Description
[{“name”:”Item”,”normalizedValue”:”Molded Case Circuit Breaker”,”rank”:2,”value”:”Molded Case Circuit Breaker”},{“name”:”Series”,”normalizedValue”:”POWERPACT”,”rank”:3,”value”:”POWERPACT”},{“name”:”Amps”,”normalizedValue”:”90A”,”rank”:4,”value”:”90A”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”rank”:5,”value”:”3″},{“name”:”AC Voltage Rating”,”normalizedValue”:”600V AC”,”rank”:6,”value”:”600V AC”},{“name”:”Circuit Breaker Type”,”normalizedValue”:”Standard”,”rank”:7,”value”:”Standard”},{“name”:”Phase”,”normalizedValue”:”3″,”rank”:8,”value”:”3″},{“name”:”Circuit Breaker Actuator”,”normalizedValue”:”I-Line”,”rank”:9,”value”:”I-Line”},{“name”:”Circuit Breaker Mounting Style”,”normalizedValue”:”Plug In”,”rank”:10,”value”:”Plug In”},{“name”:”Max. AIR Rating”,”normalizedValue”:”65kA at 240V AC”,”rank”:11,”value”:”65kA at 240V AC”},{“name”:”Trip Type”,”normalizedValue”:”Thermal Magnetic”,”rank”:12,”value”:”Thermal Magnetic”},{“name”:”Instantaneous Trip”,”normalizedValue”:”Fixed”,”rank”:13,”value”:”Fixed”},{“name”:”Terminal Connection”,”normalizedValue”:”Lugs”,”rank”:14,”value”:”Lugs”},{“name”:”Phase Connection”,”normalizedValue”:”ABC”,”rank”:15,”value”:”ABC”},{“name”:”Frame Size”,”normalizedValue”:”150A/HG”,”rank”:16,”value”:”150A/HG”},{“name”:”Width”,”normalizedValue”:”4.12 in”,”rank”:17,”value”:”4.12 in”},{“name”:”Depth”,”normalizedValue”:”4.36 in”,”rank”:18,”value”:”4.36 in”},{“name”:”Height”,”normalizedValue”:”6.4 in”,”rank”:19,”value”:”6.40 in”},{“name”:”DC Voltage Rating”,”normalizedValue”:”250/500V DC”,”rank”:20,”value”:”250/500V DC”},{“name”:”Low Amp Trip Setting”,”normalizedValue”:”800 A”,”value”:”800 A”},{“name”:”Max. Wire Size”,”normalizedValue”:”3 AWG”,”value”:”3 AWG”},{“name”:”High Amp Trip Setting”,”normalizedValue”:”1,450 A”,”value”:”1,450 A”},{“name”:”Min. Wire Size”,”normalizedValue”:”14 AWG”,”value”:”14 AWG”},{“name”:”Standards”,”normalizedValue”:”CE, CSA, IEC, UL listed”,”value”:”CE, CSA, IEC, UL listed”},{“name”:”For Use With”,”normalizedValue”:”I Line Panelboards”,”value”:”I Line Panelboards”},{“name”:”Application”,”normalizedValue”:”HACR rated Applications; Distribution”,”value”:”HACR rated Applications; Distribution”},{“name”:”Features”,”normalizedValue”:”Mercury Free; PVC Free”,”value”:”Mercury Free; PVC Free”},{“name”:”Interrupt Rating”,”normalizedValue”:”65 kA at 220/240V AC, 35 kA at 380/440/415/480V AC, 18 kA at 500/525/600V AC, 20 kA at 250/500V DC”,”value”:”65 kA at 220/240V AC, 35 kA at 380/440/415/480V AC, 18 kA at 500/525/600V AC, 20 kA at 250/500V DC”},{“name”:”Color”,”normalizedValue”:”Black”,”value”:”Black”},{“name”:”Product Certifications”,”normalizedValue”:”CSA, UL, NOM”,”value”:”UL; CSA; NOM”},{“name”:”Terminal Identifier”,”normalizedValue”:”AL150HD”,”value”:”AL150HD”},{“name”:”Rated Impulse Withstand Voltage”,”normalizedValue”:”8 kV IEC 60947-2″,”value”:”8 kV IEC 60947-2″},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”28 to 158°F (-2 to 70°C)”,”value”:”28 to 158°F (-2 to 70°C)”},{“name”:”Breaking Capacity”,”normalizedValue”:”65 kA 240 V AC 50/60 Hz UL 489; 35 kA 480 V AC 50/60 Hz UL 489; 18 kA 600 V AC 50/60 Hz UL 489; 20 kA 250 V DC UL 489; 20 kA 500 V DC UL 489″,”value”:”65 kA 240 V AC 50/60 Hz UL 489; 35 kA 480 V AC 50/60 