Description
[{“name”:”Item”,”normalizedValue”:”Molded Case Circuit Breaker”,”rank”:2,”value”:”Molded Case Circuit Breaker”},{“name”:”Series”,”normalizedValue”:”PDG”,”rank”:3,”value”:”PDG”},{“name”:”Amps”,”normalizedValue”:”1200A”,”rank”:4,”value”:”1200A”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”rank”:5,”value”:”3″},{“name”:”AC Voltage Rating”,”normalizedValue”:”600V AC”,”rank”:6,”value”:”600V AC”},{“name”:”Circuit Breaker Type”,”normalizedValue”:”Standard”,”rank”:7,”value”:”Standard”},{“name”:”Phase”,”normalizedValue”:”3″,”rank”:8,”value”:”3″},{“name”:”Max. AIR Rating”,”normalizedValue”:”65kA at 480V AC”,”rank”:11,”value”:”65kA at 480V AC”},{“name”:”Trip Type”,”normalizedValue”:”Electronic”,”rank”:12,”value”:”Electronic”},{“name”:”Terminal Connection”,”normalizedValue”:””,”rank”:14,”value”:”Not Applicable”},{“name”:”Phase Connection”,”normalizedValue”:”ABC”,”rank”:15,”value”:”ABC”},{“name”:”Frame Size”,”normalizedValue”:”1200A/Frame 5″,”rank”:16,”value”:”1200A/Frame 5″},{“name”:”Width”,”normalizedValue”:”8.24 in”,”rank”:17,”value”:”8.24 in”},{“name”:”Depth”,”normalizedValue”:”5-1/2 in”,”rank”:18,”value”:”5.5 in”},{“name”:”Height”,”normalizedValue”:”16 in”,”rank”:19,”value”:”16 in”},{“name”:”DC Voltage Rating”,”normalizedValue”:”Not Rated”,”rank”:20,”value”:”Not Rated”},{“name”:”Curve Type”,”normalizedValue”:”A”,”rank”:21,”value”:”A”},{“name”:”High Amp Trip Setting”,”normalizedValue”:”1,200 A”,”value”:”1200 A”},{“name”:”Features”,”normalizedValue”:”Relays”,”value”:”Relays”},{“name”:”Standards”,”normalizedValue”:”CCC, CSA, IEC, UL”,”value”:”CCC, CSA, IEC, UL”},{“name”:”Max. Wire Size”,”normalizedValue”:”3/0 AWG”,”value”:”3/0 AWG”},{“name”:”Min. Wire Size”,”normalizedValue”:”400 AWG”,”value”:”400 AWG”},{“name”:”Frame Type”,”normalizedValue”:”Complete Breaker”,”value”:”Complete Breaker”},{“name”:”Interrupt Rating”,”normalizedValue”:”65 kA at 480V AC, 100 kA at 240V”,”value”:”65 kA at 480V AC, 100 kA at 240V”},{“name”:”Max. Operating Temp.”,”normalizedValue”:”158 deg F”,”value”:”158 Degrees F”},{“name”:”Min. Operating Temp.”,”normalizedValue”:”-4 deg F”,”value”:”-4 Degrees F”},{“name”:”Product Name”,”normalizedValue”:”Eaton Power Defense molded case circuit breaker”,”value”:”Eaton Power Defense molded case circuit breaker”},{“name”:”Frame”,”normalizedValue”:”5″,”value”:”5″},{“name”:”Class”,”normalizedValue”:”Class A”,”value”:”Class A”},{“name”:”Certifications”,”normalizedValue”:”IEC 60947-2;CSA;UL 489;CCC Marked”,”value”:”IEC 60947-2;CSA;UL 489;CCC Marked”},{“name”:”Interrupt Rating Range”,”normalizedValue”:”100 kAIC @240V (UL);50 kAIC Icu/ 30 kAIC Ics/ 105 kAIC Icm @480V Brazil (IEC);30 kAIC Icu/ 25 kAIC Ics/ 63 kAIC Icm @525V South Africa (IEC);35 kAIC @600/347V (UL);100 kAIC Icu/ 100 kAIC Ics/ 220 kAIC Icm @240V (IEC);65 kAIC @480/277V (UL);70 kAIC Icu/ 53 kAIC Ics/ 154 kAIC Icm @380-415V (IEC);15 kAIC Icu/ 7.5 kAIC Ics/ 31.5 kAIC Icm @690V (IEC);50 kAIC Icu/ 40 kAIC Ics/ 105 kAIC Icm @440V (IEC)”,”value”:”100 kAIC @240V (UL);50 kAIC Icu/ 30 kAIC Ics/ 105 kAIC Icm @480V Brazil (IEC);30 kAIC Icu/ 25 kAIC Ics/ 63 kAIC Icm @525V South Africa (IEC);35 kAIC @600/347V (UL);100 kAIC Icu/ 100 kAIC Ics/ 220 kAIC Icm @240V (IEC);65 kAIC @480/277V (UL);70 kAIC Icu/ 53 kAIC Ics/ 154 kAIC Icm @380-415V (IEC);15 kAIC Icu/ 7.5 kAIC Ics/ 31.5 kAIC Icm @690V (IEC);50 kAIC Icu/ 40 kAIC Ics/ 105 kAIC Icm @440V (IEC)”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.