Molded Case Circuit Breaker, POWERPACT Series, 175A, 2 Pole, 600V AC, 65kA at 240V AC

$2968,99

Molded Case Circuit Breaker, 175 A Amps, AC Voltage Rating 600V AC, Max. AIR Rating 65kA at 240V AC, For Use With I Line Panelboards, Series JG, High Amp Trip Setting 1,750 A, Low Amp Trip Setting 875 A, Circuit Breaker Type Standard, Number of Poles 2, DC Voltage Rating 250V DC, Terminal Connection Lug, Trip Type Thermal Magnetic, Phase Single, Instantaneous Trip Adjustable, Phase Connection AB, Frame Size 250A/JG, Circuit Breaker Mounting Style Plug In Panelboard, Height 7.5 in, Width 4.1 in

9999 in stock

SKU: GRG2988632 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Molded Case Circuit Breaker”,”rank”:2,”value”:”Molded Case Circuit Breaker”},{“name”:”Series”,”normalizedValue”:”POWERPACT”,”rank”:3,”value”:”POWERPACT”},{“name”:”Amps”,”normalizedValue”:”175A”,”rank”:4,”value”:”175A”},{“name”:”Number of Poles”,”normalizedValue”:”2″,”rank”:5,”value”:”2″},{“name”:”AC Voltage Rating”,”normalizedValue”:”600V AC”,”rank”:6,”value”:”600V AC”},{“name”:”Circuit Breaker Type”,”normalizedValue”:”Standard”,”rank”:7,”value”:”Standard”},{“name”:”Phase”,”normalizedValue”:”1″,”rank”:8,”value”:”1″},{“name”:”Circuit Breaker Actuator”,”normalizedValue”:”I-Line”,”rank”:9,”value”:”I-Line”},{“name”:”Circuit Breaker Mounting Style”,”normalizedValue”:”Plug In”,”rank”:10,”value”:”Plug In”},{“name”:”Max. AIR Rating”,”normalizedValue”:”65kA at 240V AC”,”rank”:11,”value”:”65kA at 240V AC”},{“name”:”Trip Type”,”normalizedValue”:”Thermal Magnetic”,”rank”:12,”value”:”Thermal Magnetic”},{“name”:”Instantaneous Trip”,”normalizedValue”:”Adjustable”,”rank”:13,”value”:”Adjustable”},{“name”:”Terminal Connection”,”normalizedValue”:”Lugs”,”rank”:14,”value”:”Lugs”},{“name”:”Phase Connection”,”normalizedValue”:”AB”,”rank”:15,”value”:”AB”},{“name”:”Frame Size”,”normalizedValue”:”250A/JG”,”rank”:16,”value”:”250A/JG”},{“name”:”Width”,”normalizedValue”:”4.1 in”,”rank”:17,”value”:”4.10 in”},{“name”:”Depth”,”normalizedValue”:”5 in”,”rank”:18,”value”:”5 in”},{“name”:”Height”,”normalizedValue”:”7-1/2 in”,”rank”:19,”value”:”7-1/2 in”},{“name”:”DC Voltage Rating”,”normalizedValue”:”250/500V DC”,”rank”:20,”value”:”250/500V DC”},{“name”:”Max. Wire Size”,”normalizedValue”:”4/0 AWG”,”value”:”4/0 AWG”},{“name”:”Low Amp Trip Setting”,”normalizedValue”:”875 A”,”value”:”875 A”},{“name”:”Min. Wire Size”,”normalizedValue”:”4 AWG”,”value”:”4 AWG”},{“name”:”For Use With”,”normalizedValue”:”I Line Panelboards”,”value”:”I Line Panelboards”},{“name”:”Standards”,”normalizedValue”:”BS, CCC, CE Marked, CEI, CSA Certified, Federal Specification W-C-375B/GEN, HACR, HID, IEC, NEMA, NMX, NOM, SWD, UL Listed, UNE, UTE, VDE”,”value”:”BS, CCC, CE Marked, CEI, CSA Certified, Federal Specification W-C-375B/GEN, HACR, HID, IEC, NEMA, NMX, NOM, SWD, UL Listed, UNE, UTE, VDE”},{“name”:”High Amp Trip Setting”,”normalizedValue”:”1,750 A”,”value”:”1,750 A”},{“name”:”Features”,”normalizedValue”:”Mercury Free; PVC Free”,”value”:”Mercury Free; PVC Free”},{“name”:”Application”,”normalizedValue”:”HACR rated Applications; Distribution”,”value”:”HACR rated Applications; Distribution”},{“name”:”Interrupt Rating”,”normalizedValue”:”65 kA at 220/240V AC, 35 kA at 380/440/415/480V AC, 18 kA at 500/525/600V AC, 20 kA at 250/500V DC”,”value”:”65 kA at 220/240V AC, 35 kA at 380/440/415/480V AC, 18 kA at 500/525/600V AC, 20 kA at 250/500V DC”},{“name”:”Product Certifications”,”normalizedValue”:”CSA, UL, NOM”,”value”:”UL; CSA; NOM”},{“name”:”Breaking Capacity Code”,”normalizedValue”:”G”,”value”:”G”},{“name”:”Long Time Pick-Up Adjustment Range”,”normalizedValue”:”0.25 to 1 x In”,”value”:”0.25 to 1 x In”},{“name”:”Operating Altitude”,”normalizedValue”:”Less