Description
[{“name”:”Standards”,”normalizedValue”:”CSA LR60905 class 3211 03, UL listed file E78403 CCN NKCR”,”value”:”CSA LR60905 class 3211 03, UL listed file E78403 CCN NKCR”},{“name”:”Item”,”normalizedValue”:”NEMA Control Relay,2 NO,120 VAC 60 Hz”,”value”:”NEMA Control Relay,2 NO,120 VAC 60 Hz”},{“name”:”Depth”,”normalizedValue”:”3.95 in”,”value”:”3.95 in”},{“name”:”Width”,”normalizedValue”:”2.23 in”,”value”:”2.23 in”},{“name”:”Height”,”normalizedValue”:”3-1/2 in”,”value”:”3.5 in”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-40-160°F”,”value”:”-40-160°F”},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”operational 0.85…1.1 Uc AC 50/60 Hz”,”value”:”operational 0.85…1.1 Uc AC 50/60 Hz”},{“name”:”Mounting Support”,”normalizedValue”:”panel”,”value”:”panel”},{“name”:”Tightening Torque”,”normalizedValue”:”control circuit 1.02-1.36 N.m screw terminals”,”value”:”control circuit 1.02-1.36 N.m screw terminals”},{“name”:”Rated Breaking Capacity”,”normalizedValue”:”6 A 120 V AC inductive control circuit UL 508, 0.8 A 250 V DC resistive control circuit UL 508, 3 A 240 V AC inductive control circuit UL 508, 1.5 A 480 V AC inductive control circuit UL 508, 1.2 A 600 V AC inductive control circuit UL 508, 10 A <= 600 V AC resistive control circuit UL 508, 1.1 A 125 V DC inductive control circuit UL 508, 0.55 A 250 V DC inductive control circuit UL 508, 0.2 A 301...600 V DC inductive control circuit UL 508, 4 A 125 V DC resistive control circuit UL 508","value":"6 A 120 V AC inductive control circuit UL 508, 0.8 A 250 V DC resistive control circuit UL 508, 3 A 240 V AC inductive control circuit UL 508, 1.5 A 480 V AC inductive control circuit UL 508, 1.2 A 600 V AC inductive control circuit UL 508, 10 A <= 600 V AC resistive control circuit UL 508, 1.1 A 125 V DC inductive control circuit UL 508, 0.55 A 250 V DC inductive control circuit UL 508, 0.2 A 301...600 V DC inductive control circuit UL 508, 4 A 125 V DC resistive control circuit UL 508"},{"name":"Line Rated Current","normalizedValue":"10 A, 5 A","value":"10 A AC, 5 A DC"},{"name":"Inrush Power In Va","normalizedValue":"148-148 VA 60 Hz, 143-143 VA 50 Hz","value":"148-148 VA 60 Hz, 143-143 VA 50 Hz"},{"name":"Electrical Connection","normalizedValue":"ring tongue","value":"ring tongue"},{"name":"Relay Type","normalizedValue":"control","value":"control"},{"name":"Awg Gauge","normalizedValue":"AWG 18...AWG 12 copper","value":"AWG 18...AWG 12 copper"},{"name":"Operating Time","normalizedValue":"15 ms - pick-up, 16 ms - drop-out","value":"15 ms - pick-up, 16 ms - drop-out"},{"name":"[Uc] Control Circuit Voltage","normalizedValue":"110 V AC 50 Hz, 120 V AC 60 Hz","value":"110 V AC 50 Hz, 120 V AC 60 Hz"},{"name":"Hold-In Power Consumption In Va","normalizedValue":"23-23 VA 60 Hz, 25-25 VA 50 Hz","value":"23-23 VA 60 Hz, 25-25 VA 50 Hz"},{"name":"Product or Component Type","normalizedValue":"relay","value":"relay"},{"name":"Contacts Type And Composition","normalizedValue":"standard contact cartridges","value":"2 NO 2 standard contact cartridges"},{"name":"Range of Product","normalizedValue":"8501X","value":"8501X"},{"name":"[Icm] Rated Short-Circuit Making Capacity","normalizedValue":"60 A 120 V AC inductive control circuit UL 508, 0.8 A 250 V DC resistive control circuit UL 508, 30 A 240 V AC inductive control circuit UL 508, 15 A 480 V AC inductive control circuit UL 508, 12 A 600 V AC inductive control circuit UL 508, 10 A <= 600 V AC resistive control circuit UL 508, 1.1 A 125 V DC inductive control circuit UL 508, 0.55 A 250 V DC inductive control circuit UL 508, 0.2 A 301...600 V DC inductive control circuit UL 508, 4 A 125 V DC inductive control circuit UL 508","value":"60 A 120 V AC inductive control circuit UL 508, 0.8 A 250 V DC resistive control circuit UL 508, 30 A 240 V AC inductive control circuit UL 508, 15 A 480 V AC inductive control circuit UL 508, 12 A 600 V AC inductive control circuit UL 508, 10 A <= 600 V AC resistive control circuit UL 508, 1.1 A 125 V DC inductive control circuit UL 508, 0.55 A 250 V DC inductive control circuit UL 508, 0.2 A 301...600 V DC inductive control circuit UL 508, 4 A 125 V DC inductive control circuit UL 508"},{"name":"Product Certifications","normalizedValue":"CSA LR60905 class 3211 03 || UL listed file E78403 CCN NKCR","value":"CSA LR60905 class 3211 03 || UL listed file E78403 CCN NKCR"},{"name":"Product Or Component Type","normalizedValue":"relay","value":"relay"},{"name":"Country of Origin (subject to change)","normalizedValue":"Mexico","value":"Mexico"},{"name":"Package Quantity","normalizedValue":"1","value":"1"}]

Reviews
There are no reviews yet.