Molded Case Circuit Breaker, LA Series, 400A, 3 Pole, 600V AC, 42kA at 240V AC

$4658,99

Molded Case Circuit Breaker, 400 A Amps, AC Voltage Rating 600V AC, Max. AIR Rating 42kA at 120/240V AC, For Use With I Line Panelboards, Series LA, High Amp Trip Setting 4,000 A, Low Amp Trip Setting 2,000 A, Circuit Breaker Type Standard, Number of Poles 3, DC Voltage Rating 250V DC, Terminal Connection Lug, Trip Type Thermal Magnetic, Phase Three, Instantaneous Trip Instantaneous, Phase Connection ABC, Frame Size 400A/LA, Circuit Breaker Mounting Style I-Line, Height 11 in, Width 6 in

9999 in stock

SKU: GRG2780827 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Molded Case Circuit Breaker”,”rank”:2,”value”:”Molded Case Circuit Breaker”},{“name”:”Series”,”normalizedValue”:”LA”,”rank”:3,”value”:”LA”},{“name”:”Amps”,”normalizedValue”:”400A”,”rank”:4,”value”:”400A”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”rank”:5,”value”:”3″},{“name”:”AC Voltage Rating”,”normalizedValue”:”600V AC”,”rank”:6,”value”:”600V AC”},{“name”:”Circuit Breaker Type”,”normalizedValue”:”Standard”,”rank”:7,”value”:”Standard”},{“name”:”Phase”,”normalizedValue”:”3″,”rank”:8,”value”:”3″},{“name”:”Circuit Breaker Actuator”,”normalizedValue”:”Toggle”,”rank”:9,”value”:”Toggle”},{“name”:”Circuit Breaker Mounting Style”,”normalizedValue”:”I-Line, Plug-On”,”rank”:10,”value”:”I-Line, Plug-On”},{“name”:”Max. AIR Rating”,”normalizedValue”:”42kA at 240V AC”,”rank”:11,”value”:”42kA at 240V AC”},{“name”:”Trip Type”,”normalizedValue”:”Thermal Magnetic”,”rank”:12,”value”:”Thermal Magnetic”},{“name”:”Instantaneous Trip”,”normalizedValue”:”Instantaneous”,”rank”:13,”value”:”Instantaneous”},{“name”:”Terminal Connection”,”normalizedValue”:”Lug, I-Line”,”rank”:14,”value”:”I-Line/Lug”},{“name”:”Phase Connection”,”normalizedValue”:”ABC”,”rank”:15,”value”:”ABC”},{“name”:”Frame Size”,”normalizedValue”:”400A, LA”,”rank”:16,”value”:”400A/LA”},{“name”:”Width”,”normalizedValue”:”6 in”,”rank”:17,”value”:”6 in”},{“name”:”Depth”,”normalizedValue”:”5.84 in”,”rank”:18,”value”:”5.84 in”},{“name”:”Height”,”normalizedValue”:”11 in”,”rank”:19,”value”:”11 in”},{“name”:”DC Voltage Rating”,”normalizedValue”:”250V DC”,”rank”:20,”value”:”250V DC”},{“name”:”High Amp Trip Setting”,”normalizedValue”:”4,000 A”,”value”:”4,000 A”},{“name”:”Max. Wire Size”,”normalizedValue”:”250 MCM, 600 MCM”,”value”:”250 MCM, 600 MCM”},{“name”:”Min. Wire Size”,”normalizedValue”:”1/0 AWG”,”value”:”1/0 AWG”},{“name”:”Low Amp Trip Setting”,”normalizedValue”:”2,000 A”,”value”:”2,000 A”},{“name”:”For Use With”,”normalizedValue”:”I Line Panelboards”,”value”:”I Line Panelboards”},{“name”:”Standards”,”normalizedValue”:”CSA, UL Listed”,”value”:”CSA, UL Listed”},{“name”:”Features”,”normalizedValue”:”Mercury Free; PVC Free”,”value”:”Mercury Free; PVC Free”},{“name”:”Application”,”normalizedValue”:”HACR rated Applications”,”value”:”HACR rated Applications”},{“name”:”Tightening Torque”,”normalizedValue”:”115.06 lbf.in (13 N.m) 0.07 to 0.47 in² (42 to 304 mm²) (AWG 1 to 600 kcmil); 115.06 lbf.in (13 N.m) 0.07 to 0.20 in² (42 to 127 mm²) (AWG 1 to 250 kcmil)”,”value”:”115.06 lbf.in (13 N.m) 0.07 to 0.47 in² (42 to 304 mm²) (AWG 1 to 600 kcmil); 115.06 lbf.in (13 N.m) 0.07 to 0.20 in² (42 to 127 mm²) (AWG 1 to 250 kcmil)”},{“name”:”Circuit Breaker Application”,”normalizedValue”:”HACR rated”,”value”:”HACR rated”},{“name”:”Wiring Configuration”,”normalizedValue”:”3-wire”,”value”:”3-wire”},{“name”:”Magnetic Tripping Current”,”normalizedValue”:”4,000 A”,”value”:”4000 A”},{“name”:”Certifications”,”normalizedValue”:”UL Listed; CSA”,”value”:”UL Listed; CSA”},{“name”:”Magnetic Hold Current”,”normalizedValue”:”2,000 A”,”value”:”2000 A”},{“name”:”Breaking Capacity Code”,”normalizedValue”:”A”,”value”:”A”},{“name”:”Terminal Identifier”,”normalizedValue”:”AL400LA”,”value”:”AL400LA”},{“name”:”Mounting”,”normalizedValue”:”Plug In Panelboard”,”value”:”Plug In Panelboard”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Molded Case Circuit Breaker, LA Series, 400A, 3 Pole, 600V AC, 42kA at 240V AC”