Description
[{“name”:”Item”,”normalizedValue”:”Molded Case Circuit Breaker”,”rank”:2,”value”:”Molded Case Circuit Breaker”},{“name”:”Series”,”normalizedValue”:”PDG”,”rank”:3,”value”:”PDG”},{“name”:”Amps”,”normalizedValue”:”100A”,”rank”:4,”value”:”100A”},{“name”:”Number of Poles”,”normalizedValue”:”2″,”rank”:5,”value”:”2″},{“name”:”AC Voltage Rating”,”normalizedValue”:”600V AC”,”rank”:6,”value”:”600V AC”},{“name”:”Circuit Breaker Type”,”normalizedValue”:”Standard”,”rank”:7,”value”:”Standard”},{“name”:”Phase”,”normalizedValue”:”3″,”rank”:8,”value”:”3″},{“name”:”Max. AIR Rating”,”normalizedValue”:”65kA at 480V AC”,”rank”:11,”value”:”65kA at 480V AC”},{“name”:”Trip Type”,”normalizedValue”:”Thermal Magnetic”,”rank”:12,”value”:”Thermal Magnetic”},{“name”:”Instantaneous Trip”,”normalizedValue”:”Fixed”,”rank”:13,”value”:”Fixed”},{“name”:”Terminal Connection”,”normalizedValue”:”Line”,”rank”:14,”value”:”Standard Line And Load Lugs”},{“name”:”Phase Connection”,”normalizedValue”:”AB”,”rank”:15,”value”:”AB”},{“name”:”Frame Size”,”normalizedValue”:”125A/Frame 1″,”rank”:16,”value”:”125A/Frame 1″},{“name”:”Width”,”normalizedValue”:”2 in”,”rank”:17,”value”:”2 in”},{“name”:”Depth”,”normalizedValue”:”2.99 in”,”rank”:18,”value”:”2.99 in”},{“name”:”Height”,”normalizedValue”:”139.7 mm”,”rank”:19,”value”:”139.7 mm”},{“name”:”DC Voltage Rating”,”normalizedValue”:”Not Rated”,”rank”:20,”value”:”Not Rated”},{“name”:”Curve Type”,”normalizedValue”:”A”,”rank”:21,”value”:”A”},{“name”:”Standards”,”normalizedValue”:”CCC, CSA, IEC 60947-2, RoHS, UL 489″,”value”:”CCC, CSA, IEC 60947-2, RoHS, UL 489″},{“name”:”Max. Wire Size”,”normalizedValue”:”3/0 AWG”,”value”:”3/0 AWG”},{“name”:”Frame Type”,”normalizedValue”:”Complete Breaker”,”value”:”Complete Breaker”},{“name”:”Min. Wire Size”,”normalizedValue”:”14 AWG”,”value”:”14 AWG”},{“name”:”Interrupt Rating”,”normalizedValue”:”65 kA at 480V AC, 70 kA Icu/50 kA Ics/154 kA Icm at 380-415V”,”value”:”65 kA at 480V AC, 70 kA Icu/50 kA Ics/154 kA Icm at 380-415V”},{“name”:”Max. Operating Temp.”,”normalizedValue”:”158 deg F”,”value”:”158 Degrees F”},{“name”:”Min. Operating Temp.”,”normalizedValue”:”-4 deg F”,”value”:”-4 Degrees F”},{“name”:”Product Width”,”normalizedValue”:”50.8 mm”,”value”:”50.8 mm”},{“name”:”Product Name”,”normalizedValue”:”Eaton Power Defense molded case circuit breaker”,”value”:”Eaton Power Defense molded case circuit breaker”},{“name”:”Certifications”,”normalizedValue”:”CSA;IEC 60947-2;UL 489;CCC Marked”,”value”:”CSA;IEC 60947-2;UL 489;CCC Marked”},{“name”:”Rated Operation Voltage (UE) at AC – Max”,”normalizedValue”:”600″,”value”:”600″},{“name”:”Class”,”normalizedValue”:”Class A”,”value”:”Class A”},{“name”:”Switch Off Technique”,”normalizedValue”:”Thermomagnetic”,”value”:”Thermomagnetic”},{“name”:”Interrupt Rating Range”,”normalizedValue”:”70 kAIC Icu/ 50 kAIC Ics/ 154 kAIC Icm @380-415V (IEC);35 kAIC Icu @250 Vdc;100 kAIC @240V (UL);35 kAIC Icu @125 Vdc;65 kAIC @480V (UL);25 kAIC @600V (UL/CSA);100 kAIC Icu/ 100 kAIC Ics/ 220 kAIC Icm @240V (IEC)”,”value”:”70 kAIC Icu/ 50 kAIC Ics/ 154 kAIC Icm @380-415V (IEC);35 kAIC Icu @250 Vdc;100 kAIC @240V (UL);35 kAIC Icu @125 Vdc;65 kAIC @480V (UL);25 kAIC @600V (UL/CSA);100 kAIC Icu/ 100 kAIC Ics/ 220 kAIC Icm @240V (IEC)”},{“name”:”Frame”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Dominican Republic”,”value”:”Dominican Republic”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.