Outlet Strip, 20 A, 7 ft Cord L, 6 Outlets, LEVITON, Mfr# 5306M-2S7

$175,99

Surge Protected Outlet Strip, Total Number of Outlets 6, Cord Length 7 ft, Rated Joules 644, Application Hospital and Medical Facility, Housing Material Steel, Max. Amps 20 A, Power Indicator Yes, Receptacle Configuration Hospital Grade, Plug Configuration NEMA 5-20P, Medical Facility Use Patient Care – Only When Permanently Mounted (UL 1363A); Outside Patient Care Areas (UL 1449); Patient Care (UL 60601-1), Voltage 125V AC, Length 16 7/8 in

9999 in stock

SKU: GRG004186776 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Surge Protected Outlet Strip”,”rank”:1,”value”:”Surge Protected Outlet Strip”},{“name”:”Voltage”,”normalizedValue”:”125 V”,”rank”:4,”value”:”125V AC”},{“name”:”Cord Length”,”normalizedValue”:”7 ft”,”rank”:6,”value”:”7 ft”},{“name”:”Max. Amps”,”normalizedValue”:”20 A”,”rank”:9,”value”:”20 A”},{“name”:”Mounting Style”,”normalizedValue”:”Mounting Hole”,”rank”:10,”value”:”Mounting Hole”},{“name”:”Power Indicator”,”normalizedValue”:”Yes”,”rank”:11,”value”:”Yes”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”rank”:12,”value”:”Steel”},{“name”:”Noise Attenuation”,”normalizedValue”:”-6 to -29dB”,”value”:”-6 to -29dB”},{“name”:”Width”,”normalizedValue”:”2-5/8 in”,”value”:”2 5/8 in”},{“name”:”Height”,”normalizedValue”:”1-5/8 in”,”value”:”1 5/8 in”},{“name”:”Special Features”,”normalizedValue”:”Easily Accommodates Surface Mounting and IV Pole Mounting With the Use of the Mounting Bracket, Heavy Duty Steel Construction Withstands the Rigors of Demanding Environments, Locking Safety Covers are Splash-Resistant and Protect From Incidental Contact With Unused Outlets”,”value”:”Easily Accommodates Surface Mounting and IV Pole Mounting With the Use of the Mounting Bracket, Heavy Duty Steel Construction Withstands the Rigors of Demanding Environments, Locking Safety Covers are Splash-Resistant and Protect From Incidental Contact With Unused Outlets”},{“name”:”Standards”,”normalizedValue”:”ANSI/IEEE: Category A, NFPA: NFPA 99 2012 ed, UL 1363A and CSA C22.2: No. 21, UL 1449 3rd Ed and CSA C22.2: No. 8, UL 60601-1 and CSA C22.2: No.60601-1, UL 60950-1 and CSA C22.2: No. 60950-1″,”value”:”ANSI/IEEE: Category A, NFPA: NFPA 99 2012 ed, UL 1363A and CSA C22.2: No. 21, UL 1449 3rd Ed and CSA C22.2: No. 8, UL 60601-1 and CSA C22.2: No.60601-1, UL 60950-1 and CSA C22.2: No. 60950-1″},{“name”:”Medical Facility Use”,”normalizedValue”:”Patient Care – Only When Permanently Mounted (UL 1363A), Outside Patient Care Areas (UL 1449), Patient Care (UL 60601-1)”,”value”:”Patient Care – Only When Permanently Mounted (UL 1363A), Outside Patient Care Areas (UL 1449), Patient Care (UL 60601-1)”},{“name”:”Total Number of Outlets”,”normalizedValue”:”6″,”value”:”6″},{“name”:”For Use With”,”normalizedValue”:”Isolated Power Systems”,”value”:”Isolated Power Systems”},{“name”:”Plug Configuration”,”normalizedValue”:”NEMA 5-20P”,”value”:”NEMA 5-20P”},{“name”:”Surge Protection Indicator”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Receptacle Configuration”,”normalizedValue”:”Hospital Grade”,”value”:”Hospital Grade”},{“name”:”Application”,”normalizedValue”:”Hospital and Medical Facility”,”value”:”Hospital and Medical Facility”},{“name”:”Trade Designation”,”normalizedValue”:”SJT”,”value”:”SJT”},{“name”:”Length”,”normalizedValue”:”16-7/8 in”,”value”:”16 7/8 in”},{“name”:”Max. Surge Current”,”normalizedValue”:”27 kA”,”value”:”27 kA”},{“name”:”Rated Joules”,”normalizedValue”:”644″,”value”:”644″},{“name”:”Hz”,”normalizedValue”:”60″,”value”:”60 Hz”},{“name”:”Storage Temperature”,”normalizedValue”:”-10°C to +50°C”,”value”:”-10°C to +50°C”},{“name”:”Max Surge Current L-N”,”normalizedValue”:”27 kA”,”value”:”27kA”},{“name”:”UL 1363A \u0026 CSA C22.2″,”normalizedValue”:”No. 21″,”value”:”No. 21″},{“name”:”Outlet Covers”,”normalizedValue”:”Polypropylene”,”value”:”Polypropylene”},{“name”:”Operating Temperature”,”normalizedValue”:”0 to 40 deg C”,”value”:”0°C to 40°C”},{“name”:”HG Plug Configuration”,”normalizedValue”:”NEMA 5-20P”,”value”:”NEMA 5-20P”},{“name”:”Number of Receptacles”,”normalizedValue”:”6″,”value”:”6″},{“name”:”Surge Technology”,”normalizedValue”:”MOV”,”value”:”MOV”},{“name”:”Surge Protection”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Line Cord”,”normalizedValue”:”#12/3 SJT”,”value”:”#12/3 SJT”},{“name”:”UL 60950-1 \u0026 CSA C22.2″,”normalizedValue”:”No. 60950-1″,”value”:”No. 60950-1″},{“name”:”Frequency”,”normalizedValue”:”60Hz”,”value”:”60Hz”},{“name”:”Noise Filtering”,”normalizedValue”:”-6dB to -29dB (100kHz to 100MHz)”,”value”:”-6dB to -29dB (100kHz to 100MHz)”},{“name”:”Enclosure”,”normalizedValue”:”Powder Coated Steel”,”value”:”Powder Coated Steel”},{“name”:”Grade”,”normalizedValue”:”Medical”,”value”:”Medical”},{“name”:”Amperage”,”normalizedValue”:”20 A”,”value”:”20 A”},{“name”:”Maximum Leakage Current”,”normalizedValue”:”\u003c100µA”,”value”:”\u003c100µA”},{“name”:”Joules Rating”,”normalizedValue”:”644J”,”value”:”644J”},{“name”:”HG Outlet Configuration”,”normalizedValue”:”NEMA 5-20R”,”value”:”NEMA 5-20R”},{“name”:”Voltage Protection Rating (VPR) L-N, L-G, N-G”,”normalizedValue”:”600 V, 600 V, 500 V”,”value”:”600V, 600V, 500V”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Outlet Strip, 20 A, 7 ft Cord L, 6 Outlets, LEVITON, Mfr# 5306M-2S7”