Description
[{“name”:”Item”,”normalizedValue”:”PANEL MOUNTED TIMER MONOFUNCTION 3 MIN T”,”rank”:1,”value”:”PANEL MOUNTED TIMER MONOFUNCTION 3 MIN T”},{“name”:”Height”,”normalizedValue”:”62 mm”,”value”:”62 mm”},{“name”:”Standards”,”normalizedValue”:”UL 508, IEC 61812-1″,”value”:”UL 508, IEC 61812-1″},{“name”:”Setting Accuracy of Time Delay”,”normalizedValue”:”+/- 10 % of full scale 25°C IEC 61812-1″,”value”:”+/- 10 % of full scale 25°C IEC 61812-1″},{“name”:”Product or Component Type”,”normalizedValue”:”timer”,”value”:”timer”},{“name”:”Disturbance Radiated/Conducted”,”normalizedValue”:”class B EN 50022″,”value”:”class B EN 50022″},{“name”:”Time Delay Type”,”normalizedValue”:”A”,”value”:”A”},{“name”:”Pollution Degree”,”normalizedValue”:”3 IEC 60664-1″,”value”:”3 IEC 60664-1″},{“name”:”[Us] Rated Supply Voltage”,”normalizedValue”:”110…230 V AC/DC”,”value”:”110…230 V AC/DC”},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”4 kV IEC 60947-1, 4 kV IEC 60664-1″,”value”:”4 kV IEC 60947-1, 4 kV IEC 60664-1″},{“name”:”Shock Resistance”,”normalizedValue”:”+/- 15 gn 11 ms 6 shocks on each axis)IEC 60068-2-27″,”value”:”+/- 15 gn 11 ms 6 shocks on each axis)IEC 60068-2-27″},{“name”:”Range of Product”,”normalizedValue”:”Harmony XB5″,”value”:”Harmony XB5″},{“name”:”Electromagnetic Compatibility”,”normalizedValue”:”electrostatic discharge 6 kV level 3 conforming to IEC 61000-4-2, electromagnetic emission class B conforming to IEC 55011″,”value”:”electrostatic discharge 6 kV level 3 conforming to IEC 61000-4-2, electromagnetic emission class B conforming to IEC 55011″},{“name”:”Temporary Permissible Current”,”normalizedValue”:”10 A 0.01 s”,”value”:”10 A 0.01 s”},{“name”:”Reset Time”,”normalizedValue”:”30 ms after time delay on de-energisation, 60 ms during time delay on de-energisation”,”value”:”30 ms after time delay on de-energisation, 60 ms during time delay on de-energisation”},{“name”:”Maximum Voltage Drop”,”normalizedValue”:”5 V”,”value”:”5 V”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-20-60°C”,”value”:”-20-60°C”},{“name”:”Minimum Switching Current”,”normalizedValue”:”10 mA”,”value”:”10 mA”},{“name”:”Protection Type”,”normalizedValue”:”overvoltage protection”,”value”:”overvoltage protection”},{“name”:”Bezel Material”,”normalizedValue”:”Plastic”,”value”:”plastic”},{“name”:”Time Delay Range”,”normalizedValue”:”3…60 min”,”value”:”3…60 min”},{“name”:”Device Presentation”,”normalizedValue”:”monolithic product”,”value”:”monolithic product”},{“name”:”Thickness”,”normalizedValue”:”1-6 mm”,”value”:”1-6 mm”},{“name”:”Voltage Drift”,”normalizedValue”:”+/- 0.2 %/V”,”value”:”+/- 0.2 %/V”},{“name”:”Fixing Collar Material”,”normalizedValue”:”plastic”,”value”:”plastic”},{“name”:”Supply Voltage Limits”,”normalizedValue”:”93.5-253 V AC/DC”,”value”:”93.5-253 V AC/DC”},{“name”:”Mounting Diameter”,”normalizedValue”:”22 mm”,”value”:”22 mm”},{“name”:”Dielectric