Description
[{“name”:”Item – Relay”,”normalizedValue”:”Current Sensing Relay”,”rank”:1,”value”:”Current Sensing Relay”},{“name”:”AC Contact Rating – Relay”,”normalizedValue”:”8 A @ 250 V”,”rank”:3,”value”:”8 A @ 250 V”},{“name”:”DC Contact Rating – Relay”,”normalizedValue”:”0.01 A @ 5 V”,”rank”:4,”value”:”0.01 A @ 5V”},{“name”:”Contact Form – Relay”,”normalizedValue”:”DPDT”,”rank”:6,”value”:”DPDT”},{“name”:”Mounting – Relay”,”normalizedValue”:”Surface”,”rank”:7,”value”:”Surface”},{“name”:”Response Time”,”normalizedValue”:”\u003c= 300 ms”,”value”:”\u003c= 300 ms”},{“name”:”Contact Form”,”normalizedValue”:”DPDT”,”value”:”DPDT”},{“name”:”Item”,”normalizedValue”:”Phase Control Relay”,”value”:”Phase Control Relay”},{“name”:”Body Height – Relay”,”normalizedValue”:”3.54 in”,”value”:”3.54 in”},{“name”:”Body Width – Relay”,”normalizedValue”:”0.9 in”,”value”:”0.9 in”},{“name”:”Body Depth – Relay”,”normalizedValue”:”3.15 in”,”value”:”3.15 in”},{“name”:”Standards”,”normalizedValue”:”C-Tick, CSA Certified, EN/IEC 60255-1, EN/IEC 61000-6-4, EU RoHS, GL, GOST, Reach Regulation, UL Listed”,”value”:”C-Tick, CSA Certified, EN/IEC 60255-1, EN/IEC 61000-6-4, EU RoHS, GL, GOST, Reach Regulation, UL Listed”},{“name”:”Electrical Connection”,”normalizedValue”:”Terminal Strip”,”value”:”Terminal Strip”},{“name”:”Input or Control Voltage”,”normalizedValue”:”200 to 240 V AC”,”value”:”200 to 240 V AC”},{“name”:”Sensing Amp Range”,”normalizedValue”:”0.01 to 8 A”,”value”:”0.01 to 8.00 A”},{“name”:”Trip Point”,”normalizedValue”:”0.01 to 8 A (Adjustable)”,”value”:”Adjustable 0.01 to 8.00 A”},{“name”:”Core Type – Relay”,”normalizedValue”:”Solid”,”value”:”Solid”},{“name”:”Type of Output”,”normalizedValue”:”Relay”,”value”:”Relay”},{“name”:”Trip Delay”,”normalizedValue”:”0.1 to 30 sec”,”value”:”0.10 to 30 sec”},{“name”:”Minimum Switching Current”,”normalizedValue”:”10 mA”,”value”:”10 mA”},{“name”:”Flat Pin Width”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”122 deg F”,”value”:”122 Degrees F”},{“name”:”Input Voltage”,”normalizedValue”:”380 to 480V AC”,”value”:”380 to 480V AC”},{“name”:”Contact Rating (AC)”,”normalizedValue”:”8 A @ 250V”,”value”:”8 A @ 250V”},{“name”:”Current Rating”,”normalizedValue”:”8 A”,”value”:”8 A”},{“name”:”Mechanical Operating Durability”,”normalizedValue”:”30,000,000″,”value”:”30,000,000″},{“name”:”Electrical Operating Durability”,”normalizedValue”:”100,000″,”value”:”100,000″},{“name”:”Weight”,”normalizedValue”:”3.2 oz”,”value”:”3.2 oz”},{“name”:”Mounting Style”,”normalizedValue”:”DIN Rail”,”value”:”DIN Rail”},{“name”:”Body Width”,”normalizedValue”:”0.89 in”,”value”:”0.89 in”},{“name”:”Body Depth”,”normalizedValue”:”3.13 in”,”value”:”3.13 in”},{“name”:”Monitored Parameters”,”normalizedValue”:”Overvoltage, Phase Failure, Phase Sequence”,”value”:”Overvoltage, Phase Failure, Phase Sequence”},{“name”:”Body Height”,”normalizedValue”:”3.54 in”,”value”:”3.54 in”},{“name”:”Contact Rating (DC)”,”normalizedValue”:”0.01 A @ 5V”,”value”:”0.01 A @ 5V”},{“name”:”Maximum Switching Current”,”normalizedValue”:”8 A”,”value”:”8 A”},{“name”:”Restart”,”normalizedValue”:”Auto”,”value”:”Auto”},{“name”:”Housing Material”,”normalizedValue”:”plastic”,”value”:”Plastic”},{“name”:”IP Rating”,”normalizedValue”:”IP40″,”value”:”IP40″},{“name”:”Overall Depth”,”normalizedValue”:”3.13 