Molded Case Circuit Breaker, 175 A, 240V AC, 2 Pole, I-Line Mounting Style, QD Series, SQUARE D, Mfr# QDA221752

$784,99

Molded Case Circuit Breaker, 175 A Amps, AC Voltage Rating 240V AC, Max. AIR Rating 25kA at 240V AC, For Use With I Line Panelboards, Series QD, High Amp Trip Setting 2,400 A, Low Amp Trip Setting 1,200 A, Circuit Breaker Type Standard, Number of Poles 2, DC Voltage Rating Not Rated, Terminal Connection Lug, Trip Type Thermal Magnetic, Phase Single, Instantaneous Trip Fixed, Phase Connection AC, Frame Size 250A/QD, Circuit Breaker Mounting Style I-Line, Height 6.47 in, Width 3 in, Depth 3.93 in

9999 in stock

SKU: GRG1808694 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Molded Case Circuit Breaker”,”rank”:1,”value”:”Molded Case Circuit Breaker”},{“name”:”Amps”,”normalizedValue”:”175″,”rank”:2,”value”:”175 A”},{“name”:”AC Voltage Rating”,”normalizedValue”:”240V AC”,”rank”:3,”value”:”240V AC”},{“name”:”DC Voltage Rating”,”normalizedValue”:”Not Rated”,”rank”:4,”value”:”Not Rated”},{“name”:”Max. AIR Rating”,”normalizedValue”:”25kA at 240V AC”,”rank”:6,”value”:”25kA at 240V AC”},{“name”:”Terminal Connection”,”normalizedValue”:”Lug”,”rank”:7,”value”:”Lug”},{“name”:”Series”,”normalizedValue”:”QD”,”rank”:8,”value”:”QD”},{“name”:”Number of Poles”,”normalizedValue”:”2″,”rank”:9,”value”:”2″},{“name”:”Circuit Breaker Actuator”,”normalizedValue”:”Toggle”,”rank”:10,”value”:”Toggle”},{“name”:”Frame Size”,”normalizedValue”:”250A, QD”,”rank”:12,”value”:”250A/QD”},{“name”:”Circuit Breaker Mounting Style”,”normalizedValue”:”I-Line”,”rank”:13,”value”:”I-Line”},{“name”:”Circuit Breaker Type”,”normalizedValue”:”Standard”,”rank”:14,”value”:”Standard”},{“name”:”Standards”,”normalizedValue”:”CE Marked, CSA Certified, IEC, UL Listed”,”rank”:15,”value”:”CE Marked, CSA Certified, IEC, UL Listed”},{“name”:”Max. Wire Size”,”normalizedValue”:”300 MCM”,”value”:”300 MCM”},{“name”:”Height”,”normalizedValue”:”6.47 in”,”value”:”6.47 in”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”High Amp Trip Setting”,”normalizedValue”:”2,400 A”,”value”:”2,400 A”},{“name”:”Instantaneous Trip”,”normalizedValue”:”Fixed”,”value”:”Fixed”},{“name”:”Phase Connection”,”normalizedValue”:”AC”,”value”:”AC”},{“name”:”Width”,”normalizedValue”:”3 in”,”value”:”3 in”},{“name”:”Depth”,”normalizedValue”:”3.93 in”,”value”:”3.93 in”},{“name”:”Low Amp Trip Setting”,”normalizedValue”:”1,200 A”,”value”:”1,200 A”},{“name”:”For Use With”,”normalizedValue”:”I Line Panelboards”,”value”:”I Line Panelboards”},{“name”:”Trip Type”,”normalizedValue”:”Thermal Magnetic”,”value”:”Thermal Magnetic”},{“name”:”Min. Wire Size”,”normalizedValue”:”4 AWG”,”value”:”4 AWG”},{“name”:”Mounting”,”normalizedValue”:”Plug In Panelboard”,”value”:”Plug In Panelboard”},{“name”:”Features”,”normalizedValue”:”Mercury Free, PVC Free”,”value”:”Mercury Free, PVC Free”},{“name”:”Interrupt