Molded Case Circuit Breaker, JGL Series, 175A, 3 Pole, 600V AC, 65kA at 240V AC

$2630,99

Molded Case Circuit Breaker, 175 A Amps, AC Voltage Rating 600V AC, Max. AIR Rating 25kA at 240V AC, For Use With I Line Panelboards, Series JG, High Amp Trip Setting 1,750 A, Low Amp Trip Setting 875 A, Circuit Breaker Type Standard, Number of Poles 3, DC Voltage Rating 500V DC, Terminal Connection Line/Load Lug, Trip Type Thermal Magnetic, Phase Three, Instantaneous Trip Instantaneous, Phase Connection ABC, Frame Size 250A/JG, Circuit Breaker Mounting Style Free Standing, Height 7.52 in

Out of stock

SKU: GRG2430872 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Molded Case Circuit Breaker”,”rank”:2,”value”:”Molded Case Circuit Breaker”},{“name”:”Series”,”normalizedValue”:”JGL”,”rank”:3,”value”:”JGL”},{“name”:”Amps”,”normalizedValue”:”175A”,”rank”:4,”value”:”175A”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”rank”:5,”value”:”3″},{“name”:”AC Voltage Rating”,”normalizedValue”:”600V AC”,”rank”:6,”value”:”600V AC”},{“name”:”Circuit Breaker Type”,”normalizedValue”:”Standard”,”rank”:7,”value”:”Standard”},{“name”:”Phase”,”normalizedValue”:”3″,”rank”:8,”value”:”3″},{“name”:”Circuit Breaker Actuator”,”normalizedValue”:”Toggle”,”rank”:9,”value”:”Toggle”},{“name”:”Circuit Breaker Mounting Style”,”normalizedValue”:”Unit Mount”,”rank”:10,”value”:”Unit Mount”},{“name”:”Max. AIR Rating”,”normalizedValue”:”65kA at 240V AC”,”rank”:11,”value”:”65kA at 240V AC”},{“name”:”Trip Type”,”normalizedValue”:”Thermal Magnetic”,”rank”:12,”value”:”Thermal Magnetic”},{“name”:”Instantaneous Trip”,”normalizedValue”:”Instantaneous”,”rank”:13,”value”:”Instantaneous”},{“name”:”Terminal Connection”,”normalizedValue”:”Line, Load Lug”,”rank”:14,”value”:”Line/Load Lug”},{“name”:”Phase Connection”,”normalizedValue”:”ABC”,”rank”:15,”value”:”ABC”},{“name”:”Frame Size”,”normalizedValue”:”250A, JG”,”rank”:16,”value”:”250A/JG”},{“name”:”Width”,”normalizedValue”:”4.12 in”,”rank”:17,”value”:”4.12 in”},{“name”:”Depth”,”normalizedValue”:”5 in”,”rank”:18,”value”:”5 in”},{“name”:”Height”,”normalizedValue”:”7.52 in”,”rank”:19,”value”:”7.52 in”},{“name”:”DC Voltage Rating”,”normalizedValue”:”250/500V DC”,”rank”:20,”value”:”250/500V DC”},{“name”:”Standards”,”normalizedValue”:”CCC, CE, CSA, IEC, UL Listed”,”value”:”CCC, CE, CSA, IEC, UL Listed”},{“name”:”High Amp Trip Setting”,”normalizedValue”:”1,750 A”,”value”:”1,750 A”},{“name”:”Low Amp Trip Setting”,”normalizedValue”:”875 A”,”value”:”875 A”},{“name”:”Max. Wire Size”,”normalizedValue”:”4 AWG”,”value”:”4 AWG”},{“name”:”For Use With”,”normalizedValue”:”I Line Panelboards”,”value”:”I Line Panelboards”},{“name”:”Min. Wire Size”,”normalizedValue”:”4 AWG”,”value”:”4 AWG”},{“name”:”Interrupt Rating”,”normalizedValue”:”65 kA at 220/240V AC, 35 kA at 380/440/415/480V AC, 18 kA at 500/525/600V AC, 20 kA at 250/500V DC”,”value”:”65 kA at 220/240V AC, 35 kA at 380/440/415/480V AC, 18 kA at 500/525/600V AC, 20 kA at 250/500V DC”},{“name”:”Application”,”normalizedValue”:”HACR rated Applications; Distribution”,”value”:”HACR rated Applications; Distribution”},{“name”:”Features”,”normalizedValue”:”Mercury Free; PVC Free”,”value”:”Mercury Free; PVC Free”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-58 to 185°F”,”value”:”-58 to 185°F (-50 to 85°C)”},{“name”:”Pollution Degree”,”normalizedValue”:”3 IEC 60947-1″,”value”:”3 IEC 60947-1″},{“name”:”Communication Interface”,”normalizedValue”:”Modbus, Ethernet”,”value”:”Modbus; Ethernet”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”28 to 158°F (-2 to 70°C)”,”value”:”28 to 158°F (-2 to 70°C)”},{“name”:”Utilisation Category”,”normalizedValue”:”Category A”,”value”:”Category A”},{“name”:”Breaking Capacity”,”normalizedValue”:”65 