in”,”value”:”3.13 in”},{“name”:”Maximum Switching Voltage”,”normalizedValue”:”250 V AC”,”value”:”250V AC”},{“name”:”Restart Time Delay”,”normalizedValue”:”1.5 sec”,”value”:”1.5 sec”},{“name”:”Maximum Switching Capacity”,”normalizedValue”:”1,250 VA”,”value”:”1,250 VA”},{“name”:”Power Consumption”,”normalizedValue”:”1,250 VA”,”value”:”1,250 VA”},{“name”:”Number of Pins”,”normalizedValue”:”9″,”value”:”9″},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-4 deg F”,”value”:”-4 Degrees F”},{“name”:”Setting Accuracy Of Time Delay”,”normalizedValue”:”0.9167″,”value”:”0.916666666666667″},{“name”:”Setting Accuracy Of The Switching Threshold”,”normalizedValue”:”+/- 10 % of the full scale”,”value”:”+/- 10 % of the full scale”},{“name”:”Threshold Adjustment Voltage”,”normalizedValue”:”2…20 % of Un selected”,”value”:”2…20 % of Un selected”},{“name”:”Overvoltage Category”,”normalizedValue”:”III IEC 60664-1 || III UL 508″,”value”:”III IEC 60664-1 || III UL 508″},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP20 IEC 60529 terminals) || IP40 IEC 60529 housing) || IP50 IEC 60529 front panel)”,”value”:”IP20 IEC 60529 terminals) || IP40 IEC 60529 housing) || IP50 IEC 60529 front panel)”},{“name”:”Width”,”normalizedValue”:”22.5 mm”,”value”:”22.5 mm”},{“name”:”Run-Up Delay At Power-Up”,”normalizedValue”:”650 msec”,”value”:”650 ms”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-20-50°C 60 Hz || -20-60°C 50 Hz AC/DC”,”value”:”-20-50°C 60 Hz || -20-60°C 50 Hz AC/DC”},{“name”:”Repeat Accuracy”,”normalizedValue”:”+/- 0.5 % input and measurement circuit || +/- 3 % time delay”,”value”:”+/- 0.5 % input and measurement circuit || +/- 3 % time delay”},{“name”:”Nominal Output Current”,”normalizedValue”:”8 A”,”value”:”8A”},{“name”:”Measurement Error”,”normalizedValue”:”\u003c 1 % over the whole range with voltage variation || \u003c 0.05 %/°C with temperature variation”,”value”:”\u003c 1 % over the whole range with voltage variation || \u003c 0.05 %/°C with temperature variation”},{“name”:”Time Delay Type”,”normalizedValue”:”adjustable 0.1…30 s, +/- 10 % of the full scale value on crossing the threshold Tt”,”value”:”adjustable 0.1…30 s, +/- 10 % of the full scale value on crossing the threshold Tt”},{“name”:”Relay Name”,”normalizedValue”:”RM22TR”,”value”:”RM22TR”},{“name”:”Electrical Durability”,”normalizedValue”:”100000 cycles”,”value”:”100000 cycles”},{“name”:”Hysteresis”,”normalizedValue”:”2-2 % fixed selectable”,”value”:”2-2 % fixed selectable”},{“name”:”Maximum Measuring Cycle”,”normalizedValue”:”150 msec”,”value”:”150 ms measurement cycle as true rms value”},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”20 % + 20 % Un”,”value”:”20 % + 20 % Un”},{“name”:”Relay Monitored Parameters”,”normalizedValue”:”overvoltage and undervoltage detection || phase sequence || phase failure detection”,”value”:”overvoltage and undervoltage detection || phase sequence || phase failure detection”},{“name”:”Tightening Torque”,”normalizedValue”:”0.6-1 N.m IEC 60947-1″,”value”:”0.6-1 N.m IEC 60947-1″},{“name”:”Connections – Terminals”,”normalizedValue”:”screw terminals, 2 x 0.5…2 x 2.5 mm² AWG 20…AWG 14) solid without cable end || screw terminals, 2 x 0.2…2 x 1.5 mm² AWG 24…AWG 16) flexible with cable end || screw terminals, 1 x 0.5…1 x 3.3 mm² AWG 20…AWG 12) solid without