Metal Clad Building Cable, MC; FPLP, 14 AWG, 2C with Ground C, Red, Aluminum, Solid, 600V AC

$377,99

Metal Clad Armored Cable, Trade Designation MC-FPLP, Wire Size 14 AWG, Number of Conductors 2, Wire Color Black/Green/White, Jacket Color Red, Length 250 ft, Conductor Design Solid, Jacket Material Aluminum, Insulation Material PVC, Nominal Outside Dia. 0.44 in, Packaging Coil, Voltage 600 V, Temp. Rating -6.8 Degrees to 194 Degrees F Dry

9999 in stock

SKU: GRG8166776 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Metal Clad Building Cable”,”rank”:1,”value”:”Metal Clad Building Cable”},{“name”:”Trade Designation”,”normalizedValue”:”MC; FPLP”,”rank”:2,”value”:”MC; FPLP”},{“name”:”Wire Size”,”normalizedValue”:”14 AWG”,”rank”:3,”value”:”14 AWG”},{“name”:”Conductor Material”,”normalizedValue”:”Copper”,”rank”:4,”value”:”Copper”},{“name”:”Number of Conductors”,”normalizedValue”:”2C with Ground”,”rank”:5,”value”:”2C with Ground”},{“name”:”Wire Color”,”normalizedValue”:”Black/Green/White”,”rank”:6,”value”:”Black/Green/White”},{“name”:”Jacket Color”,”normalizedValue”:”Red”,”rank”:7,”value”:”Red”},{“name”:”Jacket Material”,”normalizedValue”:”Aluminum”,”rank”:8,”value”:”Aluminum”},{“name”:”Conductor Design”,”normalizedValue”:”Solid”,”rank”:10,”value”:”Solid”},{“name”:”Insulation Material”,”normalizedValue”:”PVC”,”rank”:11,”value”:”PVC”},{“name”:”Voltage”,”normalizedValue”:”600V AC”,”rank”:12,”value”:”600V AC”},{“name”:”Length”,”normalizedValue”:”250 ft”,”rank”:13,”value”:”250 ft”},{“name”:”Temp. Rating”,”normalizedValue”:”90 deg C”,”rank”:14,”value”:”90°C”},{“name”:”Standards”,”normalizedValue”:”UL 83, 1063, 1424, 1569, NFPA 262-2002 Standard Method of Test for Flame and Smoke of Wire and Cables for Use In Air Handling Spaces, Federal Specification A-A59544 (Formerly J-C-30B), IEEE 1202, Vertical Cable Tray Flame Test, 2011 National Electrical Code, Approved for The State of Rhode Island Fire Systems, Listed for Use In UL 1, 2, and 3 Hour Through Penetration Firestop Systems, NFPA 70 (NEC)”,”rank”:15,”value”:”UL 83, 1063, 1424, 1569, NFPA 262-2002 Standard Method of Test for Flame and Smoke of Wire and Cables for Use In Air Handling Spaces, Federal Specification A-A59544 (Formerly J-C-30B), IEEE 1202, Vertical Cable Tray Flame Test, 2011 National Electrical Code, Approved for The State of Rhode Island Fire Systems, Listed for Use In UL 1, 2, and 3 Hour Through Penetration Firestop Systems, NFPA 70 (NEC)”},{“name”:”Application”,”normalizedValue”:”Indoor”,”value”:”Indoor”},{“name”:”Max. Amps”,”normalizedValue”:”15″,”value”:”15″},{“name”:”Nominal Outside Dia.”,”normalizedValue”:”0.439 in”,”value”:”0.439 in”},{“name”:”Stranding”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Conductor Size”,”normalizedValue”:”14 AWG”,”value”:”14 AWG”},{“name”:”Packaging”,”normalizedValue”:”Coil”,”value”:”Coil”},{“name”:”Shielding”,”normalizedValue”:”Shielded”,”value”:”Shielded”},{“name”:”Shielding Material”,”normalizedValue”:”Aluminum”,”value”:”Aluminum”},{“name”:”Overall Length”,”normalizedValue”:”250 ft”,”value”:”250 ft”},{“name”:”Insulation Thickness (Mils)”,”normalizedValue”:”15 mil”,”value”:”15mils”},{“name”:”Applications”,”normalizedValue”:”ApplicationRed Alert® Type MC-FPLP Cable is suitable for use as follows:Wiring in Plenums, Ducts or Other Spaces Used for Environmental Air-Handling Purposes per NEC 300.22(C) \u0026 760.135(C).Power-Limited and Non-Power Limited fire alarm circuits, including smoke detectors, bells, horns, fire alarm control panel equipment, and initiation and signaling devicesClass 1, Class 2, and Class 3 remote control, signaling, and power-limited circuits.Power, lighting, control, and signal circuits.Fished or embedded in plasterConcealed or exposed installations.Places of Assembly per NEC 518.4 and Theaters per NEC 520.5.Installation in cable tray and approved raceways.Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) \u0026 645.5(D)(2).”,”value”:”ApplicationRed Alert® Type MC-FPLP Cable is suitable for use as follows:Wiring in Plenums, Ducts or Other Spaces Used for Environmental Air-Handling Purposes per NEC 300.22(C) \u0026 760.135(C).Power-Limited and Non-Power Limited fire alarm circuits, including smoke detectors, bells, horns, fire alarm control panel equipment, and initiation and signaling devicesClass 1, Class 2, and Class 3 remote control, signaling, and power-limited circuits.Power, lighting, control, and signal circuits.Fished or embedded in plasterConcealed or exposed installations.Places of Assembly per NEC 518.4 and Theaters per NEC 520.5.Installation in cable tray and approved raceways.Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) \u0026 645.5(D)(2).”},{“name”:”Construction”,”normalizedValue”:”ConstructionType TFN conductors are provided for sizes 18 AWG and 16 AWG cables. The cable is dual rated as 90°C dry, 600 Volt Type MC and 105°C dry, 300 Volt Type FPLP cable.”,”value”:”ConstructionType TFN conductors are provided for sizes 18 AWG and 16 AWG cables. The cable is dual rated as 90°C dry, 600 Volt Type MC and 105°C dry, 300 Volt Type FPLP cable.”},{“name”:”Number of Ground Conductors”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”-6.8 Degrees F”,”value”:”-6.8 Degrees F”},{“name”:”Nominal Outside Diameter”,”normalizedValue”:”0.44 in”,”value”:”0.44 in”},{“name”:”Trade Designation – Conductors”,”normalizedValue”:”THHN”,”value”:”THHN”},{“name”:”Series”,”normalizedValue”:”Red Alert(R) Type MC-FPLP”,”value”:”Red Alert(R) Type MC-FPLP”},{“name”:”Number of Strands”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Includes Bonding Wire”,”normalizedValue”:”No Bonding Wire”,”value”:”No Bonding Wire”},{“name”:”Grounding Conductor Insulation Color”,”normalizedValue”:”Green”,”value”:”Green”},{“name”:”Number of Neutrals”,”normalizedValue”:”0″,”value”:”0″},{“name”:”Grounding Conductor Material”,”normalizedValue”:”Copper”,”value”:”Copper”},{“name”:”Grounding Conductor Size”,”normalizedValue”:”14 AWG”,”value”:”14 AWG”},{“name”:”Grounding Conductor Insulation Material”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Conductor Insulation Material”,”normalizedValue”:”PVC”,”value”:”PVC”},{“name”:”Number of Shielded Pairs”,”normalizedValue”:”0″,”value”:”0″},{“name”:”Conductor Insulation Color”,”normalizedValue”:”White, Black”,”value”:”Black, White”},{“name”:”Temperature Rating – Maximum Wet”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Hazardous Location Specification”,”normalizedValue”:”Class I, Div 2, Group A, B, C, D, Class II, Div 2, Group E, F, G, Class III, Div 1″,”value”:”Class I, Div 2, Group A, B, C, D, Class II, Div 2, Group E, F, G, Class III, Div 1″},{“name”:”Temperature Rating – Maximum Dry”,”normalizedValue”:”194 deg F”,”value”:”194 Degrees F”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Metal Clad Building Cable, MC; FPLP, 14 AWG, 2C with Ground C, Red, Aluminum, Solid, 600V AC”