Molded Case Circuit Breaker, HGA Series, 25A, 3 Pole, 600V AC, 65kA at 240V AC

$1137,99

Molded Case Circuit Breaker, 25 A Amps, AC Voltage Rating 600V AC, Max. AIR Rating 65kA at 240V AC, For Use With I Line Panelboards, Series HG, High Amp Trip Setting 750 A, Low Amp Trip Setting 350 A, Circuit Breaker Type Standard, Number of Poles 3, DC Voltage Rating 250V DC, Terminal Connection Lug, Trip Type Thermal Magnetic, Phase Three, Instantaneous Trip Fixed, Phase Connection ABC, Frame Size 150A/HG, Circuit Breaker Mounting Style I-Line, Height 9.73 in, Width 4.48 in, Depth 4.8 in

9999 in stock

SKU: GRG0662654 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Molded Case Circuit Breaker”,”rank”:2,”value”:”Molded Case Circuit Breaker”},{“name”:”Series”,”normalizedValue”:”HGA”,”rank”:3,”value”:”HGA”},{“name”:”Amps”,”normalizedValue”:”25A”,”rank”:4,”value”:”25A”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”rank”:5,”value”:”3″},{“name”:”AC Voltage Rating”,”normalizedValue”:”600V AC”,”rank”:6,”value”:”600V AC”},{“name”:”Circuit Breaker Type”,”normalizedValue”:”Standard”,”rank”:7,”value”:”Standard”},{“name”:”Phase”,”normalizedValue”:”3″,”rank”:8,”value”:”3″},{“name”:”Circuit Breaker Actuator”,”normalizedValue”:”Toggle”,”rank”:9,”value”:”Toggle”},{“name”:”Circuit Breaker Mounting Style”,”normalizedValue”:”I-Line”,”rank”:10,”value”:”I-Line”},{“name”:”Max. AIR Rating”,”normalizedValue”:”65kA at 240V AC”,”rank”:11,”value”:”65kA at 240V AC”},{“name”:”Trip Type”,”normalizedValue”:”Thermal Magnetic”,”rank”:12,”value”:”Thermal Magnetic”},{“name”:”Instantaneous Trip”,”normalizedValue”:”Fixed”,”rank”:13,”value”:”Fixed”},{“name”:”Terminal Connection”,”normalizedValue”:”Lug, I-Line”,”rank”:14,”value”:”I-Line, Lug”},{“name”:”Phase Connection”,”normalizedValue”:”ABC”,”rank”:15,”value”:”ABC”},{“name”:”Frame Size”,”normalizedValue”:”150A, HG”,”rank”:16,”value”:”150A/HG”},{“name”:”Width”,”normalizedValue”:”4.12 in”,”rank”:17,”value”:”4.12 in”},{“name”:”Depth”,”normalizedValue”:”4.36 in”,”rank”:18,”value”:”4.36 in”},{“name”:”Height”,”normalizedValue”:”6.4 in”,”rank”:19,”value”:”6.4 in”},{“name”:”DC Voltage Rating”,”normalizedValue”:”250/500V DC”,”rank”:20,”value”:”250/500V DC”},{“name”:”High Amp Trip Setting”,”normalizedValue”:”750 A”,”value”:”750 A”},{“name”:”Low Amp Trip Setting”,”normalizedValue”:”350 A”,”value”:”350 A”},{“name”:”Standards”,”normalizedValue”:”CE, CSA, IEC, UL listed”,”value”:”CE, CSA, IEC, UL listed”},{“name”:”Min. Wire Size”,”normalizedValue”:”14 AWG”,”value”:”14 AWG”},{“name”:”Max. Wire Size”,”normalizedValue”:”3 AWG”,”value”:”3 AWG”},{“name”:”For Use With”,”normalizedValue”:”I Line Panelboards”,”value”:”I Line Panelboards”},{“name”:”Interrupt Rating”,”normalizedValue”:”65 kA at 220/240V AC, 35 kA at 380/440/415/480V AC, 18 kA at 500/525/600V AC, 20 kA at 250/500V DC”,”value”:”65 kA at 220/240V AC, 35 kA at 380/440/415/480V AC, 18 kA at 500/525/600V AC, 20 kA at 250/500V DC”},{“name”:”Color”,”normalizedValue”:”Black”,”value”:”Black”},{“name”:”Features”,”normalizedValue”:”Mercury Free; PVC Free”,”value”:”Mercury Free; PVC Free”},{“name”:”Application”,”normalizedValue”:”HACR rated Applications; Distribution”,”value”:”HACR rated Applications; Distribution”},{“name”:”Max. Operating Temp.”