Description
[{“name”:”Item”,”normalizedValue”:”Molded Case Circuit Breaker”,”rank”:2,”value”:”Molded Case Circuit Breaker”},{“name”:”Series”,”normalizedValue”:”MGA”,”rank”:3,”value”:”MGA”},{“name”:”Amps”,”normalizedValue”:”800A”,”rank”:4,”value”:”800A”},{“name”:”Number of Poles”,”normalizedValue”:”2″,”rank”:5,”value”:”2″},{“name”:”AC Voltage Rating”,”normalizedValue”:”600V AC”,”rank”:6,”value”:”600V AC”},{“name”:”Circuit Breaker Type”,”normalizedValue”:”Standard”,”rank”:7,”value”:”Standard”},{“name”:”Circuit Breaker Actuator”,”normalizedValue”:”Operating Handle”,”rank”:9,”value”:”Operating Handle”},{“name”:”Circuit Breaker Mounting Style”,”normalizedValue”:”I-Line”,”rank”:10,”value”:”I-Line”},{“name”:”Max. AIR Rating”,”normalizedValue”:”65kA at 240V AC”,”rank”:11,”value”:”65kA at 240V AC”},{“name”:”Trip Type”,”normalizedValue”:”Electronic”,”rank”:12,”value”:”Electronic”},{“name”:”Terminal Connection”,”normalizedValue”:”Lug, I-Line”,”rank”:14,”value”:”I-Line, Lug”},{“name”:”Phase Connection”,”normalizedValue”:”AC”,”rank”:15,”value”:”AC”},{“name”:”Frame Size”,”normalizedValue”:”800A, M”,”rank”:16,”value”:”800A/M”},{“name”:”Width”,”normalizedValue”:”8.27 in”,”rank”:17,”value”:”8.27 in”},{“name”:”Depth”,”normalizedValue”:”8.05 in”,”rank”:18,”value”:”8.05 in”},{“name”:”Height”,”normalizedValue”:”12.86 in”,”rank”:19,”value”:”12.86 in”},{“name”:”DC Voltage Rating”,”normalizedValue”:”Not Rated”,”rank”:20,”value”:”Not Rated”},{“name”:”Standards”,”normalizedValue”:”UL, CSA, NEMA, NOM, CE”,”value”:”UL, CSA, NEMA, NOM, CE”},{“name”:”Features”,”normalizedValue”:”Mercury Free; PVC Free”,”value”:”Mercury Free; PVC Free”},{“name”:”Color”,”normalizedValue”:”Black”,”value”:”Black”},{“name”:”Max. Wire Size”,”normalizedValue”:”(3) 500 kcmil (Cu/Al)”,”value”:”(3) 500 kcmil (Cu/Al)”},{“name”:”Min. Wire Size”,”normalizedValue”:”(3) 3/0 AWG (Cu/Al)”,”value”:”(3) 3/0 AWG (Cu/Al)”},{“name”:”High Amp Trip Setting”,”normalizedValue”:”1600 to 8000 A”,”value”:”1600 to 8000 A”},{“name”:”Interrupt Rating”,”normalizedValue”:”25 kA at 240V AC, 20 kA at 380/415V AC, 65 kA at 240V AC, 35 kA at 380/415/480V AC, 18 kA at 600V AC, 50 kA at 240V AC”,”value”:”25 kA at 240V AC, 20 kA at 380/415V AC, 65 kA at 240V AC, 35 kA at 380/415/480V AC, 18 kA at 600V AC, 50 kA at 240V AC”},{“name”:”Application”,”normalizedValue”:”HACR rated Applications; Distribution”,”value”:”HACR rated Applications; Distribution”},{“name”:”Device Application”,”normalizedValue”:”Distribution”,”value”:”Distribution”},{“name”:”AWG Gauge”,”normalizedValue”:”3 x AWG 3/0 to 3 x 500 kcmil aluminium/copper”,”value”:”3 x AWG 3/0 to 3 x 500 kcmil aluminium/copper”},{“name”:”Product Certifications”,”normalizedValue”:”CSA, UL, NOM”,”value”:”UL; CSA; NOM”},{“name”:”Breaking Capacity”,”normalizedValue”:”AIR 65 kA 240 V AC 50/60 Hz UL 489; AIR 35 kA 480 V AC 50/60 Hz UL 489; AIR 18 kA 600 V AC 50/60 Hz UL 489; Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2; Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2″,”value”:”AIR 