Description
[{“name”:”Item”,”normalizedValue”:”Molded Case Circuit Breaker”,”rank”:2,”value”:”Molded Case Circuit Breaker”},{“name”:”Series”,”normalizedValue”:”JJL”,”rank”:3,”value”:”JJL”},{“name”:”Amps”,”normalizedValue”:”225A”,”rank”:4,”value”:”225A”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”rank”:5,”value”:”3″},{“name”:”AC Voltage Rating”,”normalizedValue”:”600V AC”,”rank”:6,”value”:”600V AC”},{“name”:”Circuit Breaker Type”,”normalizedValue”:”Standard”,”rank”:7,”value”:”Standard”},{“name”:”Circuit Breaker Actuator”,”normalizedValue”:”Toggle”,”rank”:9,”value”:”Toggle”},{“name”:”Circuit Breaker Mounting Style”,”normalizedValue”:”Unit Mount”,”rank”:10,”value”:”Unit Mount”},{“name”:”Max. AIR Rating”,”normalizedValue”:”100kA at 240VAC”,”rank”:11,”value”:”100kA at 240VAC”},{“name”:”Trip Type”,”normalizedValue”:”Thermal Magnetic”,”rank”:12,”value”:”Thermal Magnetic”},{“name”:”Terminal Connection”,”normalizedValue”:”Line, Load Lug”,”rank”:14,”value”:”Line/Load Lug”},{“name”:”Phase Connection”,”normalizedValue”:”ABC”,”rank”:15,”value”:”ABC”},{“name”:”Frame Size”,”normalizedValue”:”250A, JJ”,”rank”:16,”value”:”250A/JJ”},{“name”:”Width”,”normalizedValue”:”4.12 in”,”rank”:17,”value”:”4.12 in”},{“name”:”Depth”,”normalizedValue”:”5 in”,”rank”:18,”value”:”5 in”},{“name”:”Height”,”normalizedValue”:”7.52 in”,”rank”:19,”value”:”7.52 in”},{“name”:”DC Voltage Rating”,”normalizedValue”:”250V DC”,”rank”:20,”value”:”250V DC”},{“name”:”Interrupt Rating”,”normalizedValue”:”65 kA at 220/240/480V AC, 35 kA at 380/440/415V AC, 18 kA at 500/525V AC, 20 kA at 250/500V DC, 100 kA at 240V AC, 25 kA at 600V AC”,”value”:”65 kA at 220/240/480V AC, 35 kA at 380/440/415V AC, 18 kA at 500/525V AC, 20 kA at 250/500V DC, 100 kA at 240V AC, 25 kA at 600V AC”},{“name”:”Max. Wire Size”,”normalizedValue”:”350 kcmil (Cu/Al)”,”value”:”350 kcmil (Cu/Al)”},{“name”:”Min. Wire Size”,”normalizedValue”:”3/0 AWG (Cu/Al)”,”value”:”3/0 AWG (Cu/Al)”},{“name”:”Features”,”normalizedValue”:”Mercury Free; PVC Free”,”value”:”Mercury Free; PVC Free”},{“name”:”High Amp Trip Setting”,”normalizedValue”:”2,250 A”,”value”:”2250 A”},{“name”:”Standards”,”normalizedValue”:”UL, CSA, NEMA, NOM, CE”,”value”:”UL, CSA, NEMA, NOM, CE”},{“name”:”Application”,”normalizedValue”:”HACR rated Applications; Distribution”,”value”:”HACR rated Applications; Distribution”},{“name”:”Terminal Identifier”,”normalizedValue”:”AL250JD”,”value”:”AL250JD”},{“name”:”Network Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Product Name”,”normalizedValue”:”PowerPact J”,”value”:”PowerPact J”},{“name”:”IP Degree Of Protection”,”normalizedValue”:”Front cover IP40″,”value”:”Front cover IP40″},{“name”:”Breaking Capacity Code”,”normalizedValue”:”J”,”value”:”J”},{“name”:”Continuous Current Rating”,”normalizedValue”:”0.8″,”value”:”0.8″},{“name”:”Power Wire Stripping Length”,”normalizedValue”:”0.98 in”,”value”:”0.98 in (25 mm)”},{“name”:”Tightening Torque”,”normalizedValue”:”221.27 lbf.in (25 N.m) 0.15 to 0.29 in² (95 to 185 mm²) (AWG 3/0 to 350 kcmil)”,”value”:”221.27 lbf.in (25 N.m) 0.15 to 0.29 in² (95 to 185 mm²) (AWG 3/0 to 350 kcmil)”},{“name”:”Rated Impulse Withstand Voltage”,”normalizedValue”:”8 