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Mounting”,”normalizedValue”:”Plug In Panelboard”,”value”:”Plug In Panelboard”},{“name”:”Quality Labels”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”Protected Poles Description”,”normalizedValue”:”3t”,”value”:”3t”},{“name”:”Operating Altitude”,”normalizedValue”:”Less than 6561.68 ft (2000 m) without derating; 5000 m with derating”,”value”:”Less than 6561.68 ft (2000 m) without derating; 5000 m with derating”},{“name”:”Circuit Breaker Application”,”normalizedValue”:”HACR rated”,”value”:”HACR rated”},{“name”:”Rated Service Breaking Capacity”,”normalizedValue”:”65 kA 220/240 V AC 50/60 Hz IEC 60947-2; 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2; 18 kA 500/525 V AC 50/60 Hz IEC 60947-2; 20 kA 250 V DC IEC 60947-2; 20 kA 500 V DC IEC 60947-2″,”value”:”65 kA 220/240 V AC 50/60 Hz IEC 60947-2; 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2; 18 kA 500/525 V AC 50/60 Hz IEC 60947-2; 20 kA 250 V DC IEC 60947-2; 20 kA 500 V DC IEC 60947-2″},{“name”:”Product Name”,”normalizedValue”:”PowerPact H”,”value”:”PowerPact H”},{“name”:”Network Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Breaking Capacity”,”normalizedValue”:”65 kA 240 V AC 50/60 Hz UL 489; 35 kA 480 V AC 50/60 Hz UL 489; 18 kA 600 V AC 50/60 Hz UL 489; 20 kA 250 V DC UL 489; 20 kA 500 V DC UL 489″,”value”:”65 kA 240 V AC 50/60 Hz UL 489; 35 kA 480 V AC 50/60 Hz UL 489; 18 kA 600 V AC 50/60 Hz UL 489; 20 kA 250 V DC UL 489; 20 kA 500 V DC UL 489″},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”750 V IEC 60947-2″,”value”:”750 V IEC 60947-2″},{“name”:”Pollution Degree”,”normalizedValue”:”3 IEC 60947-1″,”value”:”3 IEC 60947-1″},{“name”:”Utilisation Category”,”normalizedValue”:”Category A”,”value”:”Category A”},{“name”:”Power Wire Stripping Length”,”normalizedValue”:”0.63 in”,”value”:”0.63 in (16 mm)”},{“name”:”Tightening Torque”,”normalizedValue”:”44.25 lbf.in (5 N.m) 0.00 to 0.01 in² (2.5 to 6 mm²) (AWG 14 to AWG 10); 123.91 lbf.in (14 N.m) 0.02 to 0.15 in² (10 to 95 mm²) (AWG 8 to AWG 3/0)”,”value”:”44.25 lbf.in (5 N.m) 0.00 to 0.01 in² (2.5 to 6 mm²) (AWG 14 to AWG 10); 123.91 lbf.in (14 N.m) 0.02 to 0.15 in² (10 to 95 mm²) (AWG 8 to AWG 3/0)”},{“name”:”Number Of Slots”,”normalizedValue”:”2 auxiliary switch OF plug-in); 1 alarm switch SD plug-in); 1 overcurrent trip switch SDE plug-in); 1 voltage release MN or MX plug-in)”,”value”:”2 auxiliary switch OF plug-in); 1 alarm switch SD plug-in); 1 overcurrent trip switch SDE plug-in); 1 voltage release MN or MX plug-in)”},{“name”:”AWG Gauge”,”normalizedValue”:”AWG 14 to AWG 3/0 aluminium/copper terminal”,”value”:”AWG 14 to AWG 3/0 aluminium/copper terminal”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”690 V AC 50/60 Hz IEC 60947-3″,”value”:”690 V AC 50/60 Hz IEC 60947-3″},{“name”:”Continuous Current Rating”,”normalizedValue”:”0.8″,”value”:”0.8″},{“name”:”Local Signalling”,”normalizedValue”:”Switched off (OFF) 1 trip indicator green)”,”value”:”Switched off (OFF) 1 trip indicator green)”},{“name”:”Product Certifications”,”normalizedValue”:”CSA, UL, NOM”,”value”:”UL; CSA; NOM”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”28 to 158°F (-2 to 70°C)”,”value”:”28 to 158°F (-2 to 70°C)”},{“name”:”Device Application”,”normalizedValue”:”Distribution”,”value”:”Distribution”},{“name”:”Terminal Identifier”,”normalizedValue”:”AL150HD”,”value”:”AL150HD”},{“name”:”Mounting Height”,”normalizedValue”:”4-1/2 in”,”value”:”4.5 in (114.30 mm)”},{“name”:”Communication Interface”,”normalizedValue”:”Modbus, Ethernet”,”value”:”Modbus; Ethernet”},{“name”:”Rated Impulse Withstand Voltage”,”normalizedValue”:”8 kV IEC 60947-2″,”value”:”8 kV IEC 60947-2″},{“name”:”IP Degree Of Protection”,”normalizedValue”:”Front cover IP40 IEC 60529″,”value”:”Front cover IP40 IEC 60529″},{“name”:”Breaking Capacity Code”,”normalizedValue”:”G”,”value”:”G”},{“name”:”Suitability For Isolation”,”normalizedValue”:”Yes IEC 60947-2″,”value”:”Yes IEC 60947-2″},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-58 to 185°F”,”value”:”-58 to 185°F (-50 to 85°C)”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Molded Case Circuit Breaker, HGA Series, 25A, 3 Pole, 600V AC, 65kA at 240V AC”