Description
[{“name”:”Standards”,”normalizedValue”:”IEC 61812-1 || EN 50081-1/2 || 93/68/EEC || 89/336/EEC || EN 50082-1/2 || IEC 60669-2-3 || 73/23/EEC”,”value”:”IEC 61812-1 || EN 50081-1/2 || 93/68/EEC || 89/336/EEC || EN 50082-1/2 || IEC 60669-2-3 || 73/23/EEC”},{“name”:”Item”,”normalizedValue”:”Timer,250VAC,5A,Re48 +options”,”value”:”Timer,250VAC,5A,Re48 +options”},{“name”:”Width”,”normalizedValue”:”48 mm”,”value”:”48 mm”},{“name”:”Output Voltage”,”normalizedValue”:”240 V 5 A AC-12 || 30 V 2 A DC-13 || 240 V 1.5 A AC-15″,”value”:”240 V 5 A AC-12 || 30 V 2 A DC-13 || 240 V 1.5 A AC-15″},{“name”:”Reset Time”,”normalizedValue”:”25 ms on de-energisation”,”value”:”25 ms on de-energisation”},{“name”:”Time Delay Type”,”normalizedValue”:”power on-delay || interval || off-delay || symmetrical flashing”,”value”:”power on-delay || interval || off-delay || symmetrical flashing”},{“name”:”Discrete Output Type”,”normalizedValue”:”relay”,”value”:”relay”},{“name”:”Product Certifications”,”normalizedValue”:”UL || cULus || CSA || C-tick”,”value”:”UL || cULus || CSA || C-tick”},{“name”:”Temperature Drift”,”normalizedValue”:”+/- 0.02 %/°C of the maximum setting value IEC 61812-1″,”value”:”+/- 0.02 %/°C of the maximum setting value IEC 61812-1″},{“name”:”Housing Material”,”normalizedValue”:”self-extinguishing”,”value”:”self-extinguishing”},{“name”:”Vibration Resistance”,”normalizedValue”:”0.35 mm 10-55 Hz)IEC 60068-2-6″,”value”:”0.35 mm 10-55 Hz)IEC 60068-2-6″},{“name”:”Power Consumption In Va”,”normalizedValue”:”1.1 VA 24 V || 4.8 VA 240 V”,”value”:”1.1 VA 24 V || 4.8 VA 240 V”},{“name”:”Line Rated Current”,”normalizedValue”:”5 A”,”value”:”5A”},{“name”:”Product Or Component Type”,”normalizedValue”:”multifunction relay”,”value”:”multifunction relay”},{“name”:”Minimum Switching Current”,”normalizedValue”:”100 mA”,”value”:”100 mA”},{“name”:”Voltage Drift”,”normalizedValue”:”+/- 0.2 %/V of the maximum setting value 48…240 V || +/- 1 %/V of the maximum setting value 24…48 V”,”value”:”+/- 0.2 %/V of the maximum setting value 48…240 V || +/- 1 %/V of the maximum setting value 24…48 V”},{“name”:”Immunity To Radioelectric Fields”,”normalizedValue”:”10 V 0.15…80 MHz)EN/IEC 61000-4-6 level 3″,”value”:”10 V 0.15…80 MHz)EN/IEC 61000-4-6 level 3″},{“name”:”Power Consumption In W”,”normalizedValue”:”0.5 W 24 V || 1.7 W 240 V”,”value”:”0.5 W 24 V || 1.7 W 240 V”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-20-50°C”,”value”:”-20-50°C”},{“name”:”Disturbance Radiated/Conducted”,”normalizedValue”:”class B 0.15…30 MHz EN 55022 (EN 55011 group 1)”,”value”:”class B 0.15…30 MHz EN 55022 (EN 55011 group 1)”},{“name”:”Component Name”,”normalizedValue”:”RE48A”,”value”:”RE48A”},{“name”:”Minimum Pulse Duration”,”normalizedValue”:”20 ms”,”value”:”20 ms”},{“name”:”Immunity To Microbreaks”,”normalizedValue”:”10 msec”,”value”:”10 ms”},{“name”:”Contacts Type And Composition”,”normalizedValue”:”2 C/O timed contacts, AgNi”,”value”:”2 C/O timed contacts, AgNi (cadmium free)”},{“name”:”Setting Accuracy Of Time Delay”,”normalizedValue”:”+/- 5 % of full scale 25°C IEC 61812-1″,”value”:”+/- 5 % of full scale 25°C IEC 61812-1″},{“name”:”Humidity Drift”,”normalizedValue”:”+/- 0.05 %/%RH of the maximum setting value IEC 61812-1″,”value”:”+/- 0.05 %/%RH of the maximum setting value IEC 61812-1″},{“name”:”Immunity To Voltage Dips”,”normalizedValue”:”30 % / 10 ms EN/IEC 61000-4-11 || 60 % / 100 ms EN/IEC 61000-4-11 || 95 % / 5 s EN/IEC 61000-4-11″,”value”:”30 % / 10 ms EN/IEC 61000-4-11 || 60 % / 100 ms EN/IEC 61000-4-11 || 95 % / 5 s EN/IEC 61000-4-11″},{“name”:”Product Front Plate Size”,”normalizedValue”:”48 x 48 mm”,”value”:”48 x 48 mm”},{“name”:”Mounting Support”,”normalizedValue”:”base mounted: socket || panel mounted: system supplied with the product”,”value”:”base mounted: socket || panel mounted: system supplied with the product”},{“name”:”Maximum Switching