than 6561.68 ft (2000 m) without derating; 5000 m with derating”,”value”:”Less than 6561.68 ft (2000 m) without derating; 5000 m with derating”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”600 V AC 50/60 Hz IEC 60947-3″,”value”:”600 V AC 50/60 Hz IEC 60947-3″},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”28 to 158°F (-2 to 70°C)”,”value”:”28 to 158°F (-2 to 70°C)”},{“name”:”Rated Service Breaking Capacity”,”normalizedValue”:”65 kA 220/240 V AC 50/60 Hz IEC 60947-2; 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2; 18 kA 500/525 V AC 50/60 Hz IEC 60947-2; 20 kA 250 V DC IEC 60947-2; 20 kA 500 V DC IEC 60947-2″,”value”:”65 kA 220/240 V AC 50/60 Hz IEC 60947-2; 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2; 18 kA 500/525 V AC 50/60 Hz IEC 60947-2; 20 kA 250 V DC IEC 60947-2; 20 kA 500 V DC IEC 60947-2″},{“name”:”Continuous Current Rating”,”normalizedValue”:”0.8″,”value”:”0.8″},{“name”:”Local Signalling”,”normalizedValue”:”Switched off (OFF) 1 trip indicator green)”,”value”:”Switched off (OFF) 1 trip indicator green)”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-58 to 185°F”,”value”:”-58 to 185°F (-50 to 85°C)”},{“name”:”Terminal Identifier”,”normalizedValue”:”AL175JD”,”value”:”AL175JD”},{“name”:”Network Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”AWG Gauge”,”normalizedValue”:”AWG 4 to AWG 4/0 aluminium/copper terminal”,”value”:”AWG 4 to AWG 4/0 aluminium/copper terminal”},{“name”:”Circuit Breaker Application”,”normalizedValue”:”HACR rated”,”value”:”HACR rated”},{“name”:”Pollution Degree”,”normalizedValue”:”3 IEC 60947-1″,”value”:”3 IEC 60947-1″},{“name”:”IP Degree Of Protection”,”normalizedValue”:”Front cover IP40″,”value”:”Front cover IP40″},{“name”:”Number Of Slots”,”normalizedValue”:”2 auxiliary switch OF plug-in); 1 alarm switch SD plug-in); 1 overcurrent trip switch SDE plug-in); 1 voltage release MN or MX plug-in)”,”value”:”2 auxiliary switch OF plug-in); 1 alarm switch SD plug-in); 1 overcurrent trip switch SDE plug-in); 1 voltage release MN or MX plug-in)”},{“name”:”Power Wire Stripping Length”,”normalizedValue”:”0.98 in”,”value”:”0.98 in (25 mm)”},{“name”:”Protection Type”,”normalizedValue”:”Overload protection; Short-circuit protection”,”value”:”Overload protection; Short-circuit protection”},{“name”:”Communication Interface”,”normalizedValue”:”Modbus, Ethernet”,”value”:”Modbus; Ethernet”},{“name”:”Device Application”,”normalizedValue”:”Distribution”,”value”:”Distribution”},{“name”:”Magnetic Tripping Current”,”normalizedValue”:”1,750 A”,”value”:”1750 A”},{“name”:”Suitability For Isolation”,”normalizedValue”:”Yes IEC 60947-2″,”value”:”Yes IEC 60947-2″},{“name”:”Tightening Torque”,”normalizedValue”:”221.27 lbf.in (25 N.m) 0.04 to 0.15 in² (25 to 95 mm²) (AWG 4 to AWG 4/0)”,”value”:”221.27 lbf.in (25 N.m) 0.04 to 0.15 in² (25 to 95 mm²) (AWG 4 to AWG 4/0)”},{“name”:”Quality Labels”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”Mounting Height”,”normalizedValue”:”4-1/2 in”,”value”:”4.5 in (114.30 mm)”},{“name”:”Rated Impulse Withstand Voltage”,”normalizedValue”:”8 kV IEC 60947-2″,”value”:”8 kV IEC 60947-2″},{“name”:”Breaking Capacity”,”normalizedValue”:”65 kA 240 V AC 50/60 Hz UL 489; 35 kA 480 V AC 50/60 Hz UL 489; 18 kA 600 V AC 50/60 Hz UL 489; 20 kA 250 V DC UL 489; 20 kA 500 V DC UL 489″,”value”:”65 kA 240 V AC 50/60 Hz UL 489; 35 kA 480 V AC 50/60 Hz UL 489; 18 kA 600 V AC 50/60 Hz UL 489; 20 kA 250 V DC UL 489; 20 kA 500 V DC UL 489″},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”750 V IEC 60947-2″,”value”:”750 V IEC 60947-2″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Molded Case Circuit Breaker, POWERPACT Series, 175A, 2 Pole, 600V AC, 65kA at 240V AC”