Molded Case Circuit Breaker, POWERPACT Series, 15A, 2 Pole, 600V AC, 65kA at 240V AC

$1108,99

Molded Case Circuit Breaker, 15 A Amps, AC Voltage Rating 600V AC, Max. AIR Rating 65kA at 240V AC, For Use With I Line Panelboards, Series HG, High Amp Trip Setting 750 A, Low Amp Trip Setting 350 A, Circuit Breaker Type Standard, Number of Poles 2, DC Voltage Rating 250V DC, Terminal Connection Lug, Trip Type Thermal Magnetic, Phase Single, Instantaneous Trip Fixed, Phase Connection AC, Frame Size 150A/HG, Circuit Breaker Mounting Style I-Line, Height 9.73 in, Width 2.94 in, Depth 4.8 in

9999 in stock

SKU: GRG1798614 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Molded Case Circuit Breaker”,”rank”:2,”value”:”Molded Case Circuit Breaker”},{“name”:”Series”,”normalizedValue”:”POWERPACT”,”rank”:3,”value”:”POWERPACT”},{“name”:”Amps”,”normalizedValue”:”15A”,”rank”:4,”value”:”15A”},{“name”:”Number of Poles”,”normalizedValue”:”2″,”rank”:5,”value”:”2″},{“name”:”AC Voltage Rating”,”normalizedValue”:”600V AC”,”rank”:6,”value”:”600V AC”},{“name”:”Circuit Breaker Type”,”normalizedValue”:”Standard”,”rank”:7,”value”:”Standard”},{“name”:”Phase”,”normalizedValue”:”1″,”rank”:8,”value”:”1″},{“name”:”Circuit Breaker Actuator”,”normalizedValue”:”I-Line”,”rank”:9,”value”:”I-Line”},{“name”:”Circuit Breaker Mounting Style”,”normalizedValue”:”Plug In”,”rank”:10,”value”:”Plug In”},{“name”:”Max. AIR Rating”,”normalizedValue”:”65kA at 240V AC”,”rank”:11,”value”:”65kA at 240V AC”},{“name”:”Trip Type”,”normalizedValue”:”Thermal Magnetic”,”rank”:12,”value”:”Thermal Magnetic”},{“name”:”Instantaneous Trip”,”normalizedValue”:”Fixed”,”rank”:13,”value”:”Fixed”},{“name”:”Terminal Connection”,”normalizedValue”:”Lugs”,”rank”:14,”value”:”Lugs”},{“name”:”Phase Connection”,”normalizedValue”:”AC”,”rank”:15,”value”:”AC”},{“name”:”Frame Size”,”normalizedValue”:”150A/HG”,”rank”:16,”value”:”150A/HG”},{“name”:”Width”,”normalizedValue”:”2.74 in”,”rank”:17,”value”:”2.74 in”},{“name”:”Depth”,”normalizedValue”:”4.36 in”,”rank”:18,”value”:”4.36 in”},{“name”:”Height”,”normalizedValue”:”6.4 in”,”rank”:19,”value”:”6.40 in”},{“name”:”DC Voltage Rating”,”normalizedValue”:”250/500V DC”,”rank”:20,”value”:”250/500V DC”},{“name”:”For Use With”,”normalizedValue”:”I Line Panelboards”,”value”:”I Line Panelboards”},{“name”:”High Amp Trip Setting”,”normalizedValue”:”750 A”,”value”:”750 A”},{“name”:”Standards”,”normalizedValue”:”CE, CSA, IEC, UL listed”,”value”:”CE, CSA, IEC, UL listed”},{“name”:”Max. Wire Size”,”normalizedValue”:”3 AWG”,”value”:”3 AWG”},{“name”:”Min. Wire Size”,”normalizedValue”:”14 AWG”,”value”:”14 AWG”},{“name”:”Low Amp Trip Setting”,”normalizedValue”:”350 A”,”value”:”350 A”},{“name”:”Application”,”normalizedValue”:”HACR rated Applications; Distribution”,”value”:”HACR rated Applications; Distribution”},{“name”:”Color”,”normalizedValue”:”Black”,”value”:”Black”},{“name”:”Interrupt Rating”,”normalizedValue”:”65 kA at 220/240V AC, 35 kA at 380/440/415/480V AC, 18 kA at 500/525/600V AC, 20 kA at 250/500V DC”,”value”:”65 kA at 220/240V AC, 35 kA at 380/440/415/480V AC, 18 kA at 500/525/600V AC, 20 kA at 250/500V DC”},{“name”:”Features”,”normalizedValue”:”Mercury Free; PVC Free”,”value”:”Mercury Free; PVC Free”},{“name”:”Max. Operating Temp.”