Non-Metallic Underground Feeder Cable, UF-B, 6 AWG, 2C with Ground C, Gray, PVC, Stranded, 600V AC

$467,99

Underground Feeder Cable, Number of Conductors 2, Wire Size 6 AWG, Trade Designation UF-B, Jacket Material PVC, Jacket Color Gray, Length 125 ft, Conductor Design Stranded, Voltage 600 V, Wire Color Bare, Black, White, Nominal Outside Dia. 0.77 in x 0.30 in, Temp. Rating 194 Degrees F, Application Outside Post Lamps, Pumps, Standards REACH, RoHS, UL Listed, Insulation Material PVC with Nylon Covering, Packaging Spool

9999 in stock

SKU: GRG1984596 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Non-Metallic Underground Feeder Cable”,”rank”:1,”value”:”Non-Metallic Underground Feeder Cable”},{“name”:”Trade Designation”,”normalizedValue”:”UF-B”,”rank”:2,”value”:”UF-B”},{“name”:”Wire Size”,”normalizedValue”:”6 AWG”,”rank”:3,”value”:”6 AWG”},{“name”:”Conductor Material”,”normalizedValue”:”Copper”,”rank”:4,”value”:”Copper”},{“name”:”Number of Conductors”,”normalizedValue”:”2C with Ground”,”rank”:5,”value”:”2C with Ground”},{“name”:”Wire Color”,”normalizedValue”:”Bare/Black/White”,”rank”:6,”value”:”Bare/Black/White”},{“name”:”Jacket Color”,”normalizedValue”:”Gray”,”rank”:7,”value”:”Gray”},{“name”:”Jacket Material”,”normalizedValue”:”PVC”,”rank”:8,”value”:”PVC”},{“name”:”Conductor Design”,”normalizedValue”:”Stranded”,”rank”:10,”value”:”Stranded”},{“name”:”Insulation Material”,”normalizedValue”:”PVC”,”rank”:11,”value”:”PVC”},{“name”:”Voltage”,”normalizedValue”:”600V AC”,”rank”:12,”value”:”600V AC”},{“name”:”Length”,”normalizedValue”:”125 ft”,”rank”:13,”value”:”125 ft”},{“name”:”Temp. Rating”,”normalizedValue”:”194 deg F”,”rank”:14,”value”:”194°F”},{“name”:”Standards”,”normalizedValue”:”REACH, RoHS, UL Listed”,”rank”:15,”value”:”REACH, RoHS, UL Listed”},{“name”:”Overall Length”,”normalizedValue”:”125 ft”,”value”:”125 ft”},{“name”:”Stranding”,”normalizedValue”:”7, 1″,”value”:”7, 1″},{“name”:”Nominal Outside Dia.”,”normalizedValue”:”0.77 in x 0.30 in”,”value”:”0.77 in x 0.30 in”},{“name”:”Application”,”normalizedValue”:”Outside Post Lamps, Pumps”,”value”:”Outside Post Lamps, Pumps”},{“name”:”Packaging”,”normalizedValue”:”Spool”,”value”:”Spool”},{“name”:”Conductor Size”,”normalizedValue”:”6 AWG”,”value”:”6 AWG”},{“name”:”Nom. Width (Mils)”,”normalizedValue”:”769 mil”,”value”:”769mils”},{“name”:”Nom. Height (Mils)”,”normalizedValue”:”338 mil”,”value”:”338mils”},{“name”:”Insulation Thickness (Mils)”,”normalizedValue”:”30 mil”,”value”:”30mils”},{“name”:”Applications”,”normalizedValue”:”ApplicationSouthwire® copper UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the 2011 National Electrical Code. UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code. UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 volts.”,”value”:”ApplicationSouthwire® copper UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the 2011 National Electrical Code. UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code. UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 volts.”},{“name”:”Construction”,”normalizedValue”:”ConstructionSouthwire® copper UF-B cable is manufactured as a 2 or 3 conductor cable, with or without a ground wire. Copper conductors are annealed (soft) copper, solid or compressed stranded. Phase conductors are polyvinyl chloride (PVC) insulated, nylon jacketed, color coded for identification purposes. Jacketed with sunlight, moisture and fungus resistant gray PVC.”,”value”:”ConstructionSouthwire® copper UF-B cable is manufactured as a 2 or 3 conductor cable, with or without a ground wire. Copper conductors are annealed (soft) copper, solid or compressed stranded. Phase conductors are polyvinyl chloride (PVC) insulated, nylon jacketed, color coded for identification purposes. Jacketed with sunlight, moisture and fungus resistant gray PVC.”},{“name”:”Nominal Outside Diameter”,”normalizedValue”:”0.77 in x 0.30 in”,”value”:”0.77 in x 0.30 in”},{“name”:”Grounding Conductor Size”,”normalizedValue”:”10 AWG”,”value”:”10 AWG”},{“name”:”Number of Ground Conductors”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Temperature Rating – Maximum Dry”,”normalizedValue”:”194 deg F”,”value”:”194 Degrees F”},{“name”:”Conductor Insulation Material”,”normalizedValue”:”Nylon, PVC”,”value”:”Nylon, PVC”},{“name”:”Grounding Conductor Material”,”normalizedValue”:”Copper”,”value”:”Copper”},{“name”:”Temperature Rating – Maximum Wet”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Minimum Bend Radius”,”normalizedValue”:”3-1/8 in”,”value”:”3 1/8 in”},{“name”:”Grounding Conductor Insulation Color”,”normalizedValue”:”Bare”,”value”:”Bare”},{“name”:”Conductor Insulation Color”,”normalizedValue”:”White, Black”,”value”:”Black, White”},{“name”:”Number of Strands”,”normalizedValue”:”7″,”value”:”7″},{“name”:”Grounding Conductor Insulation Material”,”normalizedValue”:”Uninsulated”,”value”:”Uninsulated”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Non-Metallic Underground Feeder Cable, UF-B, 6 AWG, 2C with Ground C, Gray, PVC, Stranded, 600V AC”