalizedValue":"100000 cycles","value":"100000 cycles"},{"name":"Maximum Switching Current","normalizedValue":"8 A","value":"8 A AC"},{"name":"Maximum Switching Voltage","normalizedValue":"250 V AC","value":"250 V AC"},{"name":"Relay Monitored Parameters","normalizedValue":"undervoltage detection || phase sequence || phase failure detection","value":"undervoltage detection || phase sequence || phase failure detection"},{"name":"Time Delay Type","normalizedValue":"without","value":"without"},{"name":"Contacts Material","normalizedValue":"cadmium free","value":"cadmium free"},{"name":"Mounting Position","normalizedValue":"any position","value":"any position"},{"name":"Country of Origin (subject to change)","normalizedValue":"Indonesia","value":"Indonesia"},{"name":"Package Quantity","normalizedValue":"1","value":"1"}]

Reviews
There are no reviews yet.