Molded Case Circuit Breaker, HFD Series, 30A, 1 Pole, 277V AC, 100kA at 240V AC

$676,58

Molded Case Circuit Breaker, 30 A Amps, AC Voltage Rating 277V AC, Max. AIR Rating 100kA at 240V AC, For Use With Allen Bradley MCC, Eaton MCC Eaton, Rockwell Automation Enclosed Control, Switchboard, Westinghouse, Series HFD, High Amp Trip Setting 150 A, Low Amp Trip Setting 15 A, Circuit Breaker Type Standard, Number of Poles 1, DC Voltage Rating 125V DC, Terminal Connection Load Side Lug, Trip Type Thermal Magnetic, Phase Single, Instantaneous Trip Fixed, Phase Connection AB

9999 in stock

SKU: GRG3731099 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Molded Case Circuit Breaker”,”rank”:2,”value”:”Molded Case Circuit Breaker”},{“name”:”Series”,”normalizedValue”:”HFD”,”rank”:3,”value”:”HFD”},{“name”:”Amps”,”normalizedValue”:”30A”,”rank”:4,”value”:”30A”},{“name”:”Number of Poles”,”normalizedValue”:”1″,”rank”:5,”value”:”1″},{“name”:”AC Voltage Rating”,”normalizedValue”:”277V AC”,”rank”:6,”value”:”277V AC”},{“name”:”Circuit Breaker Type”,”normalizedValue”:”Standard”,”rank”:7,”value”:”Standard”},{“name”:”Phase”,”normalizedValue”:”1″,”rank”:8,”value”:”1″},{“name”:”Circuit Breaker Actuator”,”normalizedValue”:”Toggle”,”rank”:9,”value”:”Toggle”},{“name”:”Circuit Breaker Mounting Style”,”normalizedValue”:”Free Standing”,”rank”:10,”value”:”Free Standing”},{“name”:”Max. AIR Rating”,”normalizedValue”:”100kA at 240V AC”,”rank”:11,”value”:”100kA at 240V AC”},{“name”:”Trip Type”,”normalizedValue”:”Thermal Magnetic”,”rank”:12,”value”:”Thermal Magnetic”},{“name”:”Instantaneous Trip”,”normalizedValue”:”Fixed”,”rank”:13,”value”:”Fixed”},{“name”:”Terminal Connection”,”normalizedValue”:”Load Side Lug”,”rank”:14,”value”:”Load Side Lug”},{“name”:”Phase Connection”,”normalizedValue”:”AB”,”rank”:15,”value”:”AB”},{“name”:”Frame Size”,”normalizedValue”:”225A, F”,”rank”:16,”value”:”225A/F”},{“name”:”Width”,”normalizedValue”:”1.38 in”,”rank”:17,”value”:”1.38 in”},{“name”:”Depth”,”normalizedValue”:”3.38 in”,”rank”:18,”value”:”3.38 in”},{“name”:”Height”,”normalizedValue”:”3.38 in”,”rank”:19,”value”:”3.38 in”},{“name”:”DC Voltage Rating”,”normalizedValue”:”125V DC”,”rank”:20,”value”:”125V DC”},{“name”:”Standards”,”normalizedValue”:”CSA Certified, IEC Rated, UL Listed”,”value”:”CSA Certified, IEC Rated, UL Listed”},{“name”:”Max. Wire Size”,”normalizedValue”:”1/0 AWG”,”value”:”1/0 AWG”},{“name”:”For Use With”,”normalizedValue”:”Allen Bradley MCC, Eaton MCC Eaton, Rockwell Automation Enclosed Control, Switchboard, Westinghouse”,”value”:”Allen Bradley MCC, Eaton MCC Eaton, Rockwell Automation Enclosed Control, Switchboard, Westinghouse”},{“name”:”Low Amp Trip Setting”,”normalizedValue”:”15 A”,”value”:”15 A”},{“name”:”Min. Wire Size”,”normalizedValue”:”14 AWG”,”value”:”14 AWG”},{“name”:”High Amp Trip Setting”,”normalizedValue”:”150 A”,”value”:”150 A”},{“name”:”Frame Type”,”normalizedValue”:”Complete Breaker”,”value”:”Complete Breaker”},{“name”:”Interrupt Rating”,”normalizedValue”:”100 kA at 240V AC”,”value”:”100 kA at 240V AC”},{“name”:”Min. Operating Temp.”,”normalizedValue”:”-4 deg F”,”value”:”-4 Degrees F”},{“name”:”Max. Operating Temp.”,”normalizedValue”:”158 deg F”,”value”:”158 Degrees F”},{“name”:”Frame”,”normalizedValue”:”F”,”value”:”F”},{“name”:”Product Name”,”normalizedValue”:”Eaton Series C complete molded case circuit breaker”,”value”:”Eaton Series C complete molded case circuit breaker”},{“name”:”Frequency Rating”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Certifications”,”normalizedValue”:”UL Listed”,”value”:”UL Listed”},{“name”:”Mounting”,”normalizedValue”:”Free Standing”,”value”:”Free Standing”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Dominican Republic”,”value”:”Dominican Republic”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Molded Case Circuit Breaker, HFD Series, 30A, 1 Pole, 277V AC, 100kA at 240V AC”