Description
[{“name”:”Item”,”normalizedValue”:”Communication Cable”,”rank”:1,”value”:”Communication Cable”},{“name”:”Cable Length”,”normalizedValue”:”1,000 ft”,”rank”:2,”value”:”1,000 ft”},{“name”:”Number of Strands”,”normalizedValue”:”30″,”rank”:3,”value”:”30″},{“name”:”Conductor Gauge”,”normalizedValue”:”22 AWG”,”rank”:4,”value”:”22 AWG”},{“name”:”Fire Rating”,”normalizedValue”:”Commercial”,”rank”:5,”value”:”Commercial”},{“name”:”Jacket Color”,”normalizedValue”:”Natural”,”rank”:6,”value”:”Natural”},{“name”:”Jacket Material”,”normalizedValue”:”PVC”,”rank”:7,”value”:”PVC”},{“name”:”Number of Conductors”,”normalizedValue”:”4″,”rank”:8,”value”:”4″},{“name”:”Outside Diameter”,”normalizedValue”:”0.2 in”,”rank”:9,”value”:”0.2 in”},{“name”:”Solid/Stranded”,”normalizedValue”:”Stranded”,”rank”:10,”value”:”Stranded”},{“name”:”Shielding Material”,”normalizedValue”:”Foil”,”rank”:11,”value”:”Foil”},{“name”:”Maximum Voltage Rating”,”normalizedValue”:”300 V”,”rank”:12,”value”:”300 V”},{“name”:”NEC Article and Type”,”normalizedValue”:”800 CMP”,”rank”:13,”value”:”800 CMP”},{“name”:”Standards”,”normalizedValue”:”APAC Compliance-China RoHS Compliant II (GB/T 26572-2011), CMP, CPR Euroclass: Eca, EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), NEC Article 800 CMP, NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2, UKCA Mark”,”rank”:14,”value”:”APAC Compliance-China RoHS Compliant II (GB/T 26572-2011), CMP, CPR Euroclass: Eca, EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), NEC Article 800 CMP, NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2, UKCA Mark”},{“name”:”Length”,”normalizedValue”:”1,000 ft”,”value”:”1000 ft.”},{“name”:”Total Number of Conductors – Data Cable”,”normalizedValue”:”4″,”value”:”4 (2 Pair)”},{“name”:”Solid / Stranded”,”normalizedValue”:”Stranded”,”value”:”Stranded”},{“name”:”Shielded / Unshielded”,”normalizedValue”:”Shielded”,”value”:”Shielded”},{“name”:”Jacket Material – Wire and Cable”,”normalizedValue”:”PVC”,”value”:”PVC”},{“name”:”Spool Length”,”normalizedValue”:”1,000 ft”,”value”:”1,000 ft”},{“name”:”Package Type – Data Cable”,”normalizedValue”:”Reel in a Box”,”value”:”Reel in a Box”},{“name”:”Plenum / Riser Rated”,”normalizedValue”:”Plenum Rated”,”value”:”Plenum Rated”},{“name”:”Nominal Outside Dia.”,”normalizedValue”:”0.153 in”,”value”:”0.153 in”},{“name”:”Insulation Material”,”normalizedValue”:”FEP”,”value”:”FEP”},{“name”:”Suggested Voltage Rating – Data Cable”,”normalizedValue”:”300 V”,”value”:”300 V”},{“name”:”Application”,”normalizedValue”:”Alarm Systems, Audio Systems, Instrumentation Systems”,”value”:”Alarm Systems, Audio Systems, Instrumentation Systems”},{“name”:”Shielded”,”normalizedValue”:”Yes”,”value”:”Shielded”},{“name”:”Cable Sub-Category”,”normalizedValue”:”Multi-Conductor”,”value”:”Multi-Conductor”},{“name”:”Application – Communication Cable”,”normalizedValue”:”Audio Systems, Control Systems, Instrumentation