65 kA 240 V AC 50/60 Hz UL 489; AIR 35 kA 480 V AC 50/60 Hz UL 489; AIR 18 kA 600 V AC 50/60 Hz UL 489; Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2; Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2″},{“name”:”Tightening Torque”,”normalizedValue”:”442.54 lbf.in (50 N.m) 0.15 to 0.37 in² (95 to 240 mm²) (3 x AWG 3/0 to 3 x 500 kcmil)”,”value”:”442.54 lbf.in (50 N.m) 0.15 to 0.37 in² (95 to 240 mm²) (3 x AWG 3/0 to 3 x 500 kcmil)”},{“name”:”Rated Impulse Withstand Voltage”,”normalizedValue”:”8 kV IEC 60947-2″,”value”:”8 kV IEC 60947-2″},{“name”:”Mounting Height”,”normalizedValue”:”9 in”,”value”:”9 in (228.60 mm)”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-58 to 185°F”,”value”:”-58 to 185°F (-50 to 85°C)”},{“name”:”Suitability For Isolation”,”normalizedValue”:”Yes IEC 60947-2″,”value”:”Yes IEC 60947-2″},{“name”:”Number Of Slots”,”normalizedValue”:”2″,”value”:”2 auxiliary switch OF plug-in; 1 alarm switch SD plug-in; 1 voltage release MN or MX plug-in)”},{“name”:”Power Wire Stripping Length”,”normalizedValue”:”0.98 in”,”value”:”0.98 in (25 mm)”},{“name”:”Continuous Current Rating”,”normalizedValue”:”0.8″,”value”:”0.8″},{“name”:”Utilisation Category”,”normalizedValue”:”Category A”,”value”:”Category A”},{“name”:”Breaking Capacity Code”,”normalizedValue”:”G”,”value”:”G”},{“name”:”Product Name”,”normalizedValue”:”PowerPact M”,”value”:”PowerPact M”},{“name”:”IP Degree Of Protection”,”normalizedValue”:”IP40″,”value”:”IP40″},{“name”:”Circuit Breaker Application”,”normalizedValue”:”HACR rated”,”value”:”HACR rated”},{“name”:”Rated Service Breaking Capacity”,”normalizedValue”:”25 kA 240 V AC 50/60 Hz IEC 60947-2; 20 kA 380/415 V AC 50/60 Hz IEC 60947-2″,”value”:”25 kA 240 V AC 50/60 Hz IEC 60947-2; 20 kA 380/415 V AC 50/60 Hz IEC 60947-2″},{“name”:”Long Time Pick-Up Adjustment Range”,”normalizedValue”:”300 to 800 A”,”value”:”300 to 800 A”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”600 V AC 50/60 Hz UL 489″,”value”:”600 V AC 50/60 Hz UL 489″},{“name”:”Quality Labels”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”Operating Altitude”,”normalizedValue”:”Less than 6561.68 ft (2000 m) without derating; 13123.36 ft (4000 m) with derating”,”value”:”Less than 6561.68 ft (2000 m) without derating; 13123.36 ft (4000 m) with derating”},{“name”:”Local Signalling”,”normalizedValue”:”1 trip indicator green)”,”value”:”1 trip indicator green)”},{“name”:”Trip Unit Name”,”normalizedValue”:”ET 1.0″,”value”:”ET 1.0″},{“name”:”Pollution Degree”,”normalizedValue”:”3 IEC 60947-1″,”value”:”3 IEC 60947-1″},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-13 to 158°F (-25 to 70°C)”,”value”:”-13 to 158°F (-25 to 70°C)”},{“name”:”Terminal Identifier”,”normalizedValue”:”AL800M23K”,”value”:”AL800M23K”},{“name”:”Network Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”750 V IEC 60947-2″,”value”:”750 V IEC 60947-2″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.