Rating”,”normalizedValue”:”25 kA at 120/208/240V AC”,”value”:”25 kA at 120/208/240V AC”},{“name”:”Application”,”normalizedValue”:”HACR rated Applications, Distribution”,”value”:”HACR rated Applications, Distribution”},{“name”:”Breaking Capacity Code”,”normalizedValue”:”D”,”value”:”D”},{“name”:”Product Certifications”,”normalizedValue”:”CSA, UL, NOM”,”value”:”UL, CSA, NOM”},{“name”:”Continuous Current Rating”,”normalizedValue”:”0.8″,”value”:”0.8″},{“name”:”Mechanical Durability”,”normalizedValue”:”1000 cycles loaded, 5000 cycles no load”,”value”:”1000 cycles loaded, 5000 cycles no load”},{“name”:”Magnetic Hold Current”,”normalizedValue”:”1,200 A”,”value”:”1200 A”},{“name”:”Electrical Connection”,”normalizedValue”:”I-Line connection, line, Lugs, load”,”value”:”I-Line connection, line, Lugs, load”},{“name”:”Circuit Breaker Application”,”normalizedValue”:”HACR rated”,”value”:”HACR rated”},{“name”:”Magnetic Tripping Current”,”normalizedValue”:”2,400 A”,”value”:”2400 A”},{“name”:”Local Signalling”,”normalizedValue”:”1 trip indicator green)”,”value”:”1 trip indicator green)”},{“name”:”Power Wire Stripping Length”,”normalizedValue”:”0.87 in”,”value”:”0.87 in (22 mm)”},{“name”:”Product Or Component Type”,”normalizedValue”:”Circuit breaker”,”value”:”Circuit breaker”},{“name”:”Device Application”,”normalizedValue”:”Distribution”,”value”:”Distribution”},{“name”:”Rated Impulse Withstand Voltage”,”normalizedValue”:”8 kV UL”,”value”:”8 kV UL”},{“name”:”Trip Unit Technology”,”normalizedValue”:”Thermal-magnetic”,”value”:”Thermal-magnetic”},{“name”:”Breaking Capacity”,”normalizedValue”:”25 kA 120/208 V AC 50/60 Hz UL, 25 kA 240 V AC 50/60 Hz UL”,”value”:”25 kA 120/208 V AC 50/60 Hz UL, 25 kA 240 V AC 50/60 Hz UL”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”240 V AC 50/60 Hz UL”,”value”:”240 V AC 50/60 Hz UL”},{“name”:”Product Name”,”normalizedValue”:”PowerPact Q”,”value”:”PowerPact Q”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”104 to 158°F (40 to 70°C)”,”value”:”104 to 158°F (40 to 70°C)”},{“name”:”Mounting Mode”,”normalizedValue”:”I-Line bracket”,”value”:”I-Line bracket)”},{“name”:”Network Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Control Type”,”normalizedValue”:”Operating handle”,”value”:”Operating handle”},{“name”:”Mounting Support”,”normalizedValue”:”Bracket”,”value”:”Bracket”},{“name”:”Mounting Height”,”normalizedValue”:”3 in”,”value”:”3 in (76.20 mm)”},{“name”:”Tightening Torque”,”normalizedValue”:”247.82 lbf.in (28 N.m) 0.04 to 0.23 in? (25 to 150 mm?) (AWG 4 to 300 kcmil)”,”value”:”247.82 lbf.in (28 N.m) 0.04 to 0.23 in? (25 to 150 mm?) (AWG 4 to 300 kcmil)”},{“name”:”Utilisation Category”,”normalizedValue”:”Category A”,”value”:”Category A”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Molded Case Circuit Breaker, 175 A, 240V AC, 2 Pole, I-Line Mounting Style, QD Series, SQUARE D, Mfr# QDA221752”