Systems”,”value”:”Audio Systems, Control Systems, Instrumentation Systems”},{“name”:”Conductor Size”,”normalizedValue”:”22 AWG”,”value”:”22 AWG”},{“name”:”Conductor Size – Data Cable”,”normalizedValue”:”22 AWG”,”value”:”22 AWG”},{“name”:”Item – Data Cable”,”normalizedValue”:”Communication Cable”,”value”:”Communication Cable”},{“name”:”Temp. Range”,”normalizedValue”:”-4 to 194 deg F”,”value”:”-4 Degrees to 194 Degrees F”},{“name”:”Fire Rating – Data Cable”,”normalizedValue”:”Plenum”,”value”:”Plenum”},{“name”:”NEC Article”,”normalizedValue”:”800″,”value”:”800″},{“name”:”Impedance”,”normalizedValue”:”36 ohms (Nominal Impedance)”,”value”:”36 Ohm Nominal Impedance”},{“name”:”Package Type”,”normalizedValue”:”Reel in a Box”,”value”:”Reel in a Box”},{“name”:”Bend Radius”,”normalizedValue”:”1-1/2 in”,”value”:”1 1/2 in”},{“name”:”Maximum Current”,”normalizedValue”:”2.3 A”,”value”:”2.3 A”},{“name”:”Number of Pairs”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Maximum Capacitance”,”normalizedValue”:”43.0 pf/ft (Nominal Capacitance Conductor to Conductor); 75.0 pf/ft (Nominal Capacitance Conducotr to Other (Conductor + Shield))”,”value”:”43.0 pf/ft (Nominal Capacitance Conductor to Conductor); 75.0 pf/ft (Nominal Capacitance Conducotr to Other (Conductor + Shield))”},{“name”:”Product Type”,”normalizedValue”:”Communication Cable”,”value”:”Communication Cable”},{“name”:”Resistance Properties”,”normalizedValue”:”Flame/Fire Resistant”,”value”:”Flame/Fire Resistant”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”194 deg F”,”value”:”194 Degrees F”},{“name”:”Maximum Impedance”,”normalizedValue”:”36 ohms”,”value”:”36 ohm”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-4 deg F”,”value”:”-4 Degrees F”},{“name”:”Conductor Type”,”normalizedValue”:”Stranded Conductor”,”value”:”Stranded Conductor”},{“name”:”Jacketing Material”,”normalizedValue”:”Lspvc-Low Smoke Polyvinyl Chloride”,”value”:”Lspvc-Low Smoke Polyvinyl Chloride”},{“name”:”Material”,”normalizedValue”:”Tinned Copper”,”value”:”Tinned Copper”},{“name”:”Shield Type”,”normalizedValue”:”Mylar, Foil Shielded – Alum”,”value”:”Foil Shielded – Alum/Mylar”},{“name”:”Conductor Count”,”normalizedValue”:”2 Pairs”,”value”:”2 Pairs”},{“name”:”NEC Rating”,”normalizedValue”:”UL LISTED ART 800 PLENUM”,”value”:”UL LISTED ART 800 PLENUM”},{“name”:”Voltage Rating”,”normalizedValue”:”300 V AC”,”value”:”300 Volts AC”},{“name”:”CSA”,”normalizedValue”:”FT6 HORIZONTAL FLAME & SMOKE TEST”,”value”:”FT6 HORIZONTAL FLAME & SMOKE TEST”},{“name”:”Spec Nbr Ul Style”,”normalizedValue”:”UL LSTED WIRE MISC.”,”value”:”UL LSTED WIRE MISC.”},{“name”:”Screen/Shield”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Temperature Rating”,”normalizedValue”:”80 Degrees Centigrade”,”value”:”80 Degrees Centigrade”},{“name”:”Construction”,”normalizedValue”:”Indivl/Foil Side & Drain Out”,”value”:”Indivl/Foil Side & Drain Out”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.