NEMA Control Relay, Type X, machine tool, 10A resistive at 600 VAC, 4 normally open contacts, 110/120 VAC 50/60 Hz coil

$196,99

NEMA Control Relay,machine tool,4 NO,

Out of stock

SKU: GRG5526203 Category:

Description

[{“name”:”Item”,”normalizedValue”:”NEMA Control Relay,machine tool,4 NO,”,”value”:”NEMA Control Relay,machine tool,4 NO,”},{“name”:”Width”,”normalizedValue”:”2.23 in”,”value”:”2.23 in”},{“name”:”Depth”,”normalizedValue”:”3.95 in”,”value”:”3.95 in”},{“name”:”Height”,”normalizedValue”:”3-1/2 in”,”value”:”3.5 in”},{“name”:”Line Rated Current”,”normalizedValue”:”10 A AC || 5 A DC”,”value”:”10 A AC || 5 A DC”},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”operational 0.85…1.1 Uc AC 50/60 Hz”,”value”:”operational 0.85…1.1 Uc AC 50/60 Hz”},{“name”:”Product Certifications”,”normalizedValue”:”UL listed file E78403 CCN NKCR || CSA LR60905 class 3211 03″,”value”:”UL listed file E78403 CCN NKCR || CSA LR60905 class 3211 03″},{“name”:”Product Or Component Type”,”normalizedValue”:”relay”,”value”:”relay”},{“name”:”[Uc] Control Circuit Voltage”,”normalizedValue”:”110 V AC 50 Hz || 120 V AC 60 Hz”,”value”:”110 V AC 50 Hz || 120 V AC 60 Hz”},{“name”:”Hold-In Power Consumption In Va”,”normalizedValue”:”23-23 VA 60 Hz || 25-25 VA 50 Hz”,”value”:”23-23 VA 60 Hz || 25-25 VA 50 Hz”},{“name”:”Mounting Support”,”normalizedValue”:”panel”,”value”:”panel”},{“name”:”Tightening Torque”,”normalizedValue”:”control circuit 1.02-1.36 N.m screw terminals”,”value”:”control circuit 1.02-1.36 N.m screw terminals”},{“name”:”Operating Time”,”normalizedValue”:”15 ms – pick-up || 16 ms – drop-out”,”value”:”15 ms – pick-up || 16 ms – drop-out”},{“name”:”[Icm] Rated Short-Circuit Making Capacity”,”normalizedValue”:”60 A 120 V AC inductive control circuit UL 508 || 0.8 A 250 V DC resistive control circuit UL 508 || 30 A 240 V AC inductive control circuit UL 508 || 15 A 480 V AC inductive control circuit UL 508 || 12 A 600 V AC inductive control circuit UL 508 || 10 A \u003c= 600 V AC resistive control circuit UL 508 || 1.1 A 125 V DC inductive control circuit UL 508 || 0.55 A 250 V DC inductive control circuit UL 508 || 0.2 A 301…600 V DC inductive control circuit UL 508 || 4 A 125 V DC inductive control circuit UL 508″,”value”:”60 A 120 V AC inductive control circuit UL 508 || 0.8 A 250 V DC resistive control circuit UL 508 || 30 A 240 V AC inductive control circuit UL 508 || 15 A 480 V AC inductive control circuit UL 508 || 12 A 600 V AC inductive control circuit UL 508 || 10 A \u003c= 600 V AC resistive control circuit UL 508 || 1.1 A 125 V DC inductive control circuit UL 508 || 0.55 A 250 V DC inductive control circuit UL 508 || 0.2 A 301…600 V DC inductive control circuit UL 508 || 4 A 125 V DC inductive control circuit UL 508″},{“name”:”Inrush Power In Va”,”normalizedValue”:”148-148 VA 60 Hz || 143-143 VA 50 Hz”,”value”:”148-148 VA 60 Hz || 143-143 VA 50 Hz”},{“name”:”Relay Type”,”normalizedValue”:”control relay”,”value”:”control”},{“name”:”Contacts Type And Composition”,”normalizedValue”:”standard contact cartridges”,”value”:”4 NO 4 standard contact cartridges”},{“name”:”Awg Gauge”,”normalizedValue”:”AWG 18…AWG 12 copper”,”value”:”AWG 18…AWG 12 copper”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-40-160°F”,”value”:”-40-160°F”},{“name”:”Rated Breaking Capacity”,”normalizedValue”:”6 A 120 V AC inductive control circuit UL 508 || 0.8 A 250 V DC resistive control circuit UL 508 || 3 A 240 V AC inductive control circuit UL 508 || 1.5 A 480 V AC inductive control circuit UL 508 || 1.2 A 600 V AC inductive control circuit UL 508 || 10 A \u003c= 600 V AC resistive control circuit UL 508 || 1.1 A 125 V DC inductive control circuit UL 508 || 0.55 A 250 V DC inductive control circuit UL 508 || 0.2 A 301…600 V DC inductive control circuit UL 508 || 4 A 125 V DC resistive control circuit UL 508″,”value”:”6 A 120 V AC inductive control circuit UL 508 || 0.8 A 250 V DC resistive control circuit UL 508 || 3 A 240 V AC inductive control circuit UL 508 || 1.5 A 480 V AC inductive control circuit UL 508 || 1.2 A 600 V AC inductive control circuit UL 508 || 10 A \u003c= 600 V AC resistive control circuit UL 508 || 1.1 A 125 V DC inductive control circuit UL 508 || 0.55 A 250 V DC inductive control circuit UL 508 || 0.2 A 301…600 V DC inductive control circuit UL 508 || 4 A 125 V DC resistive control circuit UL 508″},{“name”:”Electrical Connection”,”normalizedValue”:”ring tongue”,”value”:”ring tongue”},{“name”:”Range of Product”,”normalizedValue”:”8501X”,”value”:”8501X”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “NEMA Control Relay, Type X, machine tool, 10A resistive at 600 VAC, 4 normally open contacts, 110/120 VAC 50/60 Hz coil”