Panel-Tran Zone Power Center, 7.5 kVA, NEMA 3R, 115°C, 120/240V AC, 480V AC

$2593,99

Temporary Power Station, Single Phase, Input Voltage 480V AC, Output Voltage 120/240V AC, 7.5 kVA Rating, Output Connection (8) Single Pole or (4) Two Pole Circuit Breakers, Mounting Wall, 60 Hz Hz, 30 A Amps, Input Connection Hard Wired, Input Protection 25A Circuit Breaker, Secondary Protection 40A Circuit Breaker, Enclosure Material Steel, Color Gray, NEMA Rating 3R, Overall Height 32.13 in, Overall Width 15.88 in, Overall Depth 11 in, Standards CSA C22.2 No. 47, NEC 450-3, UL 1062

9999 in stock

SKU: GRG0688371 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Panel-Tran Zone Power Center”,”rank”:2,”value”:”Panel-Tran Zone Power Center”},{“name”:”Input Voltage – Transformer”,”normalizedValue”:”480V AC”,”rank”:3,”value”:”480V AC”},{“name”:”Mounting – Transformer”,”normalizedValue”:”Wall”,”rank”:7,”value”:”Wall”},{“name”:”Hz – Electrical”,”normalizedValue”:”60″,”rank”:8,”value”:”60 Hz”},{“name”:”IP Rating”,”normalizedValue”:”IP14″,”rank”:10,”value”:”IP14″},{“name”:”Color”,”normalizedValue”:”Gray”,”rank”:13,”value”:”Gray”},{“name”:”Standards”,”normalizedValue”:”CSA C22.2 No. 47, NEC 450-3, UL 1062″,”value”:”CSA C22.2 No. 47, NEC 450-3, UL 1062″},{“name”:”Input Connection”,”normalizedValue”:”Hard Wired”,”value”:”Hard Wired”},{“name”:”Output Connection”,”normalizedValue”:”Single Pole or Two Pole Circuit Breakers”,”value”:”(8) Single Pole or (4) Two Pole Circuit Breakers”},{“name”:”Enclosure Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Amps”,”normalizedValue”:”30″,”value”:”30 A”},{“name”:”Input Protection”,”normalizedValue”:”25 A (Circuit Breaker)”,”value”:”25A Circuit Breaker”},{“name”:”Secondary Protection”,”normalizedValue”:”40 A (Circuit Breaker)”,”value”:”40A Circuit Breaker”},{“name”:”Depth”,”normalizedValue”:”11 in”,”value”:”11 in”},{“name”:”VA Rating – Transformer”,”normalizedValue”:”7.5 kVA”,”value”:”7.5 kVA”},{“name”:”Output Voltage – Transformer”,”normalizedValue”:”120/240V AC”,”value”:”120/240V AC”},{“name”:”Includes”,”normalizedValue”:”(8) Single Pole or (4) Two Pole Circuit Breaker Slots”,”value”:”(8) Single Pole or (4) Two Pole Circuit Breaker Slots”},{“name”:”Winding Material – Transformer”,”normalizedValue”:”Aluminum”,”value”:”Aluminum”},{“name”:”Height”,”normalizedValue”:”32.13 in”,”value”:”32.13 in”},{“name”:”Temp. Rise”,”normalizedValue”:”115 deg C”,”value”:”115°C”},{“name”:”Enclosure Rating”,”normalizedValue”:”NEMA 3R”,”value”:”NEMA 3R”},{“name”:”Width”,”normalizedValue”:”15.88 in”,”value”:”15.88 in”},{“name”:”Phase – Electrical”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Enclosure Type”,”normalizedValue”:”Encapsulated”,”value”:”Encapsulated”},{“name”:”Number of Outlets”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Insulation Max. Temp.”,”normalizedValue”:”180 °C”,”value”:”180 °C”},{“name”:”Primary Breaker”,”normalizedValue”:”ED42B025L (25A)”,”value”:”ED42B025L (25A)”},{“name”:”Electrostatic Shield”,”normalizedValue”:”Shielded”,”value”:”Shielded”},{“name”:”Product Category”,”normalizedValue”:”Panel-Tran Zone Power Centers”,”value”:”Panel-Tran Zone Power Centers”},{“name”:”CSA Standard”,”normalizedValue”:”C22.2 No 47″,”value”:”C22.2 No 47″},{“name”:”UL Insulation Class”,”normalizedValue”:”180°C”,”value”:”180°C”},{“name”:”Carton Quantity”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Primary Voltage”,”normalizedValue”:”480″,”value”:”480″},{“name”:”Taps % Steps”,”normalizedValue”:”0.05″,”value”:”0.05″},{“name”:”BNFC Taps”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Construction”,”normalizedValue”:”Encapsulated”,”value”:”Encapsulated”},{“name”:”UL Standard”,”normalizedValue”:”UL 1062″,”value”:”UL 1062″},{“name”:”Max Temperature Rise”,”normalizedValue”:”115 Degrees Celsius”,”value”:”115 Degrees Celsius”},{“name”:”Secondary Breaker”,”normalizedValue”:”Q240 (40A)”,”value”:”Q240 (40A)”},{“name”:”Inlet Voltage Rating”,”normalizedValue”:”480V AC”,”value”:”480V AC”},{“name”:”Power Station Style”,”normalizedValue”:”Wall Mount”,”value”:”Wall Mount”},{“name”:”Transformer Size”,”normalizedValue”:”7.5 kVA”,”value”:”7.5 kVA”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Number of Wheels”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Outlet Circuit Protection Rating”,”normalizedValue”:”40 A”,”value”:”40 A”},{“name”:”Inlet Circuit Protection Rating”,”normalizedValue”:”25 A”,”value”:”25 A”},{“name”:”Housing Color”,”normalizedValue”:”Gray”,”value”:”Gray”},{“name”:”Outlet Voltage Rating”,”normalizedValue”:”120/240V AC”,”value”:”120/240V AC”},{“name”:”Outlets Included”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Inlet Connection”,”normalizedValue”:”Hard Wired”,”value”:”Hard Wired”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Panel-Tran Zone Power Center, 7.5 kVA, NEMA 3R, 115°C, 120/240V AC, 480V AC”