Description
[{“name”:”Item”,”normalizedValue”:”Magnetic Contactor”,”rank”:1,”value”:”Magnetic Contactor”},{“name”:”Action”,”normalizedValue”:”Non-Reversing”,”rank”:2,”value”:”Non-Reversing”},{“name”:”Full Load Amps”,”normalizedValue”:”45 A”,”rank”:2,”value”:”45 A”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”rank”:3,”value”:”3″},{“name”:”Coil Volts”,”normalizedValue”:”120 V AC”,”rank”:4,”value”:”120V AC”},{“name”:”NEMA Contactor Size”,”normalizedValue”:”2″,”rank”:4,”value”:”2″},{“name”:”Reversing”,”normalizedValue”:”No”,”rank”:5,”value”:”No”},{“name”:”Height”,”normalizedValue”:”5.13 in”,”rank”:7,”value”:”5.13 in”},{“name”:”HP @ 3 Phase – 208V”,”normalizedValue”:”10 hp”,”rank”:8,”value”:”10 hp”},{“name”:”Width”,”normalizedValue”:”4.31 in”,”rank”:8,”value”:”4.31 in”},{“name”:”Depth”,”normalizedValue”:”4.94 in”,”rank”:9,”value”:”4.94 in”},{“name”:”HP @ 3 Phase – 575V”,”normalizedValue”:”25 hp”,”rank”:9,”value”:”25 hp”},{“name”:”HP @ 3 Phase – 240V”,”normalizedValue”:”15 hp”,”rank”:9,”value”:”15 hp”},{“name”:”HP @ 3 Phase – 480V”,”normalizedValue”:”25 hp”,”rank”:10,”value”:”25 hp”},{“name”:”Enclosure NEMA Rating”,”normalizedValue”:”No Enclosure”,”rank”:10,”value”:”No Enclosure”},{“name”:”NEMA Size”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Standards”,”normalizedValue”:”CSA, UL E78351 CCN NLDX”,”value”:”CSA, UL E78351 CCN NLDX”},{“name”:”Frame / Series / Class / Code”,”normalizedValue”:”Class 8502″,”value”:”Class 8502″},{“name”:”Hz”,”normalizedValue”:”50/60″,”value”:”50/60″},{“name”:”Auxiliary Contact Form”,”normalizedValue”:”Auxiliary Contacts Not Included”,”value”:”Auxiliary Contacts Not Included”},{“name”:”Series”,”normalizedValue”:”8502″,”value”:”8502″},{“name”:”Product Certifications”,”normalizedValue”:”UL listed file E78351 CCN NLDX || CSA”,”value”:”UL listed file E78351 CCN NLDX || CSA”},{“name”:”Product Compatibility”,”normalizedValue”:”circuit-breaker 100 A maximum, SCCR: 100 kA at 480 V AC || fuse J 100 A maximum, SCCR: 100 kA at 600 V AC || fuse T 100 A maximum, SCCR: 100 kA at 600 V AC || fuse RK1 100 A maximum, SCCR: 100 kA at 600 V AC || fuse RK5 100 A maximum, SCCR: 100 kA at 600 V AC”,”value”:”circuit-breaker 100 A maximum, SCCR: 100 kA at 480 V AC || fuse J 100 A maximum, SCCR: 100 kA at 600 V AC || fuse T 100 A maximum, SCCR: 100 kA at 600 V AC || fuse RK1 100 A maximum, SCCR: 100 kA at 600 V AC || fuse RK5 100 A maximum, SCCR: 100 kA at 600 V AC”},{“name”:”Control Circuit”,”normalizedValue”:”Separate control circuit”,”value”:”separate control circuit”},{“name”:”Control Type”,”normalizedValue”:”No control units”,”value”:”no control units”},{“name”:”Line Rated Current”,”normalizedValue”:”45 A”,”value”:”45 A”},{“name”:”Contactor Application”,”normalizedValue”:”non-reversing”,”value”:”non-reversing”},{“name”:”Auxiliary Contact Composition”,”normalizedValue”:”without”,”value”:”without”},{“name”:”Nema Degree Of Protection”,”normalizedValue”:”not rated (open device)”,”value”:”not rated (open device)”},{“name”:”Phase”,”normalizedValue”:”Three”,”value”:”Three”},{“name”:”[Uc] Control Circuit Voltage”,”normalizedValue”:”120 V AC 60 Hz || 110 V AC 50 Hz”,”value”:”120 V AC 60 Hz || 110 V AC 