cable end || screw terminals, 1 x 0.2…1 x 2.5 mm² AWG 24…AWG 14) flexible with cable end”,”value”:”screw terminals, 2 x 0.5…2 x 2.5 mm² AWG 20…AWG 14) solid without cable end || screw terminals, 2 x 0.2…2 x 1.5 mm² AWG 24…AWG 16) flexible with cable end || screw terminals, 1 x 0.5…1 x 3.3 mm² AWG 20…AWG 12) solid without cable end || screw terminals, 1 x 0.2…1 x 2.5 mm² AWG 24…AWG 14) flexible with cable end”},{“name”:”Voltage Range”,”normalizedValue”:”380…480 V phase to phase”,”value”:”380…480 V phase to phase”},{“name”:”Supply Frequency”,”normalizedValue”:”50…60 Hz +/- 10 %”,”value”:”50…60 Hz +/- 10 %”},{“name”:”Time Delay Drift”,”normalizedValue”:”\u003c= 0.05 % per degree centigrade depending permissible ambient air temperature || \u003c= 1 % within the supply voltage range”,”value”:”\u003c= 0.05 % per degree centigrade depending permissible ambient air temperature || \u003c= 1 % within the supply voltage range”},{“name”:”Contacts Material”,”normalizedValue”:”cadmium free”,”value”:”cadmium free”},{“name”:”Immunity To Microbreaks”,”normalizedValue”:”10 msec”,”value”:”10 ms”},{“name”:”[Us] Rated Supply Voltage”,”normalizedValue”:”380…480 V AC”,”value”:”380…480 V AC”},{“name”:”Relative Humidity”,”normalizedValue”:”93-97 % 25-55°C IEC 60068-2-30″,”value”:”93-97 % 25-55°C IEC 60068-2-30″},{“name”:”Pollution Degree”,”normalizedValue”:”3 IEC 60664-1 || 3 UL 508″,”value”:”3 IEC 60664-1 || 3 UL 508″},{“name”:”Utilisation Category”,”normalizedValue”:”AC-15 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || AC-1 IEC 60947-4-1 || DC-1 IEC 60947-4-1″,”value”:”AC-15 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || AC-1 IEC 60947-4-1 || DC-1 IEC 60947-4-1″},{“name”:”Output Contacts”,”normalizedValue”:”2 C/O”,”value”:”2 C/O”},{“name”:”Switching Capacity In Va”,”normalizedValue”:”2,000 VA”,”value”:”2000 VA”},{“name”:”Vibration Resistance”,”normalizedValue”:”0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6 || 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6 || 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6 || 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6″,”value”:”0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6 || 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6 || 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6 || 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6″},{“name”:”Voltage Detection Threshold”,”normalizedValue”:”\u003c 100 V AC”,”value”:”\u003c 100 V AC”},{“name”:”Relay Type”,”normalizedValue”:”control relay”,”value”:”control relay”},{“name”:”Product Or Component Type”,”normalizedValue”:”control relay”,”value”:”3-phase control relay”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-70°C”,”value”:”-40-70°C”},{“name”:”Status Led”,”normalizedValue”:”LED (Yellow) relay ON || LED (Green) power ON”,”value”:”LED (Yellow) relay ON || LED (Green) power ON”},{“name”:”Switching Threshold Drift”,”normalizedValue”:”\u003c= 0.05 % per degree centigrade depending permissible ambient air temperature || \u003c= 1 % within the supply voltage range”,”value”:”\u003c= 0.05 % per degree centigrade depending permissible ambient air temperature || \u003c= 1 % within the supply voltage range”},{“name”:”Mounting Position”,”normalizedValue”:”any position”,”value”:”any position”},{“name”:”Power Consumption