Description
[{“name”:”Item”,”normalizedValue”:”Non-Metallic Underground Feeder Cable”,”rank”:1,”value”:”Non-Metallic Underground Feeder Cable”},{“name”:”Trade Designation”,”normalizedValue”:”UF-B”,”rank”:2,”value”:”UF-B”},{“name”:”Wire Size”,”normalizedValue”:”12 AWG”,”rank”:3,”value”:”12 AWG”},{“name”:”Conductor Material”,”normalizedValue”:”Copper”,”rank”:4,”value”:”Copper”},{“name”:”Number of Conductors”,”normalizedValue”:”2C with Ground”,”rank”:5,”value”:”2C with Ground”},{“name”:”Wire Color”,”normalizedValue”:”Bare/Black/White”,”rank”:6,”value”:”Bare/Black/White”},{“name”:”Jacket Color”,”normalizedValue”:”Gray”,”rank”:7,”value”:”Gray”},{“name”:”Jacket Material”,”normalizedValue”:”PVC”,”rank”:8,”value”:”PVC”},{“name”:”Conductor Design”,”normalizedValue”:”Solid”,”rank”:10,”value”:”Solid”},{“name”:”Insulation Material”,”normalizedValue”:”PVC”,”rank”:11,”value”:”PVC”},{“name”:”Voltage”,”normalizedValue”:”600V AC”,”rank”:12,”value”:”600V AC”},{“name”:”Length”,”normalizedValue”:”250 ft”,”rank”:13,”value”:”250 ft”},{“name”:”Temp. Rating”,”normalizedValue”:”194 deg F”,”rank”:14,”value”:”194°F”},{“name”:”Standards”,”normalizedValue”:”UL Standard 83 and UL Standard 493″,”rank”:15,”value”:”UL Standard 83 and UL Standard 493″},{“name”:”Application”,”normalizedValue”:”Outside Post Lamps, Pumps”,”value”:”Outside Post Lamps, Pumps”},{“name”:”Nominal Outside Dia.”,”normalizedValue”:”0.46 in x 0.18 in”,”value”:”0.46 in x 0.18 in”},{“name”:”Max. Amps”,”normalizedValue”:”20″,”value”:”20″},{“name”:”Conductor Size”,”normalizedValue”:”12 AWG”,”value”:”12 AWG”},{“name”:”Stranding”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Packaging”,”normalizedValue”:”Coil”,”value”:”Coil”},{“name”:”Overall Length”,”normalizedValue”:”250 ft”,”value”:”250 ft”},{“name”:”Applications”,”normalizedValue”:”ApplicationSouthwire® copper UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the 2011 National Electrical Code. UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code. UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 volts.”,”value”:”ApplicationSouthwire® copper UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the 2011 National Electrical Code. UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code. UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 volts.”},{“name”:”Nom. Height (Mils)”,”normalizedValue”:”183 mil”,”value”:”183mils”},{“name”:”Jacket Thickness (Mils)”,”normalizedValue”:”30 mil”,”value”:”30mils”},{“name”:”Insulation Thickness (Mils)”,”normalizedValue”:”15 mil”,”value”:”15mils”},{“name”:”Construction”,”normalizedValue”:”ConstructionSouthwire® copper UF-B cable is manufactured as a 2 or 3 conductor cable, with or without a ground wire. Copper conductors are annealed (soft) copper, solid or compressed stranded. Phase conductors are polyvinyl chloride (PVC) insulated, nylon jacketed, color coded for identification purposes. Jacketed with sunlight, moisture and fungus resistant gray PVC.”,”value”:”ConstructionSouthwire® copper UF-B cable is manufactured as a 2 or 3 conductor cable, with or without a ground wire. Copper conductors are annealed (soft) copper, solid or compressed stranded. Phase conductors are polyvinyl chloride (PVC) insulated, nylon jacketed, color coded for identification purposes. Jacketed with sunlight, moisture and fungus resistant gray PVC.”},{“name”:”Nom. Width (Mils)”,”normalizedValue”:”463 mil”,”value”:”463mils”},{“name”:”Conductor Insulation Material”,”normalizedValue”:”Nylon, PVC”,”value”:”Nylon, PVC”},{“name”:”Minimum Bend Radius”,”normalizedValue”:”1-7/8 in”,”value”:”1 7/8 in”},{“name”:”Grounding Conductor Insulation Color”,”normalizedValue”:”Bare”,”value”:”Bare”},{“name”:”Temperature Rating – Maximum Dry”,”normalizedValue”:”194 deg F”,”value”:”194 Degrees F”},{“name”:”Nominal Outside Diameter”,”normalizedValue”:”0.46 in x 0.18 in”,”value”:”0.46 in x 0.18 in”},{“name”:”Number of Ground Conductors”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Grounding Conductor Material”,”normalizedValue”:”Copper”,”value”:”Copper”},{“name”:”Temperature Rating – Maximum Wet”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Grounding Conductor Insulation Material”,”normalizedValue”:”Uninsulated”,”value”:”Uninsulated”},{“name”:”Grounding Conductor Size”,”normalizedValue”:”12 AWG”,”value”:”12 AWG”},{“name”:”Conductor Insulation Color”,”normalizedValue”:”White, Black”,”value”:”Black, White”},{“name”:”Number of Strands”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.