Description
[{“name”:”Item”,”normalizedValue”:”Molded Case Circuit Breaker”,”rank”:2,”value”:”Molded Case Circuit Breaker”},{“name”:”Series”,”normalizedValue”:”PDG”,”rank”:3,”value”:”PDG”},{“name”:”Amps”,”normalizedValue”:”20A”,”rank”:4,”value”:”20A”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”rank”:5,”value”:”3″},{“name”:”AC Voltage Rating”,”normalizedValue”:”600V AC”,”rank”:6,”value”:”600V AC”},{“name”:”Circuit Breaker Type”,”normalizedValue”:”Standard”,”rank”:7,”value”:”Standard”},{“name”:”Phase”,”normalizedValue”:”3″,”rank”:8,”value”:”3″},{“name”:”Max. AIR Rating”,”normalizedValue”:”25kA at 480V AC”,”rank”:11,”value”:”25kA at 480V AC”},{“name”:”Trip Type”,”normalizedValue”:”Thermal Magnetic”,”rank”:12,”value”:”Thermal Magnetic”},{“name”:”Instantaneous Trip”,”normalizedValue”:”Fixed”,”rank”:13,”value”:”Fixed”},{“name”:”Terminal Connection”,”normalizedValue”:”Standard Terminals Load Only”,”rank”:14,”value”:”Standard Terminals Load Only”},{“name”:”Phase Connection”,”normalizedValue”:”ABC”,”rank”:15,”value”:”ABC”},{“name”:”Frame Size”,”normalizedValue”:”225A/Frame 2″,”rank”:16,”value”:”225A/Frame 2″},{“name”:”Width”,”normalizedValue”:”4.11 in”,”rank”:17,”value”:”4.11 in”},{“name”:”Depth”,”normalizedValue”:”3-1/2 in”,”rank”:18,”value”:”3.5 in”},{“name”:”Height”,”normalizedValue”:”6 in”,”rank”:19,”value”:”6 in”},{“name”:”DC Voltage Rating”,”normalizedValue”:”Not Rated”,”rank”:20,”value”:”Not Rated”},{“name”:”Curve Type”,”normalizedValue”:”A”,”rank”:21,”value”:”A”},{“name”:”Interrupt Rating”,”normalizedValue”:”25 kA at 480V AC, 25 kA at 480V”,”value”:”25 kA at 480V AC, 25 kA at 480V”},{“name”:”Max. Wire Size”,”normalizedValue”:”1/0 AWG”,”value”:”1/0 AWG”},{“name”:”Frame Type”,”normalizedValue”:”Complete Breaker”,”value”:”Complete Breaker”},{“name”:”Min. Wire Size”,”normalizedValue”:”14 AWG”,”value”:”14 AWG”},{“name”:”Standards”,”normalizedValue”:”CCC, CSA, IEC 60947-2, UL 489″,”value”:”CCC, CSA, IEC 60947-2, UL 489″},{“name”:”Min. Operating Temp.”,”normalizedValue”:”-4 deg F”,”value”:”-4 Degrees F”},{“name”:”Max. Operating Temp.”,”normalizedValue”:”158 deg F”,”value”:”158 Degrees F”},{“name”:”Frame”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Interrupt Rating Range”,”normalizedValue”:”25 kAIC @480V (UL);20 kAIC Icu/ 20 kAIC Ics/ 42 kAIC Icm @480V Brazil (IEC);10 kAIC Icu @125 Vdc;18 kAIC Icu/ 15/13 kAIC Ics/ 37.8 kAIC Icm @525V South Africa (IEC);35 kAIC @240V (UL);25 kAIC Icu/ 20 kAIC Ics/ 52.5 kAIC Icm @440V (IEC);35 kAIC Icu/ 35 kAIC Ics/ 73.5 kAIC Icm @240V (IEC);14 kAIC @600V (UL/CSA);10 kAIC Icu @250 Vdc;25 kAIC Icu/ 25 kAIC Ics/ 52.5 kAIC Icm @380-415V (IEC)”,”value”:”25 kAIC @480V (UL);20 kAIC Icu/ 20 kAIC Ics/ 42 kAIC Icm @480V Brazil (IEC);10 kAIC Icu @125 Vdc;18 kAIC Icu/ 15/13 kAIC Ics/ 37.8 kAIC Icm @525V South Africa (IEC);35 kAIC @240V (UL);25 kAIC Icu/ 20 kAIC Ics/ 52.5 kAIC Icm @440V (IEC);35 kAIC Icu/ 35 kAIC Ics/ 73.5 kAIC Icm @240V (IEC);14 kAIC @600V (UL/CSA);10 kAIC Icu @250 Vdc;25 kAIC Icu/ 25 kAIC Ics/ 52.5 kAIC Icm @380-415V (IEC)”},{“name”:”Class”,”normalizedValue”:”Class A”,”value”:”Class A”},{“name”:”Product Width”,”normalizedValue”:”104.6 mm”,”value”:”104.6 mm”},{“name”:”Certifications”,”normalizedValue”:”CSA;UL 489;IEC 60947-2;CCC Marked”,”value”:”CSA;UL 489;IEC 60947-2;CCC Marked”},{“name”:”Product Name”,”normalizedValue”:”Eaton Power Defense molded case circuit breaker”,”value”:”Eaton Power Defense molded case circuit breaker”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Dominican Republic”,”value”:”Dominican Republic”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.