Description
[{“name”:”Standards”,”normalizedValue”:”IEC 60947-7-3″,”value”:”IEC 60947-7-3″},{“name”:”Material”,”normalizedValue”:”Wemid”,”value”:”Wemid”},{“name”:”Voltage size C (UR)”,”normalizedValue”:”600 V”,”value”:”600 V”},{“name”:”Operating voltage, max.”,”normalizedValue”:”500 V”,”value”:”500 V”},{“name”:”Continuous operating temp., min.”,”normalizedValue”:”-50 deg C”,”value”:”-50 °C”},{“name”:”Conductor size Factory wiring min. (UR)”,”normalizedValue”:”22 AWG”,”value”:”22 AWG”},{“name”:”Power loss for short-circuit protection only for an individual arrangement”,”normalizedValue”:”4 W at 10 A @ 52°C”,”value”:”4 W at 10 A @ 52°C”},{“name”:”Storage temperature”,”normalizedValue”:”10 deg C”,”value”:”10°C…40°C”},{“name”:”Certificate No. (UR)”,”normalizedValue”:”E60693″,”value”:”E60693″},{“name”:”Tightening torque, min.”,”normalizedValue”:”0.8 N-m”,”value”:”0.8 Nm”},{“name”:”Number of Levels”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Type of mounting”,”normalizedValue”:”Snap-on”,”value”:”Snap-on”},{“name”:”Wire connection cross-section, solid core, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Wire connection cross-section, finely stranded, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Power loss for short-circuit protection only for a composite arrangement”,”normalizedValue”:”2.5 W at 2.5 A @ 62°C”,”value”:”2.5 W at 2.5 A @ 62°C”},{“name”:”Cartridge fuse”,”normalizedValue”:”6.3 x 32 mm (1/4 x 1 1/4\”)”,”value”:”6.3 x 32 mm (1/4 x 1 1/4\”)”},{“name”:”Connection cross-section, stranded, max.”,”normalizedValue”:”10 sq mm”,”value”:”10 mm²”},{“name”:”Wire cross section max. (CSA)”,”normalizedValue”:”6 AWG”,”value”:”6 AWG”},{“name”:”Continuous operating temp., max.”,”normalizedValue”:”120 deg C”,”value”:”120 °C”},{“name”:”Fuse holder (cartridge holder)”,”normalizedValue”:”Pivoting”,”value”:”Pivoting”},{“name”:”Wire connection cross section, finely stranded, two clampable wires, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Width (inches)”,”normalizedValue”:”0.469 in”,”value”:”0.469 inch”},{“name”:”Clamping range, min.”,”normalizedValue”:”0.5 sq mm”,”value”:”0.5 mm²”},{“name”:”Clamping range, max.”,”normalizedValue”:”10 sq mm”,”value”:”10 mm²”},{“name”:”Rated voltage to adjoining terminal”,”normalizedValue”:”500 V”,”value”:”500 V”},{“name”:”Connection direction”,”normalizedValue”:”on side”,”value”:”on side”},{“name”:”PE connection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Current at maximum wires”,”normalizedValue”:”6.3 A”,”value”:”6.3 A”},{“name”:”Connection cross-section, stranded, min.”,”normalizedValue”:”1.5 sq mm”,”value”:”1.5 mm²”},{“name”:”Rated current”,”normalizedValue”:”6.3 A”,”value”:”6.3 A”},{“name”:”Rail”,”normalizedValue”:”TS 35″,”value”:”TS 35″},{“name”:”End cover plate required”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Number of similar terminals”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Storage temperature, min.”,”normalizedValue”:”10 °C”,”value”:”10 °C”},{“name”:”Number of clamping points per level”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Voltage size B (CSA)”,”normalizedValue”:”150 V”,”value”:”150 V”},{“name”:”Clamping screw”,”normalizedValue”:”M 3.5″,”value”:”M 3.5″},{“name”:”Rated impulse withstand voltage”,”normalizedValue”:”6 kV”,”value”:”6 kV”},{“name”:”Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Stripping length”,”normalizedValue”:”12 mm”,”value”:”12 mm”},{“name”:”Torque level with DMS electric screwdriver”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Certificate No. (CSA)”,”normalizedValue”:”200,039 to 1,057,876″,”value”:”200039-1057876″},{“name”:”Tightening torque, max.”,”normalizedValue”:”1.6 N-m”,”value”:”1.6 Nm”},{“name”:”Type of voltage for indicator”,”normalizedValue”:”AC”,”value”:”AC”},{“name”:”Wire cross section min. (CSA)”,”normalizedValue”:”20 AWG”,”value”:”20 AWG”},{“name”:”Blade Size”,”normalizedValue”:”0.8 mm x 4 mm”,”value”:”0.8 x 4.0 mm”},{“name”:”Voltage size C (CSA)”,”normalizedValue”:”150 V”,”value”:”150 V”},{“name”:”Voltage size D (CSA)”,”normalizedValue”:”600 V”,”value”:”600 V”},{“name”:”Operating voltage for display, max.”,”normalizedValue”:”500 V”,”value”:”500 V”},{“name”:”Current size B (CSA)”,”normalizedValue”:”16 A”,”value”:”16 A”},{“name”:”Wire connection cross-section, solid core, max.”,”normalizedValue”:”10 sq mm”,”value”:”10 mm²”},{“name”:”Wire cross-section, finely stranded, two clampable wires, max.”