Molded Case Circuit Breaker, QDA Series, 100A, 3 Pole, 240V AC, 25kA at 240V AC

$1691,99

Molded Case Circuit Breaker, 100 A Amps, AC Voltage Rating 240V AC, Max. AIR Rating 25kA at 240V AC, For Use With I Line Panelboards, Series QD, High Amp Trip Setting 2,400 A, Low Amp Trip Setting 1,200 A, Circuit Breaker Type Standard, Number of Poles 3, DC Voltage Rating Not Rated, Terminal Connection Lug, Trip Type Thermal Magnetic, Phase Three, Instantaneous Trip Fixed, Phase Connection ABC, Frame Size 250A/QD, Circuit Breaker Mounting Style I-Line, Height 6.47 in, Width 4.5 in

Out of stock

SKU: GRG2256177 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Molded Case Circuit Breaker”,”rank”:2,”value”:”Molded Case Circuit Breaker”},{“name”:”Series”,”normalizedValue”:”QDA”,”rank”:3,”value”:”QDA”},{“name”:”Amps”,”normalizedValue”:”100A”,”rank”:4,”value”:”100A”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”rank”:5,”value”:”3″},{“name”:”AC Voltage Rating”,”normalizedValue”:”240V AC”,”rank”:6,”value”:”240V AC”},{“name”:”Circuit Breaker Type”,”normalizedValue”:”Standard”,”rank”:7,”value”:”Standard”},{“name”:”Phase”,”normalizedValue”:”3″,”rank”:8,”value”:”3″},{“name”:”Circuit Breaker Actuator”,”normalizedValue”:”Toggle”,”rank”:9,”value”:”Toggle”},{“name”:”Circuit Breaker Mounting Style”,”normalizedValue”:”I-Line”,”rank”:10,”value”:”I-Line”},{“name”:”Max. AIR Rating”,”normalizedValue”:”25kA at 240V AC”,”rank”:11,”value”:”25kA at 240V AC”},{“name”:”Trip Type”,”normalizedValue”:”Thermal Magnetic”,”rank”:12,”value”:”Thermal Magnetic”},{“name”:”Instantaneous Trip”,”normalizedValue”:”Fixed”,”rank”:13,”value”:”Fixed”},{“name”:”Terminal Connection”,”normalizedValue”:”Lug, I-Line”,”rank”:14,”value”:”I-Line, Lug”},{“name”:”Phase Connection”,”normalizedValue”:”ABC”,”rank”:15,”value”:”ABC”},{“name”:”Frame Size”,”normalizedValue”:”250A, QD”,”rank”:16,”value”:”250A/QD”},{“name”:”Width”,”normalizedValue”:”4-1/2 in”,”rank”:17,”value”:”4.5 in”},{“name”:”Depth”,”normalizedValue”:”3.93 in”,”rank”:18,”value”:”3.93 in”},{“name”:”Height”,”normalizedValue”:”6.47 in”,”rank”:19,”value”:”6.47 in”},{“name”:”DC Voltage Rating”,”normalizedValue”:”Not Rated”,”rank”:20,”value”:”Not Rated”},{“name”:”For Use With”,”normalizedValue”:”I Line Panelboards”,”value”:”I Line Panelboards”},{“name”:”Min. Wire Size”,”normalizedValue”:”4 AWG”,”value”:”4 AWG”},{“name”:”High Amp Trip Setting”,”normalizedValue”:”2,400 A”,”value”:”2,400 A”},{“name”:”Max. Wire Size”,”normalizedValue”:”300 MCM”,”value”:”300 MCM”},{“name”:”Standards”,”normalizedValue”:”CSA, IEC, UL Listed”,”value”:”CSA, IEC, UL Listed”},{“name”:”Low Amp Trip Setting”,”normalizedValue”:”1,200 A”,”value”:”1,200 A”},{“name”:”Application”,”normalizedValue”:”HACR rated Applications; Distribution”,”value”:”HACR rated Applications; Distribution”},{“name”:”Interrupt Rating”,”normalizedValue”:”25 kA at 120/208/240V AC”,”value”:”25 kA at 120/208/240V AC”},{“name”:”Features”,”normalizedValue”:”Mercury Free; PVC Free”,”value”:”Mercury Free; PVC Free”},{“name”:”Mounting”,”normalizedValue”:”Plug In Panelboard”,”value”:”Plug In Panelboard”},{“name”:”Magnetic Hold Current”,”normalizedValue”:”1,200 A”,”value”:”1200 A”},{“name”:”Mechanical Durability”,”normalizedValue”:”1000 cycles loaded; 5000 cycles no load”,”value”:”1000 cycles loaded; 5000 cycles no load”},{“name”:”Product Name”,”normalizedValue”:”PowerPact Q”,”value”:”PowerPact Q”},{“name”:”Rated Impulse Withstand Voltage”,”normalizedValue”:”8 kV UL”,”value”:”8 kV UL”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”240 V AC 50/60 Hz UL”,”value”:”240 V AC 50/60 Hz UL”},{“name”:”Breaking Capacity”,”normalizedValue”:”25 kA 120/208 V AC 50/60 Hz UL; 25 kA 240 V AC 50/60 Hz UL”,”value”:”25 kA 120/208 V AC 50/60 Hz UL; 25 kA 240 V AC 50/60 Hz UL”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”104 to 158°F (40 to 70°C)”,”value”:”104 to 158°F (40 to 70°C)”},{“name”:”Utilisation Category”,”normalizedValue”:”Category A”,”value”:”Category A”},{“name”:”Local Signalling”,”normalizedValue”:”1 trip indicator green)”,”value”:”1 trip indicator green)”},{“name”:”Power Wire Stripping Length”,”normalizedValue”:”0.87 in”,”value”:”0.87 in (22 mm)”},{“name”:”Device Application”,”normalizedValue”:”Distribution”,”value”:”Distribution”},{“name”:”Breaking Capacity Code”,”normalizedValue”:”D”,”value”:”D”},{“name”:”Product Certifications”,”normalizedValue”:”CSA, UL, NOM”,”value”:”UL; CSA; NOM”},{“name”:”Tightening Torque”,”normalizedValue”:”247.82 lbf.in (28 N.m) 0.04 to 0.23 in² (25 to 150 mm²) (AWG 4 to 300 kcmil)”,”value”:”247.82 lbf.in (28 N.m) 0.04 to 0.23 in² (25 to 150 mm²) (AWG 4 to 300 kcmil)”},{“name”:”Continuous Current Rating”,”normalizedValue”:”0.8″,”value”:”0.8″},{“name”:”Control Type”,”normalizedValue”:”Operating handle”,”value”:”Operating handle”},{“name”:”Network Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Circuit Breaker Application”,”normalizedValue”:”HACR rated”,”value”:”HACR rated”},{“name”:”Mounting Height”,”normalizedValue”:”4-1/2 in”,”value”:”4.5 in (114.30 mm)”},{“name”:”Magnetic Tripping Current”,”normalizedValue”:”2,400 A”,”value”:”2400 A”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Molded Case Circuit Breaker, QDA Series, 100A, 3 Pole, 240V AC, 25kA at 240V AC”