Description
[{“name”:”Item”,”normalizedValue”:”Molded Case Circuit Breaker”,”rank”:2,”value”:”Molded Case Circuit Breaker”},{“name”:”Series”,”normalizedValue”:”QDL”,”rank”:3,”value”:”QDL”},{“name”:”Amps”,”normalizedValue”:”70A”,”rank”:4,”value”:”70A”},{“name”:”Number of Poles”,”normalizedValue”:”2″,”rank”:5,”value”:”2″},{“name”:”AC Voltage Rating”,”normalizedValue”:”240V AC”,”rank”:6,”value”:”240V AC”},{“name”:”Circuit Breaker Type”,”normalizedValue”:”Standard”,”rank”:7,”value”:”Standard”},{“name”:”Phase”,”normalizedValue”:”1″,”rank”:8,”value”:”1″},{“name”:”Circuit Breaker Actuator”,”normalizedValue”:”Toggle”,”rank”:9,”value”:”Toggle”},{“name”:”Circuit Breaker Mounting Style”,”normalizedValue”:”Unit Mount”,”rank”:10,”value”:”Unit Mount”},{“name”:”Max. AIR Rating”,”normalizedValue”:”25kA at 240V AC”,”rank”:11,”value”:”25kA at 240V AC”},{“name”:”Trip Type”,”normalizedValue”:”Thermal Magnetic”,”rank”:12,”value”:”Thermal Magnetic”},{“name”:”Instantaneous Trip”,”normalizedValue”:”Fixed”,”rank”:13,”value”:”Fixed”},{“name”:”Terminal Connection”,”normalizedValue”:”Line, Load Lug”,”rank”:14,”value”:”Line/Load Lug”},{“name”:”Phase Connection”,”normalizedValue”:””,”rank”:15,”value”:”Not Applicable”},{“name”:”Frame Size”,”normalizedValue”:”250A, QD”,”rank”:16,”value”:”250A/QD”},{“name”:”Width”,”normalizedValue”:”3 in”,”rank”:17,”value”:”3 in”},{“name”:”Depth”,”normalizedValue”:”3.93 in”,”rank”:18,”value”:”3.93 in”},{“name”:”Height”,”normalizedValue”:”6.47 in”,”rank”:19,”value”:”6.47 in”},{“name”:”DC Voltage Rating”,”normalizedValue”:”Not Rated”,”rank”:20,”value”:”Not Rated”},{“name”:”Standards”,”normalizedValue”:”CSA, IEC, UL Listed”,”value”:”CSA, IEC, UL Listed”},{“name”:”Min. Wire Size”,”normalizedValue”:”4 AWG”,”value”:”4 AWG”},{“name”:”Max. Wire Size”,”normalizedValue”:”300 MCM”,”value”:”300 MCM”},{“name”:”High Amp Trip Setting”,”normalizedValue”:”1,800 A”,”value”:”1,800 A”},{“name”:”Low Amp Trip Setting”,”normalizedValue”:”1,000 A”,”value”:”1,000 A”},{“name”:”Features”,”normalizedValue”:”Mercury Free; PVC Free”,”value”:”Mercury Free; PVC Free”},{“name”:”Application”,”normalizedValue”:”HACR rated Applications; Distribution”,”value”:”HACR rated Applications; Distribution”},{“name”:”Interrupt Rating”,”normalizedValue”:”25 kA at 120/208/240V AC”,”value”:”25 kA at 120/208/240V AC”},{“name”:”Max. Operating Temp.”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Mounting”,”normalizedValue”:”Free Standing”,”value”:”Free Standing”},{“name”:”Utilisation Category”,”normalizedValue”:”Category A”,”value”:”Category A”},{“name”:”Power Wire Stripping Length”,”normalizedValue”:”0.87 in”,”value”:”0.87 in (22 mm)”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”104 to 158°F (40 to 70°C)”,”value”:”104 to 158°F (40 to 70°C)”},{“name”:”Tightening Torque”,”normalizedValue”:”247.82 lbf.in (28 N.m) 0.04 to 0.23 in² (25 to 150 mm²) (AWG 4 to 300 kcmil)”,”value”:”247.82 lbf.in (28 N.m) 0.04 to 0.23 in² (25 to 150 mm²) (AWG 4 to 300 kcmil)”},{“name”:”Product Certifications”,”normalizedValue”:”CSA, UL, NOM”,”value”:”UL; CSA; NOM”},{“name”:”Continuous Current Rating”,”normalizedValue”:”0.8″,”value”:”0.8″},{“name”:”Local Signalling”,”normalizedValue”:”1 trip indicator green)”,”value”:”1 trip indicator green)”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”240 V AC 50/60 Hz UL”,”value”:”240 V AC 50/60 Hz UL”},{“name”:”Circuit Breaker Application”,”normalizedValue”:”HACR rated”,”value”:”HACR rated”},{“name”:”Device Application”,”normalizedValue”:”Distribution”,”value”:”Distribution”},{“name”:”Rated Impulse Withstand Voltage”,”normalizedValue”:”8 kV UL”,”value”:”8 kV UL”},{“name”:”Mechanical Durability”,”normalizedValue”:”1000 cycles loaded; 5000 cycles no load”,”value”:”1000 cycles loaded; 5000 cycles no load”},{“name”:”Control Type”,”normalizedValue”:”Operating handle”,”value”:”Operating handle”},{“name”:”Product Name”,”normalizedValue”:”PowerPact Q”,”value”:”PowerPact Q”},{“name”:”Network Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Breaking Capacity”,”normalizedValue”:”25 kA 120/208 V AC 50/60 Hz UL; 25 kA 240 V AC 50/60 Hz UL”,”value”:”25 kA 120/208 V AC 50/60 Hz UL; 25 kA 240 V AC 50/60 Hz UL”},{“name”:”Magnetic Hold Current”,”normalizedValue”:”1,000 A”,”value”:”1000 A”},{“name”:”Magnetic Tripping Current”,”normalizedValue”:”1,800 A”,”value”:”1800 A”},{“name”:”Breaking Capacity Code”,”normalizedValue”:”D”,”value”:”D”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.