Molded Case Circuit Breaker, PDG Series, 400A, 3 Pole, 600V AC, 35kA at 480V AC, A Curve

$4349,99

Circuit Breaker, 400 A Amps, AC Voltage Rating 600V AC, Max. AIR Rating 35 kA at 480V AC, For Use With Power Defense, Circuit Breaker Type Standard, Number of Poles 3, DC Voltage Rating Not Rated, Terminal Connection Standard Line and Load Lugs, Trip Type Thermo Magnetic, Phase Three, Instantaneous Trip Fixed; Adjustable, Phase Connection ABC, Frame Size 800A/Frame 4, Height 16 in, Width 8.25 in, Depth 4.38 in, Min. Wire Size 500 AWG, Max. Wire Size 1 AWG, Max. Operating Temp. 158 Degrees F

9999 in stock

SKU: GRG200901876 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Molded Case Circuit Breaker”,”rank”:2,”value”:”Molded Case Circuit Breaker”},{“name”:”Series”,”normalizedValue”:”PDG”,”rank”:3,”value”:”PDG”},{“name”:”Amps”,”normalizedValue”:”400A”,”rank”:4,”value”:”400A”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”rank”:5,”value”:”3″},{“name”:”AC Voltage Rating”,”normalizedValue”:”600V AC”,”rank”:6,”value”:”600V AC”},{“name”:”Circuit Breaker Type”,”normalizedValue”:”Standard”,”rank”:7,”value”:”Standard”},{“name”:”Phase”,”normalizedValue”:”3″,”rank”:8,”value”:”3″},{“name”:”Max. AIR Rating”,”normalizedValue”:”35kA at 480V AC”,”rank”:11,”value”:”35kA at 480V AC”},{“name”:”Trip Type”,”normalizedValue”:”Thermal Magnetic”,”rank”:12,”value”:”Thermal Magnetic”},{“name”:”Instantaneous Trip”,”normalizedValue”:”Fixed, Adjustable”,”rank”:13,”value”:”Adjustable/Fixed”},{“name”:”Terminal Connection”,”normalizedValue”:”Lugs”,”rank”:14,”value”:”Lugs”},{“name”:”Phase Connection”,”normalizedValue”:”ABC”,”rank”:15,”value”:”ABC”},{“name”:”Frame Size”,”normalizedValue”:”800A/Frame 4″,”rank”:16,”value”:”800A/Frame 4″},{“name”:”Width”,”normalizedValue”:”8-1/4 in”,”rank”:17,”value”:”8-1/4 in”},{“name”:”Depth”,”normalizedValue”:”4.38 in”,”rank”:18,”value”:”4.38 in”},{“name”:”Height”,”normalizedValue”:”16 in”,”rank”:19,”value”:”16 in”},{“name”:”DC Voltage Rating”,”normalizedValue”:”Not Rated”,”rank”:20,”value”:”Not Rated”},{“name”:”Curve Type”,”normalizedValue”:”A”,”rank”:21,”value”:”A”},{“name”:”Standards”,”normalizedValue”:”CCC, CSA, IEC 60947-2, RoHS, UL 489″,”value”:”CCC, CSA, IEC 60947-2, RoHS, UL 489″},{“name”:”Min. Wire Size”,”normalizedValue”:”500 AWG”,”value”:”500 AWG”},{“name”:”Interrupt Rating”,”normalizedValue”:”65 kA at 480V AC, 30 kA Icu/25 kA Ics/63 kA Icm at 525V”,”value”:”65 kA at 480V AC, 30 kA Icu/25 kA Ics/63 kA Icm at 525V”},{“name”:”Max. Wire Size”,”normalizedValue”:”1 AWG”,”value”:”1 AWG”},{“name”:”For Use With”,”normalizedValue”:”Power Defense”,”value”:”Power Defense”},{“name”:”Frame Type”,”normalizedValue”:”Complete Breaker”,”value”:”Complete Breaker”},{“name”:”Max. Operating Temp.”,”normalizedValue”:”158 deg F”,”value”:”158 Degrees F”},{“name”:”Min. Operating Temp.”,”normalizedValue”:”-4 deg F”,”value”:”-4 Degrees F”},{“name”:”Certifications”,”normalizedValue”:”CSA;IEC 60947-2;UL 489;CCC Marked”,”value”:”CSA;IEC 60947-2;UL 489;CCC Marked”},{“name”:”Class”,”normalizedValue”:”Class A”,”value”:”Class A”},{“name”:”Frame”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Molded Case Circuit Breaker, PDG Series, 400A, 3 Pole, 600V AC, 35kA at 480V AC, A Curve”