Description
[{“name”:”Item”,”normalizedValue”:”Molded Case Circuit Breaker”,”rank”:1,”value”:”Molded Case Circuit Breaker”},{“name”:”Amps”,”normalizedValue”:”175″,”rank”:2,”value”:”175 A”},{“name”:”AC Voltage Rating”,”normalizedValue”:”600V AC”,”rank”:3,”value”:”600V AC”},{“name”:”DC Voltage Rating”,”normalizedValue”:”250V DC”,”rank”:4,”value”:”250V DC”},{“name”:”Max. AIR Rating”,”normalizedValue”:”25kA at 240V AC”,”rank”:6,”value”:”25kA at 240V AC”},{“name”:”Terminal Connection”,”normalizedValue”:”Load Lug, Line”,”rank”:7,”value”:”Line/Load Lug”},{“name”:”Series”,”normalizedValue”:”JD”,”rank”:8,”value”:”JD”},{“name”:”Number of Poles”,”normalizedValue”:”2″,”rank”:9,”value”:”2″},{“name”:”Circuit Breaker Actuator”,”normalizedValue”:”Toggle”,”rank”:10,”value”:”Toggle”},{“name”:”Frame Size”,”normalizedValue”:”250A, JD”,”rank”:12,”value”:”250A/JD”},{“name”:”Circuit Breaker Mounting Style”,”normalizedValue”:”Free Standing”,”rank”:13,”value”:”Free Standing”},{“name”:”Circuit Breaker Type”,”normalizedValue”:”Standard”,”rank”:14,”value”:”Standard”},{“name”:”Standards”,”normalizedValue”:”BS, CCC, CE Marked, CEI, CSA Certified, Federal Specification W-C-375B/GEN, HACR, HID, IEC, NEMA, NMX, NOM, SWD, UL Listed, UNE, UTE, VDE”,”rank”:15,”value”:”BS, CCC, CE Marked, CEI, CSA Certified, Federal Specification W-C-375B/GEN, HACR, HID, IEC, NEMA, NMX, NOM, SWD, UL Listed, UNE, UTE, VDE”},{“name”:”Trip Type”,”normalizedValue”:”Thermal Magnetic”,”value”:”Thermal Magnetic”},{“name”:”Max. Wire Size”,”normalizedValue”:”4/0 AWG”,”value”:”4/0 AWG”},{“name”:”Mounting”,”normalizedValue”:”Free Standing”,”value”:”Free Standing”},{“name”:”Depth”,”normalizedValue”:”5 in”,”value”:”5 in”},{“name”:”Instantaneous Trip”,”normalizedValue”:”Adjustable”,”value”:”Adjustable”},{“name”:”Width”,”normalizedValue”:”2.7 in”,”value”:”2.7 in”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Phase Connection”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”High Amp Trip Setting”,”normalizedValue”:”1,750 A”,”value”:”1,750 A”},{“name”:”Min. Wire Size”,”normalizedValue”:”4 AWG”,”value”:”4 AWG”},{“name”:”Height”,”normalizedValue”:”7-1/2 in”,”value”:”7.5 in”},{“name”:”Low Amp Trip Setting”,”normalizedValue”:”875 A”,”value”:”875 A”},{“name”:”Interrupt Rating”,”normalizedValue”:”25 kA at 220/240V AC, 18 kA at 380/440/415/480V AC, 14 kA at 500/525/600V AC, 20 kA at 250/500V DC”,”value”:”25 kA at 220/240V AC, 18 kA at 380/440/415/480V AC, 14 kA at 500/525/600V AC, 20 kA at 250/500V DC”},{“name”:”Features”,”normalizedValue”:”Mercury Free, PVC Free”,”value”:”Mercury Free, PVC Free”},{“name”:”Application”,”normalizedValue”:”HACR rated Applications, Distribution”,”value”:”HACR rated Applications, Distribution”},{“name”:”Tightening Torque”,”normalizedValue”:”221.27 lbf.in (25 N.m) 0.04 to 0.15 in? (25 to 95 mm?) (AWG 4 to AWG 4/0)”,”value”:”221.27 lbf.in (25 N.m) 0.04 to 0.15 in? (25 to 95 mm?) (AWG 4 to AWG 4/0)”},{“name”:”Device Application”,”normalizedValue”:”Distribution”,”value”:”Distribution”},{“name”:”Trip Unit Technology”,”normalizedValue”:”Thermal-magnetic”,”value”:”Thermal-magnetic”},{“name”:”Operating Altitude”,”normalizedValue”:”Less than 6561.68 ft (2000 m) without derating, 5000 m with derating”,”value”:”Less than 6561.68 ft (2000 m) without derating, 5000 m with derating”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”600 V AC 50/60 Hz IEC 60947-3″,”value”:”600 V AC 50/60 Hz IEC 60947-3″},{“name”:”Circuit Breaker Application”,”normalizedValue”:”HACR rated”,”value”:”HACR rated”},{“name”:”Rated Impulse Withstand Voltage”,”normalizedValue”:”8 kV IEC 