Description
[{“name”:”Item”,”normalizedValue”:”Molded Case Circuit Breaker”,”rank”:2,”value”:”Molded Case Circuit Breaker”},{“name”:”Series”,”normalizedValue”:”NG”,”rank”:3,”value”:”NG”},{“name”:”Amps”,”normalizedValue”:”1,200A”,”rank”:4,”value”:”1,200A”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”rank”:5,”value”:”3″},{“name”:”AC Voltage Rating”,”normalizedValue”:”600V AC”,”rank”:6,”value”:”600V AC”},{“name”:”Circuit Breaker Type”,”normalizedValue”:”LSIG Functionality”,”rank”:7,”value”:”LSIG Functionality”},{“name”:”Phase”,”normalizedValue”:”3″,”rank”:8,”value”:”3″},{“name”:”Circuit Breaker Actuator”,”normalizedValue”:”Toggle”,”rank”:9,”value”:”Toggle”},{“name”:”Circuit Breaker Mounting Style”,”normalizedValue”:”Free Standing”,”rank”:10,”value”:”Free Standing”},{“name”:”Max. AIR Rating”,”normalizedValue”:”65kA at 480V AC”,”rank”:11,”value”:”65kA at 480V AC”},{“name”:”Trip Type”,”normalizedValue”:”Thermal Magnetic”,”rank”:12,”value”:”Thermal Magnetic”},{“name”:”Instantaneous Trip”,”normalizedValue”:”Adjustable”,”rank”:13,”value”:”Adjustable”},{“name”:”Terminal Connection”,”normalizedValue”:”Line, Load Lug”,”rank”:14,”value”:”Line/Load Lug”},{“name”:”Phase Connection”,”normalizedValue”:”ABC”,”rank”:15,”value”:”ABC”},{“name”:”Frame Size”,”normalizedValue”:”1200A/N”,”rank”:16,”value”:”1200A/N”},{“name”:”Width”,”normalizedValue”:”9 in”,”rank”:17,”value”:”9 in”},{“name”:”Depth”,”normalizedValue”:”6 in”,”rank”:18,”value”:”6 in”},{“name”:”Height”,”normalizedValue”:”9 in”,”rank”:19,”value”:”9 in”},{“name”:”DC Voltage Rating”,”normalizedValue”:”250V DC”,”rank”:20,”value”:”250V DC”},{“name”:”High Amp Trip Setting”,”normalizedValue”:”1,200 A”,”value”:”1,200 A”},{“name”:”Min. Wire Size”,”normalizedValue”:”4 AWG”,”value”:”4 AWG”},{“name”:”Max. Wire Size”,”normalizedValue”:”500 MCM”,”value”:”500 MCM”},{“name”:”For Use With”,”normalizedValue”:”Allen Bradley MCC, Eaton MCC Eaton, Rockwell Automation Enclosed Control, Switchboard, Westinghouse”,”value”:”Allen Bradley MCC, Eaton MCC Eaton, Rockwell Automation Enclosed Control, Switchboard, Westinghouse”},{“name”:”Standards”,”normalizedValue”:”CSA Certified, IEC Rated, UL Listed”,”value”:”CSA Certified, IEC Rated, UL Listed”},{“name”:”Low Amp Trip Setting”,”normalizedValue”:”800 A”,”value”:”800 A”},{“name”:”Interrupt Rating”,”normalizedValue”:”100 kA at 240V AC”,”value”:”100 kA at 240V AC”},{“name”:”Max. Operating Temp.”,”normalizedValue”:”158 deg F”,”value”:”158 Degrees F”},{“name”:”Min. Operating Temp.”,”normalizedValue”:”-4 deg F”,”value”:”-4 Degrees F”},{“name”:”Frequency Rating”,”normalizedValue”:”50 to 60 Hz”,”value”:”50 to 60 Hz”},{“name”:”Compliances”,”normalizedValue”:”HACR Rated”,”value”:”HACR Rated”},{“name”:”Certifications”,”normalizedValue”:”CSA Certified;UL Listed”,”value”:”CSA Certified;UL Listed”},{“name”:”Product Name”,”normalizedValue”:”Eaton Series G molded case circuit breaker”,”value”:”Eaton Series G electronic molded case circuit breaker”},{“name”:”Rating”,”normalizedValue”:”80% rated”,”value”:”80% rated”},{“name”:”Mounting”,”normalizedValue”:”Free Standing”,”value”:”Free Standing”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.