Molded Case Circuit Breaker, QDL Series, 90A, 3 Pole, 240V AC, 25kA at 240V AC

$1055,99

Molded Case Circuit Breaker, 90 A Amps, AC Voltage Rating 240V AC, Max. AIR Rating 25kA at 240V AC, For Use With -, Series QD, High Amp Trip Setting 1,800 A, Low Amp Trip Setting 1,000 A, Circuit Breaker Type Standard, Number of Poles 3, DC Voltage Rating Not Rated, Terminal Connection Lug, Trip Type Thermal Magnetic, Phase Three, Instantaneous Trip Fixed, Phase Connection ABC, Frame Size 250A/QD, Circuit Breaker Mounting Style Free Standing, Height 6.47 in, Width 4.5 in, Depth 3.93 in

9999 in stock

SKU: GRG2917975 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Molded Case Circuit Breaker”,”rank”:2,”value”:”Molded Case Circuit Breaker”},{“name”:”Series”,”normalizedValue”:”QDL”,”rank”:3,”value”:”QDL”},{“name”:”Amps”,”normalizedValue”:”90A”,”rank”:4,”value”:”90A”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”rank”:5,”value”:”3″},{“name”:”AC Voltage Rating”,”normalizedValue”:”240V AC”,”rank”:6,”value”:”240V AC”},{“name”:”Circuit Breaker Type”,”normalizedValue”:”Standard”,”rank”:7,”value”:”Standard”},{“name”:”Phase”,”normalizedValue”:”3″,”rank”:8,”value”:”3″},{“name”:”Circuit Breaker Actuator”,”normalizedValue”:”Toggle”,”rank”:9,”value”:”Toggle”},{“name”:”Circuit Breaker Mounting Style”,”normalizedValue”:”Unit Mount”,”rank”:10,”value”:”Unit Mount”},{“name”:”Max. AIR Rating”,”normalizedValue”:”25kA at 240V AC”,”rank”:11,”value”:”25kA at 240V AC”},{“name”:”Trip Type”,”normalizedValue”:”Thermal Magnetic”,”rank”:12,”value”:”Thermal Magnetic”},{“name”:”Instantaneous Trip”,”normalizedValue”:”Fixed”,”rank”:13,”value”:”Fixed”},{“name”:”Terminal Connection”,”normalizedValue”:”Line, Load Lug”,”rank”:14,”value”:”Line/Load Lug”},{“name”:”Phase Connection”,”normalizedValue”:”ABC”,”rank”:15,”value”:”ABC”},{“name”:”Frame Size”,”normalizedValue”:”250A, QD”,”rank”:16,”value”:”250A/QD”},{“name”:”Width”,”normalizedValue”:”4-1/2 in”,”rank”:17,”value”:”4.5 in”},{“name”:”Depth”,”normalizedValue”:”3.93 in”,”rank”:18,”value”:”3.93 in”},{“name”:”Height”,”normalizedValue”:”6.47 in”,”rank”:19,”value”:”6.47 in”},{“name”:”DC Voltage Rating”,”normalizedValue”:”Not Rated”,”rank”:20,”value”:”Not Rated”},{“name”:”Min. Wire Size”,”normalizedValue”:”4 AWG”,”value”:”4 AWG”},{“name”:”Max. Wire Size”,”normalizedValue”:”300 MCM”,”value”:”300 MCM”},{“name”:”Low Amp Trip Setting”,”normalizedValue”:”1,000 A”,”value”:”1,000 A”},{“name”:”Standards”,”normalizedValue”:”CSA, IEC, UL Listed”,”value”:”CSA, IEC, UL Listed”},{“name”:”High Amp Trip Setting”,”normalizedValue”:”1,800 A”,”value”:”1,800 A”},{“name”:”Application”,”normalizedValue”:”HACR rated Applications; Distribution”,”value”:”HACR rated Applications; Distribution”},{“name”:”Interrupt Rating”,”normalizedValue”:”25 kA at 120/208/240V AC”,”value”:”25 kA at 120/208/240V AC”},{“name”:”Features”,”normalizedValue”:”Mercury Free; PVC Free”,”value”:”Mercury Free; PVC Free”},{“name”:”Max. Operating Temp.”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Mounting”,”normalizedValue”:”Free Standing”,”value”:”Free Standing”},{“name”:”Control Type”,”normalizedValue”:”Operating handle”,”value”:”Operating handle”},{“name”:”Product Name”,”normalizedValue”:”PowerPact Q”,”value”:”PowerPact Q”},{“name”:”Local Signalling”,”normalizedValue”:”1 trip indicator green)”,”value”:”1 trip indicator green)”},{“name”:”Device Application”,”normalizedValue”:”Distribution”,”value”:”Distribution”},{“name”:”Continuous Current Rating”,”normalizedValue”:”0.8″,”value”:”0.8″},{“name”:”Utilisation Category”,”normalizedValue”:”Category A”,”value”:”Category A”},{“name”:”Magnetic Tripping Current”,”normalizedValue”:”1,800 A”,”value”:”1800 A”},{“name”:”Breaking Capacity Code”,”normalizedValue”:”D”,”value”:”D”},{“name”:”Breaking Capacity”,”normalizedValue”:”25 kA 120/208 V AC 50/60 Hz UL; 25 kA 240 V AC 50/60 Hz UL”,”value”:”25 kA 120/208 V AC 50/60 Hz UL; 25 kA 240 V AC 50/60 Hz UL”},{“name”:”Circuit Breaker Application”,”normalizedValue”:”HACR rated”,”value”:”HACR rated”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”104 to 158°F (40 to 70°C)”,”value”:”104 to 158°F (40 to 70°C)”},{“name”:”Product Certifications”,”normalizedValue”:”CSA, UL, NOM”,”value”:”UL; CSA; NOM”},{“name”:”Magnetic Hold Current”,”normalizedValue”:”1,000 A”,”value”:”1000 A”},{“name”:”Mechanical Durability”,”normalizedValue”:”1000 cycles loaded; 5000 cycles no load”,”value”:”1000 cycles loaded; 5000 cycles no load”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”240 V AC 50/60 Hz UL”,”value”:”240 V AC 50/60 Hz UL”},{“name”:”Network Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Power Wire Stripping Length”,”normalizedValue”:”0.87 in”,”value”:”0.87 in (22 mm)”},{“name”:”Tightening Torque”,”normalizedValue”:”247.82 lbf.in (28 N.m) 0.04 to 0.23 in² (25 to 150 mm²) (AWG 4 to 300 kcmil)”,”value”:”247.82 lbf.in (28 N.m) 0.04 to 0.23 in² (25 to 150 mm²) (AWG 4 to 300 kcmil)”},{“name”:”Rated Impulse Withstand Voltage”,”normalizedValue”:”8 kV UL”,”value”:”8 kV UL”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Molded Case Circuit Breaker, QDL Series, 90A, 3 Pole, 240V AC, 25kA at 240V AC”