120VAC Non-Reversing Magnetic Contactor 2P 18A NEMA 0, Square D, Mfr#: 8502SBO1V02S

$333,99

NEMA Magnetic Contactor, Auxiliary Contact Form Auxiliary Contacts Not Included, NEMA Enclosure Rating No Enclosure, NEMA Size 0, Coil Voltage 120V AC, Number of Poles 2, Full Load Current – Inductive 18 A, Reversing Capability Non-Reversing, Overall Height 4.34 in, Overall Width 3.22 in, Terminal Connection Type Screw Clamp Terminals, Series 8502, Number of Auxillary Contacts 0, Contactor Style NEMA, Phase Single, Horsepower @ Single Phase – 240V AC 2 hp

9999 in stock

SKU: GRG1155506 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Magnetic Contactor”,”rank”:1,”value”:”Magnetic Contactor”},{“name”:”Full Load Amps”,”normalizedValue”:”18 A”,”rank”:2,”value”:”18 A”},{“name”:”Action”,”normalizedValue”:”Non-Reversing”,”rank”:2,”value”:”Non-Reversing”},{“name”:”Number of Poles”,”normalizedValue”:”2″,”rank”:3,”value”:”2″},{“name”:”NEMA Contactor Size”,”normalizedValue”:”0″,”rank”:4,”value”:”0″},{“name”:”Coil Volts”,”normalizedValue”:”120 V AC”,”rank”:4,”value”:”120V AC”},{“name”:”Reversing”,”normalizedValue”:”No”,”rank”:5,”value”:”No”},{“name”:”HP @ 1 Phase – 120V”,”normalizedValue”:”1 hp”,”rank”:6,”value”:”1 hp”},{“name”:”HP @ 1 Phase – 240V”,”normalizedValue”:”2 hp”,”rank”:7,”value”:”2 hp”},{“name”:”Height”,”normalizedValue”:”4.34 in”,”rank”:7,”value”:”4.34 in”},{“name”:”Width”,”normalizedValue”:”3.22 in”,”rank”:8,”value”:”3.22 in”},{“name”:”Depth”,”normalizedValue”:”4.22 in”,”rank”:9,”value”:”4.22 in”},{“name”:”Enclosure NEMA Rating”,”normalizedValue”:”No Enclosure”,”rank”:10,”value”:”No Enclosure”},{“name”:”NEMA Size”,”normalizedValue”:”0″,”value”:”0″},{“name”:”Frame / Series / Class / Code”,”normalizedValue”:”Class 8502″,”value”:”Class 8502″},{“name”:”Standards”,”normalizedValue”:”CSA, UL E78351 CCN NLDX”,”value”:”CSA, UL E78351 CCN NLDX”},{“name”:”Hz”,”normalizedValue”:”50/60″,”value”:”50/60″},{“name”:”Series”,”normalizedValue”:”8502″,”value”:”8502″},{“name”:”Auxiliary Contact Form”,”normalizedValue”:”Auxiliary Contacts Not Included”,”value”:”Auxiliary Contacts Not Included”},{“name”:”[Ue] Rated Operational Voltage”,”normalizedValue”:”600 V AC”,”value”:”600 V AC”},{“name”:”Contactor Application”,”normalizedValue”:”non-reversing”,”value”:”non-reversing”},{“name”:”Auxiliary Contact Composition”,”normalizedValue”:”without”,”value”:”without”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Local Signalling”,”normalizedValue”:”no indicator”,”value”:”no indicator”},{“name”:”Product Compatibility”,”normalizedValue”:”circuit-breaker 70 A maximum, SCCR: 100 kA at 480 V AC || fuse J 60 A maximum, SCCR: 100 kA at 600 V AC || fuse T 60 A maximum, SCCR: 100 kA at 600 V AC || fuse RK1 60 A maximum, SCCR: 100 kA at 600 V AC || fuse RK5 60 A maximum, SCCR: 100 kA at 600 V AC”,”value”:”circuit-breaker 70 A maximum, SCCR: 100 kA at 480 V AC || fuse J 60 A maximum, SCCR: 100 kA at 600 V AC || fuse T 60 A maximum, SCCR: 100 kA at 600 V AC || fuse RK1 60 A maximum, SCCR: 100 kA at 600 V AC || fuse RK5 60 A maximum, SCCR: 100 kA at 600 V AC”},{“name”:”Nema Degree Of Protection”,”normalizedValue”:”not rated (open device)”,”value”:”not rated (open device)”},{“name”:”Control Circuit”,”normalizedValue”:”Separate control circuit”,”value”:”separate control circuit”},{“name”:”Control Type”,”normalizedValue”:”No control units”,”value”:”no control units”},{“name”:”Electrical Connection”,”normalizedValue”:”Screw Clamp Terminals”,”value”:”screw clamp terminals”},{“name”:”Product Certifications”,”normalizedValue”:”UL listed file E78351 CCN NLDX || CSA”,”value”:”UL listed file E78351 CCN NLDX || CSA”},{“name”:”[Uc] Control Circuit Voltage”,”normalizedValue”:”120 V AC 60 Hz || 110 V AC 50 Hz”,”value”:”120 V AC 60 Hz || 110 V AC 50 Hz”},{“name”:”Rated Power In Hp”,”normalizedValue”:”1 HP 115 V AC || 2 HP 230 V AC”,”value”:”1 HP 115 V AC || 2 HP 230 V AC”},{“name”:”Product Or Component Type”,”normalizedValue”:”Contactor”,”value”:”contactor”},{“name”:”Line Rated Current”,”normalizedValue”:”18 A”,”value”:”18 A”},{“name”:”Poles Description”,”normalizedValue”:”2P”,”value”:”2P”},{“name”:”Embedded Surge Suppressor”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Reversing Capability”,”normalizedValue”:”Non-Reversing”,”value”:”Non-Reversing”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”No Enclosure”,”value”:”No Enclosure”},{“name”:”Coil Voltage”,”normalizedValue”:”120V AC”,”value”:”120V AC”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Horsepower @ Single Phase – 120V AC”,”normalizedValue”:”1 HP”,”value”:”1 hp”},{“name”:”Number of Auxillary Contacts”,”normalizedValue”:”0″,”value”:”0″},{“name”:”Maximum Voltage Rating”,”normalizedValue”:”600 V AC”,”value”:”600V AC”},{“name”:”Includes Auxiliary Contacts”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Terminal Connection Type”,”normalizedValue”:”Screw Clamp Terminals”,”value”:”Screw Clamp Terminals”},{“name”:”Overall Height”,”normalizedValue”:”4.34 in”,”value”:”4.34 in”},{“name”:”Horsepower @ Single Phase – 240V AC”,”normalizedValue”:”2 HP”,”value”:”2 hp”},{“name”:”Full Load Current – Inductive”,”normalizedValue”:”18 A”,”value”:”18 A”},{“name”:”Contactor Style”,”normalizedValue”:”NEMA”,”value”:”NEMA”},{“name”:”Overall Depth”,”normalizedValue”:”4.22 in”,”value”:”4.22 in”},{“name”:”Overall Width”,”normalizedValue”:”3.22 in”,”value”:”3.22 in”},{“name”:”NEMA Enclosure Material”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “120VAC Non-Reversing Magnetic Contactor 2P 18A NEMA 0, Square D, Mfr#: 8502SBO1V02S”