Hz UL 489; 18 kA 600 V AC 50/60 Hz UL 489; 20 kA 250 V DC UL 489; 20 kA 500 V DC UL 489″},{“name”:”Power Wire Stripping Length”,”normalizedValue”:”0.63 in”,”value”:”0.63 in (16 mm)”},{“name”:”Rated Service Breaking Capacity”,”normalizedValue”:”65 kA 220/240 V AC 50/60 Hz IEC 60947-2; 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2; 18 kA 500/525 V AC 50/60 Hz IEC 60947-2; 20 kA 250 V DC IEC 60947-2; 20 kA 500 V DC IEC 60947-2″,”value”:”65 kA 220/240 V AC 50/60 Hz IEC 60947-2; 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2; 18 kA 500/525 V AC 50/60 Hz IEC 60947-2; 20 kA 250 V DC IEC 60947-2; 20 kA 500 V DC IEC 60947-2″},{“name”:”Tightening Torque”,”normalizedValue”:”44.25 lbf.in (5 N.m) 0.00 to 0.01 in² (2.5 to 6 mm²) (AWG 14 to AWG 10); 123.91 lbf.in (14 N.m) 0.02 to 0.15 in² (10 to 95 mm²) (AWG 8 to AWG 3/0)”,”value”:”44.25 lbf.in (5 N.m) 0.00 to 0.01 in² (2.5 to 6 mm²) (AWG 14 to AWG 10); 123.91 lbf.in (14 N.m) 0.02 to 0.15 in² (10 to 95 mm²) (AWG 8 to AWG 3/0)”},{“name”:”Protected Poles Description”,”normalizedValue”:”3t”,”value”:”3t”},{“name”:”Mounting Height”,”normalizedValue”:”4-1/2 in”,”value”:”4.5 in (114.30 mm)”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”690 V AC 50/60 Hz IEC 60947-3″,”value”:”690 V AC 50/60 Hz IEC 60947-3″},{“name”:”Pollution Degree”,”normalizedValue”:”3 IEC 60947-1″,”value”:”3 IEC 60947-1″},{“name”:”Continuous Current Rating”,”normalizedValue”:”0.8″,”value”:”0.8″},{“name”:”Quality Labels”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-58 to 185°F”,”value”:”-58 to 185°F (-50 to 85°C)”},{“name”:”Device Application”,”normalizedValue”:”Distribution”,”value”:”Distribution”},{“name”:”Suitability For Isolation”,”normalizedValue”:”Yes IEC 60947-2″,”value”:”Yes IEC 60947-2″},{“name”:”Operating Altitude”,”normalizedValue”:”Less than 6561.68 ft (2000 m) without derating; 5000 m with derating”,”value”:”Less than 6561.68 ft (2000 m) without derating; 5000 m with derating”},{“name”:”Local Signalling”,”normalizedValue”:”Switched off (OFF) 1 trip indicator green)”,”value”:”Switched off (OFF) 1 trip indicator green)”},{“name”:”IP Degree Of Protection”,”normalizedValue”:”Front cover IP40 IEC 60529″,”value”:”Front cover IP40 IEC 60529″},{“name”:”Communication Interface”,”normalizedValue”:”Modbus, Ethernet”,”value”:”Modbus; Ethernet”},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”750 V IEC 60947-2″,”value”:”750 V IEC 60947-2″},{“name”:”Number Of Slots”,”normalizedValue”:”2 auxiliary switch OF plug-in); 1 alarm switch SD plug-in); 1 overcurrent trip switch SDE plug-in); 1 voltage release MN or MX plug-in)”,”value”:”2 auxiliary switch OF plug-in); 1 alarm switch SD plug-in); 1 overcurrent trip switch SDE plug-in); 1 voltage release MN or MX plug-in)”},{“name”:”Magnetic Tripping Current”,”normalizedValue”:”1,450 A”,”value”:”1450 A”},{“name”:”Circuit Breaker Application”,”normalizedValue”:”HACR rated”,”value”:”HACR rated”},{“name”:”Breaking Capacity Code”,”normalizedValue”:”G”,”value”:”G”},{“name”:”Network Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”AWG Gauge”,”normalizedValue”:”AWG 14 to AWG 3/0 aluminium/copper terminal”,”value”:”AWG 14 to AWG 3/0 aluminium/copper terminal”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.