Strength”,”normalizedValue”:”1500 V IEC 61812-1″,”value”:”1500 V IEC 61812-1″},{“name”:”Surge Withstand”,”normalizedValue”:”2 kV, level 3 IEC 61000-4-5″,”value”:”2 kV, level 3 IEC 61000-4-5″},{“name”:”Temperature Drift”,”normalizedValue”:”+/- 0.05 %/°C”,”value”:”+/- 0.05 %/°C”},{“name”:”Tightening Torque”,”normalizedValue”:”0.5 N.m”,”value”:”0.5 N.m”},{“name”:”Ip Degree of Protection”,”normalizedValue”:”IP65 front: conforming to IEC 60529, IP20 back: conforming to IEC 60529″,”value”:”IP65 front: conforming to IEC 60529, IP20 back: conforming to IEC 60529″},{“name”:”Connections – Terminals”,”normalizedValue”:”screw terminals 1 x 4 mm² IEC 60947-1, screw terminals 1 x 2.5 mm² IEC 60947-1″,”value”:”screw terminals 1 x 4 mm² IEC 60947-1, screw terminals 1 x 2.5 mm² IEC 60947-1″},{“name”:”Output Short-Circuit Protection”,”normalizedValue”:”no”,”value”:”no”},{“name”:”Repeat Accuracy”,”normalizedValue”:”+/- 0.5 %”,”value”:”+/- 0.5 %”},{“name”:”Diameter”,”normalizedValue”:”29 mm”,”value”:”29 mm”},{“name”:”Immunity To Radioelectric Fields”,”normalizedValue”:”10 V level 3 IEC 61000-4-6″,”value”:”10 V level 3 IEC 61000-4-6″},{“name”:”Power Consumption In Va”,”normalizedValue”:”1.5 VA”,”value”:”1.5 VA”},{“name”:”Overvoltage Category”,”normalizedValue”:”class 3 IEC 60536, class 3 IEC 60664-1″,”value”:”class 3 IEC 60536, class 3 IEC 60664-1″},{“name”:”Output Type”,”normalizedValue”:”thyristor”,”value”:”thyristor”},{“name”:”Vibration Resistance”,”normalizedValue”:”0.15 mm 10-60 Hz)IEC 60068-2-6, 2 gn 60-150 Hz)IEC 60068-2-6″,”value”:”0.15 mm 10-60 Hz)IEC 60068-2-6, 2 gn 60-150 Hz)IEC 60068-2-6″},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”250 V IEC 60947-1, 250 V IEC 60664-1″,”value”:”250 V IEC 60947-1, 250 V IEC 60664-1″},{“name”:”Local Signalling”,”normalizedValue”:”LED green, steady timing in progress, LED, off no timing in progress and output relay energised”,”value”:”LED green, steady timing in progress, LED, off no timing in progress and output relay energised”},{“name”:”Resistance To Electromagnetic Fields”,”normalizedValue”:”10 V/m 80 MHz…1 GHz level 3 IEC 61000-4-3, 3 V/m 1.4…2 GHz level 2 IEC 61000-4-3, 1 V/m 2…2.7 GHz level 1 IEC 61000-4-3″,”value”:”10 V/m 80 MHz…1 GHz level 3 IEC 61000-4-3, 3 V/m 1.4…2 GHz level 2 IEC 61000-4-3, 1 V/m 2…2.7 GHz level 1 IEC 61000-4-3″},{“name”:”Resistance To Fast Transients”,”normalizedValue”:”2 kV level 3 IEC 61000-4-4″,”value”:”2 kV level 3 IEC 61000-4-4″},{“name”:”Shape of Signaling Unit Head”,”normalizedValue”:”round”,”value”:”round”},{“name”:”Power Consumption In W”,”normalizedValue”:”1 W”,”value”:”1 W”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-20-80°C”,”value”:”-20-80°C”},{“name”:”Maximum Residual Current”,”normalizedValue”:”5 mA”,”value”:”5 mA”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”France”,”value”:”France”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.