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Conductor cross-section, flexible plus plastic collar DIN 46228/1, further connection, max.”,”normalizedValue”:”6 sq mm”,”value”:”6 mm²”},{“name”:”Approvals”,”normalizedValue”:”CE, CSA, DNV GL, EAC, LLOYDSREG, MARITREG, NEMKO, UR”,”value”:”CE, CSA, DNV GL, EAC, LLOYDSREG, MARITREG, NEMKO, UR”},{“name”:”Depth (inches)”,”normalizedValue”:”2.618 in”,”value”:”2.618 inch”},{“name”:”UL File Number Search”,”normalizedValue”:”E60693″,”value”:”E60693″},{“name”:”Wire connection cross section AWG, min.”,”normalizedValue”:”AWG 20″,”value”:”AWG 20″},{“name”:”Colour”,”normalizedValue”:”beige”,”value”:”dark beige”},{“name”:”Volume resistance according to IEC 60947-7-x”,”normalizedValue”:”0.78 milliohm”,”value”:”0.78 mΩ”},{“name”:”Display”,”normalizedValue”:”Without LED”,”value”:”Without LED”},{“name”:”Current size D (CSA)”,”normalizedValue”:”5 A”,”value”:”5A”},{“name”:”Conductor size Factory wiring max. (UR)”,”normalizedValue”:”8 AWG”,”value”:”8 AWG”},{“name”:”Wire connection cross section, finely stranded with wire-end ferrules DIN 46228/1, 2 clampable wires, max.”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Rated cross-section”,”normalizedValue”:”6 mm²”,”value”:”6 mm²”},{“name”:”Number of connections”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Number of potentials per tier”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Storage temperature, max.”,”normalizedValue”:”40 deg C”,”value”:”40 °C”},{“name”:”Depth including DIN rail”,”normalizedValue”:”67 mm”,”value”:”67 mm”},{“name”:”Conductor size Field wiring max. (UR)”,”normalizedValue”:”8 AWG”,”value”:”8 AWG”},{“name”:”Open sides”,”normalizedValue”:”right”,”value”:”right”},{“name”:”Wire connection cross section AWG, max.”,”normalizedValue”:”AWG 8″,”value”:”AWG 8″},{“name”:”Wire connection cross section, finely stranded with wire-end ferrules DIN 46228/1, 2 clampable wires, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Height (inches)”,”normalizedValue”:”2.362 in”,”value”:”2.362 inch”},{“name”:”Version”,”normalizedValue”:”Screw connection, Fuse isolator, for screwable cross-connection, One end without connector”,”value”:”Screw connection, Fuse isolator, for screwable cross-connection, One end without connector”},{“name”:”Current size C (CSA)”,”normalizedValue”:”16 A”,”value”:”16 A”},{“name”:”Type of connection”,”normalizedValue”:”Screw connection”,”value”:”Screw connection”},{“name”:”Gauge to IEC 60947-1″,”normalizedValue”:”A5″,”value”:”A5″},{“name”:”Current size C (UR)”,”normalizedValue”:”16 A”,”value”:”16 A”},{“name”:”PE function”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Rated voltage”,”normalizedValue”:”250 V”,”value”:”250 V”},{“name”:”Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.”,”normalizedValue”:”6 sq mm”,”value”:”6 mm²”},{“name”:”Power loss in accordance with IEC 60947-7-x”,”normalizedValue”:”1.31 W”,”value”:”1.31 W”},{“name”:”Conductor size Field wiring min. (UR)”,”normalizedValue”:”22 AWG”,”value”:”22 AWG”},{“name”:”Wire connection cross section, finely stranded, max.”,”normalizedValue”:”10 sq mm”,”value”:”10 mm²”},{“name”:”Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.”,”normalizedValue”:”0.5 sq mm”,”value”:”0.5 mm²”},{“name”:”Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max.”,”normalizedValue”:”6 sq mm”,”value”:”6 mm²”},{“name”:”Power loss for overload and short-circuit protection for a composite arrangement”,”normalizedValue”:”2.5 W at 2.5 A @ 30°C”,”value”:”2.5 W at 2.5 A @ 30°C”},{“name”:”UL 94 flammability rating”,”normalizedValue”:”V-0″,”value”:”V-0″},{“name”:”Power loss for overload and short-circuit protection for an individual arrangement”,”normalizedValue”:”2.5 W at 2.5 A @ 42°C”,”value”:”2.5 W at 2.5 A @ 42°C”},{“name”:”Pollution severity”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Number of potentials”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Czechia”,”value”:”Czechia”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.