Molded Case Circuit Breaker, QDL Series, 110A, 2 Pole, 240V AC, 25kA at 240V AC

$811,99

Molded Case Circuit Breaker, 110 A Amps, AC Voltage Rating 240V AC, Max. AIR Rating 25kA at 240V AC, For Use With -, Series QD, High Amp Trip Setting 2,400 A, Low Amp Trip Setting 1,200 A, Circuit Breaker Type Standard, Number of Poles 2, DC Voltage Rating Not Rated, Terminal Connection Lug, Trip Type Thermal Magnetic, Phase Single, Instantaneous Trip Fixed, Phase Connection Not Applicable, Frame Size 250A/QD, Circuit Breaker Mounting Style Free Standing, Height 6.47 in, Width 4.5 in

9999 in stock

SKU: GRG0323915 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Molded Case Circuit Breaker”,”rank”:2,”value”:”Molded Case Circuit Breaker”},{“name”:”Series”,”normalizedValue”:”QDL”,”rank”:3,”value”:”QDL”},{“name”:”Amps”,”normalizedValue”:”110A”,”rank”:4,”value”:”110A”},{“name”:”Number of Poles”,”normalizedValue”:”2″,”rank”:5,”value”:”2″},{“name”:”AC Voltage Rating”,”normalizedValue”:”240V AC”,”rank”:6,”value”:”240V AC”},{“name”:”Circuit Breaker Type”,”normalizedValue”:”Standard”,”rank”:7,”value”:”Standard”},{“name”:”Phase”,”normalizedValue”:”1″,”rank”:8,”value”:”1″},{“name”:”Circuit Breaker Actuator”,”normalizedValue”:”Toggle”,”rank”:9,”value”:”Toggle”},{“name”:”Circuit Breaker Mounting Style”,”normalizedValue”:”Unit Mount”,”rank”:10,”value”:”Unit Mount”},{“name”:”Max. AIR Rating”,”normalizedValue”:”25kA at 240V AC”,”rank”:11,”value”:”25kA at 240V AC”},{“name”:”Trip Type”,”normalizedValue”:”Thermal Magnetic”,”rank”:12,”value”:”Thermal Magnetic”},{“name”:”Instantaneous Trip”,”normalizedValue”:”Fixed”,”rank”:13,”value”:”Fixed”},{“name”:”Terminal Connection”,”normalizedValue”:”Line, Load Lug”,”rank”:14,”value”:”Line/Load Lug”},{“name”:”Phase Connection”,”normalizedValue”:””,”rank”:15,”value”:”Not Applicable”},{“name”:”Frame Size”,”normalizedValue”:”250A, QD”,”rank”:16,”value”:”250A/QD”},{“name”:”Width”,”normalizedValue”:”3 in”,”rank”:17,”value”:”3 in”},{“name”:”Depth”,”normalizedValue”:”3.93 in”,”rank”:18,”value”:”3.93 in”},{“name”:”Height”,”normalizedValue”:”6.47 in”,”rank”:19,”value”:”6.47 in”},{“name”:”DC Voltage Rating”,”normalizedValue”:”Not Rated”,”rank”:20,”value”:”Not Rated”},{“name”:”Standards”,”normalizedValue”:”CSA, IEC, UL Listed”,”value”:”CSA, IEC, UL Listed”},{“name”:”Low Amp Trip Setting”,”normalizedValue”:”1,200 A”,”value”:”1,200 A”},{“name”:”Min. Wire Size”,”normalizedValue”:”4 AWG”,”value”:”4 AWG”},{“name”:”Max. Wire Size”,”normalizedValue”:”300 MCM”,”value”:”300 MCM”},{“name”:”High Amp Trip Setting”,”normalizedValue”:”2,400 A”,”value”:”2,400 A”},{“name”:”Features”,”normalizedValue”:”Mercury Free; PVC Free”,”value”:”Mercury Free; PVC Free”},{“name”:”Interrupt Rating”,”normalizedValue”:”25 kA at 120/208/240V AC”,”value”:”25 kA at 120/208/240V AC”},{“name”:”Application”,”normalizedValue”:”HACR rated Applications; Distribution”,”value”:”HACR rated Applications; Distribution”},{“name”:”Max. Operating Temp.”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Mounting”,”normalizedValue”:”Free Standing”,”value”:”Free Standing”},{“name”:”Tightening Torque”,”normalizedValue”:”247.82 lbf.in (28 N.m) 0.04 to 0.23 in² (25 to 150 mm²) (AWG 4 to 300 kcmil)”,”value”:”247.82 lbf.in (28 N.m) 0.04 to 0.23 in² (25 to 150 mm²) (AWG 4 to 300 kcmil)”},{“name”:”Magnetic Tripping Current”,”normalizedValue”:”2,400 A”,”value”:”2400 A”},{“name”:”Power Wire Stripping Length”,”normalizedValue”:”0.87 in”,”value”:”0.87 in (22 mm)”},{“name”:”Device Application”,”normalizedValue”:”Distribution”,”value”:”Distribution”},{“name”:”Magnetic Hold Current”,”normalizedValue”:”1,200 A”,”value”:”1200 A”},{“name”:”Local Signalling”,”normalizedValue”:”1 trip indicator green)”,”value”:”1 trip indicator green)”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”240 V AC 50/60 Hz UL”,”value”:”240 V AC 50/60 Hz UL”},{“name”:”Mechanical Durability”,”normalizedValue”:”1000 cycles loaded; 5000 cycles no load”,”value”:”1000 cycles loaded; 5000 cycles no load”},{“name”:”Circuit Breaker Application”,”normalizedValue”:”HACR rated”,”value”:”HACR rated”},{“name”:”Breaking Capacity Code”,”normalizedValue”:”D”,”value”:”D”},{“name”:”Network Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Breaking Capacity”,”normalizedValue”:”25 kA 120/208 V AC 50/60 Hz UL; 25 kA 240 V AC 50/60 Hz UL”,”value”:”25 kA 120/208 V AC 50/60 Hz UL; 25 kA 240 V AC 50/60 Hz UL”},{“name”:”Utilisation Category”,”normalizedValue”:”Category A”,”value”:”Category A”},{“name”:”Product Certifications”,”normalizedValue”:”CSA, UL, NOM”,”value”:”UL; CSA; NOM”},{“name”:”Rated Impulse Withstand Voltage”,”normalizedValue”:”8 kV UL”,”value”:”8 kV UL”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”104 to 158°F (40 to 70°C)”,”value”:”104 to 158°F (40 to 70°C)”},{“name”:”Product Name”,”normalizedValue”:”PowerPact Q”,”value”:”PowerPact Q”},{“name”:”Continuous Current Rating”,”normalizedValue”:”0.8″,”value”:”0.8″},{“name”:”Control Type”,”normalizedValue”:”Operating handle”,”value”:”Operating handle”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Molded Case Circuit Breaker, QDL Series, 110A, 2 Pole, 240V AC, 25kA at 240V AC”