kV IEC 60947-2″,”value”:”8 kV IEC 60947-2″},{“name”:”Pollution Degree”,”normalizedValue”:”3 IEC 60947-1″,”value”:”3 IEC 60947-1″},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”750 V IEC 60947-2″,”value”:”750 V IEC 60947-2″},{“name”:”Utilisation Category”,”normalizedValue”:”Category A”,”value”:”Category A”},{“name”:”Product Certifications”,”normalizedValue”:”CSA, UL, NOM”,”value”:”UL; CSA; NOM”},{“name”:”AWG Gauge”,”normalizedValue”:”AWG 3/0 to 350 kcmil aluminium/copper terminals”,”value”:”AWG 3/0 to 350 kcmil aluminium/copper terminals”},{“name”:”Local Signalling”,”normalizedValue”:”Switched off (OFF) 1 trip indicator green)”,”value”:”Switched off (OFF) 1 trip indicator green)”},{“name”:”Number Of Slots”,”normalizedValue”:”2 auxiliary switch OF plug-in); 1 alarm switch SD plug-in); 1 overcurrent trip switch SDE plug-in); 1 voltage release MN or MX plug-in)”,”value”:”2 auxiliary switch OF plug-in); 1 alarm switch SD plug-in); 1 overcurrent trip switch SDE plug-in); 1 voltage release MN or MX plug-in)”},{“name”:”Magnetic Hold Current”,”normalizedValue”:”1,125 A”,”value”:”1125 A”},{“name”:”Communication Interface”,”normalizedValue”:”Modbus, Ethernet”,”value”:”Modbus; Ethernet”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”600 V AC 50/60 Hz IEC 60947-3″,”value”:”600 V AC 50/60 Hz IEC 60947-3″},{“name”:”Quality Labels”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”Circuit Breaker Application”,”normalizedValue”:”HACR rated”,”value”:”HACR rated”},{“name”:”Rated Service Breaking Capacity”,”normalizedValue”:”65 kA 220/240 V AC 50/60 Hz IEC 60947-2; 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2; 18 kA 500/525 V AC 50/60 Hz IEC 60947-2; 20 kA 250 V DC IEC 60947-2; 20 kA 500 V DC IEC 60947-2″,”value”:”65 kA 220/240 V AC 50/60 Hz IEC 60947-2; 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2; 18 kA 500/525 V AC 50/60 Hz IEC 60947-2; 20 kA 250 V DC IEC 60947-2; 20 kA 500 V DC IEC 60947-2″},{“name”:”Protection Type”,”normalizedValue”:”Overload protection; Short-circuit protection”,”value”:”Overload protection; Short-circuit protection”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-58 to 185°F”,”value”:”-58 to 185°F (-50 to 85°C)”},{“name”:”Device Application”,”normalizedValue”:”Distribution”,”value”:”Distribution”},{“name”:”Suitability For Isolation”,”normalizedValue”:”Yes IEC 60947-2″,”value”:”Yes IEC 60947-2″},{“name”:”Long Time Pick-Up Adjustment Range”,”normalizedValue”:”0.25 to 1 x In”,”value”:”0.25 to 1 x In”},{“name”:”Operating Altitude”,”normalizedValue”:”Less than 6561.68 ft (2000 m) without derating; 5000 m with derating”,”value”:”Less than 6561.68 ft (2000 m) without derating; 5000 m with derating”},{“name”:”Breaking Capacity”,”normalizedValue”:”100 kA 240 V AC 50/60 Hz UL 489; 65 kA 480 V AC 50/60 Hz UL 489; 25 kA 600 V AC 50/60 Hz UL 489; 20 kA 250 V DC UL 489″,”value”:”100 kA 240 V AC 50/60 Hz UL 489; 65 kA 480 V AC 50/60 Hz UL 489; 25 kA 600 V AC 50/60 Hz UL 489; 20 kA 250 V DC UL 489″},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”28 to 158°F (-2 to 70°C)”,”value”:”28 to 158°F (-2 to 70°C)”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.