50 Hz”},{“name”:”Poles Description”,”normalizedValue”:”3P”,”value”:”3P”},{“name”:”[Ue] Rated Operational Voltage”,”normalizedValue”:”600 V AC”,”value”:”600 V AC”},{“name”:”Local Signalling”,”normalizedValue”:”no indicator”,”value”:”no indicator”},{“name”:”Electrical Connection”,”normalizedValue”:”Screw Clamp Terminals”,”value”:”screw clamp terminals”},{“name”:”Product Or Component Type”,”normalizedValue”:”Contactor”,”value”:”contactor”},{“name”:”Rated Power In Hp”,”normalizedValue”:”10 HP 200 V AC || 15 HP 230 V AC || 25 HP 460 V AC || 25 HP 575 V AC”,”value”:”10 HP 200 V AC || 15 HP 230 V AC || 25 HP 460 V AC || 25 HP 575 V AC”},{“name”:”Horsepower @ Three Phase – 208V AC”,”normalizedValue”:”10 HP”,”value”:”10 hp”},{“name”:”Coil Voltage”,”normalizedValue”:”120V AC”,”value”:”120V AC”},{“name”:”Full Load Current – Inductive”,”normalizedValue”:”45 A”,”value”:”45 A”},{“name”:”Reversing Capability”,”normalizedValue”:”Non-Reversing”,”value”:”Non-Reversing”},{“name”:”Terminal Connection Type”,”normalizedValue”:”Screw Clamp Terminals”,”value”:”Screw Clamp Terminals”},{“name”:”Number of Auxillary Contacts”,”normalizedValue”:”0″,”value”:”0″},{“name”:”Overall Depth”,”normalizedValue”:”4.94 in”,”value”:”4.94 in”},{“name”:”Maximum Voltage Rating”,”normalizedValue”:”600 V AC”,”value”:”600V AC”},{“name”:”Includes Auxiliary Contacts”,”normalizedValue”:”No”,”value”:”No”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”No Enclosure”,”value”:”No Enclosure”},{“name”:”Horsepower @ Three Phase – 480V AC”,”normalizedValue”:”25 HP”,”value”:”25 hp”},{“name”:”Horsepower @ Three Phase – 240V AC”,”normalizedValue”:”15 HP”,”value”:”15 hp”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”NEMA Enclosure Material”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Contactor Style”,”normalizedValue”:”NEMA”,”value”:”NEMA”},{“name”:”Embedded Surge Suppressor”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Horsepower @ Single Phase – 240V AC”,”normalizedValue”:”15 HP”,”value”:”15 hp”},{“name”:”Overall Width”,”normalizedValue”:”4.31 in”,”value”:”4.31 in”},{“name”:”Horsepower @ Three Phase – 600V AC”,”normalizedValue”:”25 HP”,”value”:”25 hp”},{“name”:”Overall Height”,”normalizedValue”:”5.13 in”,”value”:”5.13 in”},{“name”:”Horsepower Rating”,”normalizedValue”:”10 HP 200 V AC; 15 HP 230 V AC; 25 HP 460 V AC; 25 HP 575 V AC”,”value”:”10 HP 200 V AC; 15 HP 230 V AC; 25 HP 460 V AC; 25 HP 575 V AC”},{“name”:”Certifications”,”normalizedValue”:”UL listed file E78351 CCN NLDX; CSA”,”value”:”UL listed file E78351 CCN NLDX; CSA”},{“name”:”Short Circuit Current Rating”,”normalizedValue”:”Circuit-breaker 100 A maximum, SCCR: 100 kA at 480 V AC; Fuse J 100 A maximum, SCCR: 100 kA at 600 V AC; Fuse T 100 A maximum, SCCR: 100 kA at 600 V AC; Fuse RK1 100 A maximum, SCCR: 100 kA at 600 V AC; Fuse RK5 100 A maximum, SCCR: 100 kA at 600 V AC”,”value”:”Circuit-breaker 100 A maximum, SCCR: 100 kA at 480 V AC; Fuse J 100 A maximum, SCCR: 100 kA at 600 V AC; Fuse T 100 A maximum, SCCR: 100 kA at 600 V AC; Fuse RK1 100 A maximum, SCCR: 100 kA at 600 V AC; Fuse RK5 100 A maximum, SCCR: 100 kA at 600 V AC”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.