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Rated Impulse Withstand Voltage”,”normalizedValue”:”8 kV IEC 60947-2″,”value”:”8 kV IEC 60947-2″},{“name”:”Circuit Breaker Application”,”normalizedValue”:”HACR rated”,”value”:”HACR rated”},{“name”:”Suitability For Isolation”,”normalizedValue”:”Yes IEC 60947-2″,”value”:”Yes IEC 60947-2″},{“name”:”Network Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Rated Service Breaking Capacity”,”normalizedValue”:”65 kA 220/240 V AC 50/60 Hz IEC 60947-2; 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2; 18 kA 500/525 V AC 50/60 Hz IEC 60947-2; 20 kA 250 V DC IEC 60947-2; 20 kA 500 V DC IEC 60947-2″,”value”:”65 kA 220/240 V AC 50/60 Hz IEC 60947-2; 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2; 18 kA 500/525 V AC 50/60 Hz IEC 60947-2; 20 kA 250 V DC IEC 60947-2; 20 kA 500 V DC IEC 60947-2″},{“name”:”Device Application”,”normalizedValue”:”Distribution”,”value”:”Distribution”},{“name”:”Pollution Degree”,”normalizedValue”:”3 IEC 60947-1″,”value”:”3 IEC 60947-1″},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-58 to 185°F”,”value”:”-58 to 185°F (-50 to 85°C)”},{“name”:”AWG Gauge”,”normalizedValue”:”AWG 14 to AWG 3/0 aluminium/copper terminal”,”value”:”AWG 14 to AWG 3/0 aluminium/copper terminal”},{“name”:”Mounting Height”,”normalizedValue”:”3 in”,”value”:”3 in (76.20 mm)”},{“name”:”Communication Interface”,”normalizedValue”:”Modbus, Ethernet”,”value”:”Modbus; Ethernet”},{“name”:”Operating Altitude”,”normalizedValue”:”Less than 6561.68 ft (2000 m) without derating; 5000 m with derating”,”value”:”Less than 6561.68 ft (2000 m) without derating; 5000 m with derating”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”690 V AC 50/60 Hz IEC 60947-3″,”value”:”690 V AC 50/60 Hz IEC 60947-3″},{“name”:”Number Of Slots”,”normalizedValue”:”2 auxiliary switch OF plug-in); 1 alarm switch SD plug-in); 1 overcurrent trip switch SDE plug-in); 1 voltage release MN or MX plug-in)”,”value”:”2 auxiliary switch OF plug-in); 1 alarm switch SD plug-in); 1 overcurrent trip switch SDE plug-in); 1 voltage release MN or MX plug-in)”},{“name”:”Breaking Capacity”,”normalizedValue”:”65 kA 240 V AC 50/60 Hz UL 489; 35 kA 480 V AC 50/60 Hz UL 489; 18 kA 600 V AC 50/60 Hz UL 489; 20 kA 250 V DC UL 489; 20 kA 500 V DC UL 489″,”value”:”65 kA 240 V AC 50/60 Hz UL 489; 35 kA 480 V AC 50/60 Hz UL 489; 18 kA 600 V AC 50/60 Hz UL 489; 20 kA 250 V DC UL 489; 20 kA 500 V DC UL 489″},{“name”:”Breaking Capacity Code”,”normalizedValue”:”G”,”value”:”G”},{“name”:”IP Degree Of Protection”,”normalizedValue”:”Front cover IP40 IEC 60529″,”value”:”Front cover IP40 IEC 60529″},{“name”:”Terminal Identifier”,”normalizedValue”:”AL150HD”,”value”:”AL150HD”},{“name”:”Tightening Torque”,”normalizedValue”:”44.25 lbf.in (5 N.m) 0.00 to 0.01 in² (2.5 to 6 mm²) (AWG 14 to AWG 10); 123.91 lbf.in (14 N.m) 0.02 to 0.15 in² (10 to 95 mm²) (AWG 8 to AWG 3/0)”,”value”:”44.25 lbf.in (5 N.m) 0.00 to 0.01 in² (2.5 to 6 mm²) (AWG 14 to AWG 10); 123.91 lbf.in (14 N.m) 0.02 to 0.15 in² (10 to 95 mm²) (AWG 8 to AWG 3/0)”},{“name”:”Product Certifications”,”normalizedValue”:”CSA, UL, NOM”,”value”:”UL; CSA; NOM”},{“name”:”Power Wire Stripping Length”,”normalizedValue”:”0.63 in”,”value”:”0.63 in (16 mm)”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”28 to 158°F (-2 to 70°C)”,”value”:”28 to 158°F (-2 to 70°C)”},{“name”:”Protected Poles Description”,”normalizedValue”:”2t”,”value”:”2t”},{“name”:”Continuous Current Rating”,”normalizedValue”:”0.8″,”value”:”0.8″},{“name”:”Quality Labels”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”Local Signalling”,”normalizedValue”:”Switched off (OFF) 1 trip indicator green)”,”value”:”Switched off (OFF) 1 trip indicator green)”},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”750 V IEC 60947-2″,”value”:”750 V IEC 60947-2″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Molded Case Circuit Breaker, POWERPACT Series, 15A, 2 Pole, 600V AC, 65kA at 240V AC”