Description
[{“name”:”Item”,”normalizedValue”:”Meter Main”,”rank”:2,”value”:”Meter Main”},{“name”:”Amps”,”normalizedValue”:”1A; 5A”,”rank”:5,”value”:”1A; 5A”},{“name”:”Height”,”normalizedValue”:”6.1 in”,”rank”:9,”value”:”6.1 in”},{“name”:”Width”,”normalizedValue”:”5 in”,”rank”:10,”value”:”5 in”},{“name”:”Depth”,”normalizedValue”:”72 mm”,”rank”:11,”value”:”72 mm”},{“name”:”Series”,”normalizedValue”:”MET”,”rank”:12,”value”:”MET”},{“name”:”Standards”,”normalizedValue”:”EN 50470-3 || EN 50470-1 || IEC 62053-22 || IEC 60529 || UL 61010-1 || IEC 62053-24 || IEC 61557-12 || ANSI C12.20; CE IEC 61010-1 || cULus UL 61010-1 || BTL; class 0.2S active energy IEC 62053-22″,”value”:”EN 50470-3 || EN 50470-1 || IEC 62053-22 || IEC 60529 || UL 61010-1 || IEC 62053-24 || IEC 61557-12 || ANSI C12.20; CE IEC 61010-1 || cULus UL 61010-1 || BTL; class 0.2S active energy IEC 62053-22″},{“name”:”Mounting Style”,”normalizedValue”:”Clip-on”,”value”:”Clip-on”},{“name”:”Weight”,”normalizedValue”:”450 g”,”value”:”450 g”},{“name”:”Web Services”,”normalizedValue”:”diagnostic via predefined web pages || real time viewing of data || web server || alarm notification by e-mail”,”value”:”diagnostic via predefined web pages || real time viewing of data || web server || alarm notification by e-mail”},{“name”:”Power Quality Analysis”,”normalizedValue”:”up to the 63rd harmonic”,”value”:”up to the 63rd harmonic”},{“name”:”Weee”,”normalizedValue”:”The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.”,”value”:”The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.”},{“name”:”Pollution Degree”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Connections – Terminals”,”normalizedValue”:”voltage circuit screw terminal block4 || control circuit screw terminal block2 || current transformer screw terminal block6 || RS485 link screw terminal block4 || digital input screw terminal block8 || digital output screw terminal block4 || Ethernet network RJ45 connector2″,”value”:”voltage circuit screw terminal block4 || control circuit screw terminal block2 || current transformer screw terminal block6 || RS485 link screw terminal block4 || digital input screw terminal block8 || digital output screw terminal block4 || Ethernet network RJ45 connector2″},{“name”:”Type Of Measurement”,”normalizedValue”:”current || voltage || frequency || power factor || energy || active and reactive power”,”value”:”current || voltage || frequency || power factor || energy || active and reactive power”},{“name”:”Analogue Input Type”,”normalizedValue”:”voltage 5 MOhm) || current \u003c= 0.3 mOhm)”,”value”:”voltage 5 MOhm) || current \u003c= 0.3 mOhm)”},{“name”:”Ethernet Service”,”normalizedValue”:”SNTP client || SNMP-Traps”,”value”:”SNTP client || SNMP-Traps”},{“name”:”Communication Port Protocol”,”normalizedValue”:”Modbus RTU and ASCII 9.6, 19.2 and 38.4 kbauds even/odd or none – 2 wires 2500 V || JBUS || Modbus TCP/IP 10/100 Mbit/s 2500 V || Ethernet Modbus TCP/IP daisy chain || BACnet IP || DNP3 over ethernet”,”value”:”Modbus RTU and ASCII 9.6, 19.2 and 38.4 kbauds even/odd or none – 2 wires 2500 V || JBUS || Modbus TCP/IP 10/100 Mbit/s 2500 V || Ethernet Modbus TCP/IP daisy chain || BACnet IP || DNP3 over ethernet”},{“name”:”Ride-Through Time”,”normalizedValue”:”35 ms 120 V AC typical || 129 ms 230 V AC typical || 50 ms 125 V DC typical”,”value”:”35 ms 120 V AC typical || 129 ms 230 V AC typical || 50 ms 125 V DC typical”},{“name”:”Frequency Measurement Range”,”normalizedValue”:”45-65 Hz”,”value”:”45-65 Hz”},{“name”:”Communication Port Support”,”normalizedValue”:”RS485 || ETHERNET”,”value”:”RS485 || ETHERNET”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”display IP54 IEC 60529 || rear IP30 IEC 60529″,”value”:”display IP54 IEC 60529 || rear IP30 IEC 60529″},{“name”:”Circularity Profile”,”normalizedValue”:”ENVEOLI1412028EN”,”value”:”ENVEOLI1412028EN”},{“name”:”Measurement Current”,”normalizedValue”:”50-10000 mA”,”value”:”50-10000 mA”},{“name”:”Measurement Accuracy”,”normalizedValue”:”apparent power +/- 0.5 % || frequency +/- 0.05 % || active energy +/- 0.2 % || reactive energy +/- 1 % || active power +/- 0.2 % || voltage +/- 0.1 % || power factor +/- 0.005 || current +/- 0.15 % || reactive power +/- 1 %”,”value”:”apparent power +/- 0.5 % || frequency +/- 0.05 % || active energy +/- 0.2 % || reactive energy +/- 1 % || active power +/- 0.2 % || voltage +/- 0.1 % || power factor +/- 0.005 || current +/- 0.15 % || reactive power +/- 1 %”},{“name”:”Device Short Name”,”normalizedValue”:”PM5563″,”value”:”PM5563″},{“name”:”Number Of Inputs”,”normalizedValue”:”4 digital”,”value”:”4 digital”},{“name”:”Device Application”,”normalizedValue”:”gateway || power monitoring || WAGES metering || multi-tariff”,”value”:”gateway || power monitoring || WAGES metering || multi-tariff”},{“name”:”Primary/Ambient Air Temp.”,”normalizedValue”:”-25-70 C, -40-85°C”,”value”:”-25-70°C; -40-85°C”},{“name”:”Range”,”normalizedValue”:”PowerLogic”,”value”:”PowerLogic”},{“name”:”Memory Capacity”,”normalizedValue”:”1.1 MB”,”value”:”1.1 MB”},{“name”:”Network Frequency”,”normalizedValue”:”50 Hz || 60 Hz”,”value”:”50 Hz || 60 Hz”},{“name”:”Maximum Power Consumption In Va”,”normalizedValue”:”16 VA 480 V”,”value”:”16 VA 480 V”},{“name”:”Sampling Rate”,”normalizedValue”:”128 samples/cycle”,”value”:”128 samples/cycle”},{“name”:”Metering Type”,”normalizedValue”:”measured neutral current || calculated ground current”,”value”:”measured neutral current || calculated ground current”},{“name”:”Information Displayed”,”normalizedValue”:”tariff 8)”,”value”:”tariff 8)”},{“name”:”Measurement Voltage”,”normalizedValue”:”20-400 V AC 45…65 Hz between phase and neutral || 20-828 V AC 45…65 Hz between phases”,”value”:”20-400 V AC 45…65 Hz between phase and neutral || 20-828 V AC 45…65 Hz between phases”},{“name”:”Communication Gateway”,”normalizedValue”:”Ethernet/serial”,”value”:”Ethernet/serial”},{“name”:”Number Of Outputs”,”normalizedValue”:”2 digital”,”value”:”2 digital”},{“name”:”Display Resolution”,”normalizedValue”:”128 x 128 pixels”,”value”:”128 x 128 pixels”},{“name”:”Electromagnetic Compatibility”,”normalizedValue”:”limits for harmonic current emissionsclass A IEC 61000-3-2 || conducted RF disturbanceslevel 3 IEC 61000-4-6 || magnetic field at power frequencylevel 4 IEC 61000-4-8 || conducted and radiated emissionsclass B EN 55022 || limitation of voltage changes, voltage fluctuations and flicker in low-voltage IEC 61000-3-3 || electrostatic discharge 8 kVlevel 4 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test IEC 61000-4-3 || electrical fast transient/burst immunity testlevel 4 IEC 61000-4-4 || surge immunity testlevel 4 IEC 61000-4-5 || voltage dips and interruptions immunity test IEC 61000-4-11″,”value”:”limits for harmonic current emissionsclass A IEC 61000-3-2 || conducted RF disturbanceslevel 3 IEC 61000-4-6 || magnetic field at power frequencylevel 4 IEC 61000-4-8 || conducted and radiated emissionsclass B EN 55022 || limitation of voltage changes, voltage fluctuations and flicker in low-voltage IEC 61000-3-3 || electrostatic discharge 8 kVlevel 4 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test IEC 61000-4-3 || electrical fast transient/burst immunity testlevel 4 IEC 61000-4-4 || surge immunity testlevel 4 IEC 61000-4-5 || voltage dips and interruptions immunity test IEC 61000-4-11″},{“name”:”Data Recording”,”normalizedValue”:”time stamping || data logs || maintenance logs || event logs || alarm logs || min/max of instantaneous values”,”value”:”time stamping || data logs || maintenance logs || event logs || alarm logs || min/max of instantaneous values”},{“name”:”[Us] Rated Supply Voltage”,”normalizedValue”:”100…300 V DC || 90…528 V AC 45…65 Hz”,”value”:”100…300 V DC || 90…528 V AC 45…65 Hz”},{“name”:”Relative Humidity”,”normalizedValue”:”5-95 % 50-50°C non-condensing”,”value”:”5-95 % 50-50°C non-condensing”},{“name”:”Operating Altitude”,”normalizedValue”:”\u003c= 9842.52 ft (3000 m)”,”value”:”\u003c= 9842.52 ft (3000 m)”},{“name”:”Display Type”,”normalizedValue”:”remote LCD display”,”value”:”remote LCD display”},{“name”:”Mounting Support”,”normalizedValue”:”DIN rail”,”value”:”DIN rail”},{“name”:”Number Of Poles”,”normalizedValue”:”1P + N || 3P || 3P + N”,”value”:”1P + N || 3P || 3P + N”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”India”,”value”:”India”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.