Voltage”,”normalizedValue”:”250 V AC/DC”,”value”:”250 V AC/DC”},{“name”:”Maximum Switching Current”,”normalizedValue”:”5 A”,”value”:”5A”},{“name”:”Time Delay Range”,”normalizedValue”:”0.5…30 s || 5…300 s || 0.2…12 min || 0.5…30 h || 2…120 s || 0.05…3 s || 0.2…12 s || 0.02…1.2 s || 2…120 min || 5…300 min || 0.5…30 min || 5…300 h || 2…120 h || 0.2…12 h”,”value”:”0.5…30 s || 5…300 s || 0.2…12 min || 0.5…30 h || 2…120 s || 0.05…3 s || 0.2…12 s || 0.02…1.2 s || 2…120 min || 5…300 min || 0.5…30 min || 5…300 h || 2…120 h || 0.2…12 h”},{“name”:”Voltage Range”,”normalizedValue”:”0.85…1.1 Us AC || 0.9…1.1 Us DC”,”value”:”0.85…1.1 Us AC || 0.9…1.1 Us DC”},{“name”:”Surge Withstand”,”normalizedValue”:”1 kV differential mode IEC 61000-4-5 level 3 || 2 kV common mode IEC 61000-4-5 level 3″,”value”:”1 kV differential mode IEC 61000-4-5 level 3 || 2 kV common mode IEC 61000-4-5 level 3″},{“name”:”On-Load Factor”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Pick Up Duration”,”normalizedValue”:”55 ms”,”value”:”55 ms”},{“name”:”Resistance To Electrostatic Discharge”,”normalizedValue”:”6 kV in contact EN/IEC 61000-4-2 level 3 || 8 kV in air EN/IEC 61000-4-2 level 3″,”value”:”6 kV in contact EN/IEC 61000-4-2 level 3 || 8 kV in air EN/IEC 61000-4-2 level 3″},{“name”:”Mechanical Durability”,”normalizedValue”:”30000000 cycles”,”value”:”30000000 cycles”},{“name”:”Repeat Accuracy”,”normalizedValue”:”+/- 0.2 % of the maximum setting value IEC 61812-1″,”value”:”+/- 0.2 % of the maximum setting value IEC 61812-1″},{“name”:”Relative Humidity”,”normalizedValue”:”93-93 %, without condensation IEC 60068-2-3″,”value”:”93-93 % without condensation IEC 60068-2-3″},{“name”:”Control Type”,”normalizedValue”:”selector switch front panel”,”value”:”selector switch front panel”},{“name”:”Marking”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”Breaking Capacity”,”normalizedValue”:”1250 VA”,”value”:”1250 VA”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP40 IEC 60529 housing) || IP50 IEC 60529 front face)”,”value”:”IP40 IEC 60529 housing) || IP50 IEC 60529 front face)”},{“name”:”Dielectric Strength”,”normalizedValue”:”1 kV 1 mA/1 minute IEC 61812-1″,”value”:”1 kV 1 mA/1 minute IEC 61812-1″},{“name”:”[Us] Rated Supply Voltage”,”normalizedValue”:”24…240 V AC/DC 50/60 Hz”,”value”:”24…240 V AC/DC 50/60 Hz”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-70°C”,”value”:”-40-70°C”},{“name”:”Electrical Durability”,”normalizedValue”:”100000 cycles”,”value”:”100000 cycles”},{“name”:”Local Signalling”,”normalizedValue”:”for output relay state 1 LED (yellow) || for flashing: relay energised timing in progress LED indicator (green) || for on steady: relay energised, no timing in progress LED indicator (green)”,”value”:”for output relay state 1 LED (yellow) || for flashing: relay energised timing in progress LED indicator (green) || for on steady: relay energised, no timing in progress LED indicator (green)”},{“name”:”Electrical Connection”,”normalizedValue”:”plug-in sub-“,”value”:”plug-in sub-base 11″},{“name”:”Resistance To Electromagnetic Fields”,”normalizedValue”:”10 V/m 26 MHz to 1 GHz IEC 61000-4-3 level 3″,”value”:”10 V/m 26 MHz to 1 GHz IEC 61000-4-3 level 3″},{“name”:”Protection Against Electric Shocks”,”normalizedValue”:”4 kV class III IEC 60664-1 || 4 kV class III IEC 61812-1″,”value”:”4 kV class III IEC 60664-1 || 4 kV class III IEC 61812-1″},{“name”:”Resistance To Fast Transients”,”normalizedValue”:”2 kV EN/IEC 61000-4-4 level 4 capacitive connecting clip) || 4 kV EN/IEC 61000-4-4 level 4 direct)”,”value”:”2 kV EN/IEC 61000-4-4 level 4 capacitive connecting clip) || 4 kV EN/IEC 61000-4-4 level 4 direct)”},{“name”:”Range of Product”,”normalizedValue”:”Harmony Relays”,”value”:”Harmony Timer Relays”},{“name”:”Number of Functions”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Indonesia”,”value”:”Indonesia”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.