kA 240 V AC 50/60 Hz UL 489; 35 kA 480 V AC 50/60 Hz UL 489; 18 kA 600 V AC 50/60 Hz UL 489; 20 kA 250 V DC UL 489; 20 kA 500 V DC UL 489″,”value”:”65 kA 240 V AC 50/60 Hz UL 489; 35 kA 480 V AC 50/60 Hz UL 489; 18 kA 600 V AC 50/60 Hz UL 489; 20 kA 250 V DC UL 489; 20 kA 500 V DC UL 489″},{“name”:”Suitability For Isolation”,”normalizedValue”:”Yes IEC 60947-2″,”value”:”Yes IEC 60947-2″},{“name”:”Breaking Capacity Code”,”normalizedValue”:”G”,”value”:”G”},{“name”:”Magnetic Tripping Current”,”normalizedValue”:”1,750 A”,”value”:”1750 A”},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”750 V IEC 60947-2″,”value”:”750 V IEC 60947-2″},{“name”:”AWG Gauge”,”normalizedValue”:”AWG 4 to AWG 4/0 aluminium/copper terminal”,”value”:”AWG 4 to AWG 4/0 aluminium/copper terminal”},{“name”:”Power Wire Stripping Length”,”normalizedValue”:”0.98 in”,”value”:”0.98 in (25 mm)”},{“name”:”Device Application”,”normalizedValue”:”Distribution”,”value”:”Distribution”},{“name”:”Continuous Current Rating”,”normalizedValue”:”0.8″,”value”:”0.8″},{“name”:”Circuit Breaker Application”,”normalizedValue”:”HACR rated”,”value”:”HACR rated”},{“name”:”Quality Labels”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”Mounting Height”,”normalizedValue”:”4-1/2 in”,”value”:”4.5 in (114.30 mm)”},{“name”:”Rated Impulse Withstand Voltage”,”normalizedValue”:”8 kV IEC 60947-2″,”value”:”8 kV IEC 60947-2″},{“name”:”Terminal Identifier”,”normalizedValue”:”AL175JD”,”value”:”AL175JD”},{“name”:”Local Signalling”,”normalizedValue”:”Switched off (OFF) 1 trip indicator green)”,”value”:”Switched off (OFF) 1 trip indicator green)”},{“name”:”Network Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Tightening Torque”,”normalizedValue”:”221.27 lbf.in (25 N.m) 0.04 to 0.15 in² (25 to 95 mm²) (AWG 4 to AWG 4/0)”,”value”:”221.27 lbf.in (25 N.m) 0.04 to 0.15 in² (25 to 95 mm²) (AWG 4 to AWG 4/0)”},{“name”:”Product Name”,”normalizedValue”:”PowerPact J”,”value”:”PowerPact J”},{“name”:”Long Time Pick-Up Adjustment Range”,”normalizedValue”:”0.25 to 1 x In”,”value”:”0.25 to 1 x In”},{“name”:”Product Certifications”,”normalizedValue”:”CSA, UL, NOM”,”value”:”UL; CSA; NOM”},{“name”:”Protection Type”,”normalizedValue”:”Overload protection; Short-circuit protection”,”value”:”Overload protection; Short-circuit protection”},{“name”:”Number Of Slots”,”normalizedValue”:”2 auxiliary switch OF plug-in); 1 alarm switch SD plug-in); 1 overcurrent trip switch SDE plug-in); 1 voltage release MN or MX plug-in)”,”value”:”2 auxiliary switch OF plug-in); 1 alarm switch SD plug-in); 1 overcurrent trip switch SDE plug-in); 1 voltage release MN or MX plug-in)”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”600 V AC 50/60 Hz IEC 60947-3″,”value”:”600 V AC 50/60 Hz IEC 60947-3″},{“name”:”Rated Service Breaking Capacity”,”normalizedValue”:”65 kA 220/240 V AC 50/60 Hz IEC 60947-2; 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2; 18 kA 500/525 V AC 50/60 Hz IEC 60947-2; 20 kA 250 V DC IEC 60947-2; 20 kA 500 V DC IEC 60947-2″,”value”:”65 kA 220/240 V AC 50/60 Hz IEC 60947-2; 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2; 18 kA 500/525 V AC 50/60 Hz IEC 60947-2; 20 kA 250 V DC IEC 60947-2; 20 kA 500 V DC IEC 60947-2″},{“name”:”Operating Altitude”,”normalizedValue”:”Less than 6561.68 ft (2000 m) without derating; 5000 m with derating”,”value”:”Less than 6561.68 ft (2000 m) without derating; 5000 m with derating”},{“name”:”IP Degree Of Protection”,”normalizedValue”:”Front cover IP40″,”value”:”Front cover IP40″},{“name”:”Mounting”,”normalizedValue”:”Free Standing”,”value”:”Free Standing”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Molded Case Circuit Breaker, JGL Series, 175A, 3 Pole, 600V AC, 65kA at 240V AC”