60947-2″,”value”:”8 kV IEC 60947-2″},{“name”:”Utilisation Category”,”normalizedValue”:”Category A”,”value”:”Category A”},{“name”:”Network Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Number Of Slots”,”normalizedValue”:”2 auxiliary switch OF plug-in), 1 alarm switch SD plug-in), 1 overcurrent trip switch SDE plug-in), 1 voltage release MN or MX plug-in)”,”value”:”2 auxiliary switch OF plug-in), 1 alarm switch SD plug-in), 1 overcurrent trip switch SDE plug-in), 1 voltage release MN or MX plug-in)”},{“name”:”IP Degree Of Protection”,”normalizedValue”:”Front cover IP40″,”value”:”Front cover IP40″},{“name”:”Power Wire Stripping Length”,”normalizedValue”:”0.98 in”,”value”:”0.98 in (25 mm)”},{“name”:”Rated Service Breaking Capacity”,”normalizedValue”:”25 kA 220/240 V AC 50/60 Hz IEC 60947-2, 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2, 14 kA 500/525 V AC 50/60 Hz IEC 60947-2, 20 kA 250 V DC IEC 60947-2, 20 kA 500 V DC IEC 60947-2″,”value”:”25 kA 220/240 V AC 50/60 Hz IEC 60947-2, 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2, 14 kA 500/525 V AC 50/60 Hz IEC 60947-2, 20 kA 250 V DC IEC 60947-2, 20 kA 500 V DC IEC 60947-2″},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”750 V IEC 60947-2″,”value”:”750 V IEC 60947-2″},{“name”:”Protection Type”,”normalizedValue”:”Overload protection, Short-circuit protection”,”value”:”Overload protection, Short-circuit protection”},{“name”:”Breaking Capacity”,”normalizedValue”:”25 kA 240 V AC 50/60 Hz UL 489, 18 kA 480 V AC 50/60 Hz, 14 kA 600 V AC 50/60 Hz, 20 kA 250 V DC”,”value”:”25 kA 240 V AC 50/60 Hz UL 489, 18 kA 480 V AC 50/60 Hz, 14 kA 600 V AC 50/60 Hz, 20 kA 250 V DC”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-58 to 185°F”,”value”:”-58 to 185°F (-50 to 85°C)”},{“name”:”Suitability For Isolation”,”normalizedValue”:”Yes IEC 60947-2″,”value”:”Yes IEC 60947-2″},{“name”:”Quality Labels”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”AWG Gauge”,”normalizedValue”:”AWG 4 to AWG 4/0 aluminium/copper terminal”,”value”:”AWG 4 to AWG 4/0 aluminium/copper terminal”},{“name”:”Magnetic Tripping Current”,”normalizedValue”:”1,750 A”,”value”:”1750 A”},{“name”:”Product Certifications”,”normalizedValue”:”CSA, UL, NOM”,”value”:”UL, CSA, NOM”},{“name”:”Local Signalling”,”normalizedValue”:”Switched off (OFF) 1 trip indicator green)”,”value”:”Switched off (OFF) 1 trip indicator green)”},{“name”:”Communication Interface”,”normalizedValue”:”Modbus, Ethernet”,”value”:”Modbus, Ethernet”},{“name”:”Pollution Degree”,”normalizedValue”:”3 IEC 60947-1″,”value”:”3 IEC 60947-1″},{“name”:”Mounting Mode”,”normalizedValue”:”Unit mount lug”,”value”:”Unit mount lug)”},{“name”:”Product Name”,”normalizedValue”:”PowerPact J”,”value”:”PowerPact J”},{“name”:”Continuous Current Rating”,”normalizedValue”:”0.8″,”value”:”0.8″},{“name”:”Electrical Connection”,”normalizedValue”:”Lugs, line, Lugs, load”,”value”:”Lugs, line, Lugs, load”},{“name”:”Breaking Capacity Code”,”normalizedValue”:”D”,”value”:”D”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”28 to 158°F (-2 to 70°C)”,”value”:”28 to 158°F (-2 to 70°C)”},{“name”:”Long Time Pick-Up Adjustment Range”,”normalizedValue”:”0.25 to 1 x In”,”value”:”0.25 to 1 x In”},{“name”:”Terminal Identifier”,”normalizedValue”:”AL175JD”,”value”:”AL175JD”},{“name”:”Mounting Support”,”normalizedValue”:”Lug”,”value”:”Lug”},{“name”:”Product Or Component Type”,”normalizedValue”:”Circuit breaker”,”value”:”Circuit breaker”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Multiple”,”value”:”Multiple”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.