In Va”,”normalizedValue”:”15-15 VA 480 V AC 60 Hz”,”value”:”15-15 VA 480 V AC 60 Hz”},{“name”:”Mechanical Durability”,”normalizedValue”:”10000000 cycles”,”value”:”10000000 cycles”},{“name”:”Mounting Support”,”normalizedValue”:”35 mm DIN rail conforming to EN/IEC 60715″,”value”:”35 mm DIN rail conforming to EN/IEC 60715″},{“name”:”Reset Time”,”normalizedValue”:”1500 ms at maximum voltage”,”value”:”1500 ms at maximum voltage”},{“name”:”Product Certifications”,”normalizedValue”:”UL, GL || CSA || RCM || CE || EAC || CCC”,”value”:”GL || CSA || RCM || CE || EAC || CCC || UL”},{“name”:”Contacts Type And Composition”,”normalizedValue”:”O, 2 C”,”value”:”2 C/O”},{“name”:”Shock Resistance”,”normalizedValue”:”15 gn 11 ms) not in operation IEC 60068-2-27 || 5 gn 11 ms) in operation IEC 60068-2-27″,”value”:”15 gn 11 ms) not in operation IEC 60068-2-27 || 5 gn 11 ms) in operation IEC 60068-2-27″},{“name”:”Measurement Range”,”normalizedValue”:”380…480 V voltage AC”,”value”:”380…480 V voltage AC”},{“name”:”Insulation Resistance”,”normalizedValue”:”\u003e 100 MOhm 500 V DC IEC 60255-27″,”value”:”\u003e 100 MOhm 500 V DC IEC 60255-27″},{“name”:”Phase”,”normalizedValue”:”3 phase”,”value”:”3 phase”},{“name”:”Dielectric Test Voltage”,”normalizedValue”:”2.5 kV AC 50 Hz, 1 min IEC 60255-27″,”value”:”2.5 kV AC 50 Hz, 1 min IEC 60255-27″},{“name”:”Supply Voltage Limits”,”normalizedValue”:”304-576 V AC”,”value”:”304-576 V AC”},{“name”:”Electromagnetic Compatibility”,”normalizedValue”:”immunity for residential, commercial and light-industrial environments EN/IEC 61000-6-1 || immunity for industrial environments EN/IEC 61000-6-2 || emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 || emission standard for industrial environments EN/IEC 61000-6-4 || electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 || electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test 10 V/mlevel 3 IEC 61000-4-3 || electrical fast transient/burst immunity test 4 kV direct)level 4 IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV capacitive coupling)level 4 IEC 61000-4-4 || surge immunity test 4 kV common mode)level 4 IEC 61000-4-5 || surge immunity test 2 kV differential mode)level 4 IEC 61000-4-5 || conducted and radiated emissionsclass B group 1 CISPR 11 || conducted and radiated emissionsclass B CISPR 22″,”value”:”immunity for residential, commercial and light-industrial environments EN/IEC 61000-6-1 || immunity for industrial environments EN/IEC 61000-6-2 || emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 || emission standard for industrial environments EN/IEC 61000-6-4 || electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 || electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test 10 V/mlevel 3 IEC 61000-4-3 || electrical fast transient/burst immunity test 4 kV direct)level 4 IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV capacitive coupling)level 4 IEC 61000-4-4 || surge immunity test 4 kV common mode)level 4 IEC 61000-4-5 || surge immunity test 2 kV differential mode)level 4 IEC 61000-4-5 || conducted and radiated emissionsclass B group 1 CISPR 11 || conducted and radiated emissionsclass B CISPR 22″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Indonesia”,”value”:”Indonesia”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.