Metal Clad Building Cable, MC, 14 AWG, 3C with Ground C, Silver, Aluminum, Solid, 600V AC, 50 ft

$64,99

Metal Clad Armored Cable, Trade Designation MC, Wire Size 14 AWG, Number of Conductors 3, Wire Color Black/Green/Red/White, Jacket Color Silver, Length 50 ft, Conductor Design Solid, Jacket Material Aluminum, Insulation Material PVC, Nominal Outside Dia. 0.46 in, Packaging Coil, Voltage 600 V, Temp. Rating -6.8 Degrees to 194 Degrees F Dry

9999 in stock

SKU: GRG7803302 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Metal Clad Building Cable”,”rank”:1,”value”:”Metal Clad Building Cable”},{“name”:”Trade Designation”,”normalizedValue”:”MC”,”rank”:2,”value”:”MC”},{“name”:”Wire Size”,”normalizedValue”:”14 AWG”,”rank”:3,”value”:”14 AWG”},{“name”:”Conductor Material”,”normalizedValue”:”Copper”,”rank”:4,”value”:”Copper”},{“name”:”Number of Conductors”,”normalizedValue”:”3C with Ground”,”rank”:5,”value”:”3C with Ground”},{“name”:”Wire Color”,”normalizedValue”:”Black/Green/Red/White”,”rank”:6,”value”:”Black/Green/Red/White”},{“name”:”Jacket Color”,”normalizedValue”:”Silver”,”rank”:7,”value”:”Silver”},{“name”:”Jacket Material”,”normalizedValue”:”Aluminum”,”rank”:8,”value”:”Aluminum”},{“name”:”Conductor Design”,”normalizedValue”:”Solid”,”rank”:10,”value”:”Solid”},{“name”:”Insulation Material”,”normalizedValue”:”PVC”,”rank”:11,”value”:”PVC”},{“name”:”Voltage”,”normalizedValue”:”600V AC”,”rank”:12,”value”:”600V AC”},{“name”:”Length”,”normalizedValue”:”50 ft”,”rank”:13,”value”:”50 ft”},{“name”:”Temp. Rating”,”normalizedValue”:”90 deg C”,”rank”:14,”value”:”90°C”},{“name”:”Standards”,”normalizedValue”:”UL 83, 1569, 1685, NEC Article 330, Federal Specification A-A59544 (Formerly J-C-30B), FT4/IEEE 1202, Vertical Cable Tray Flame Test, Listed for Use In UL 1, 2 and 3 Hour Through Penetration Firestop Systems”,”rank”:15,”value”:”UL 83, 1569, 1685, NEC Article 330, Federal Specification A-A59544 (Formerly J-C-30B), FT4/IEEE 1202, Vertical Cable Tray Flame Test, Listed for Use In UL 1, 2 and 3 Hour Through Penetration Firestop Systems”},{“name”:”Max. Amps”,”normalizedValue”:”15″,”value”:”15″},{“name”:”Application”,”normalizedValue”:”Indoor”,”value”:”Indoor”},{“name”:”Nominal Outside Dia.”,”normalizedValue”:”0.464 in”,”value”:”0.464 in”},{“name”:”Conductor Size”,”normalizedValue”:”14 AWG”,”value”:”14 AWG”},{“name”:”Stranding”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Packaging”,”normalizedValue”:”Coil”,”value”:”Coil”},{“name”:”Shielding”,”normalizedValue”:”Shielded”,”value”:”Shielded”},{“name”:”Overall Length”,”normalizedValue”:”50 ft”,”value”:”50 ft”},{“name”:”Shielding Material”,”normalizedValue”:”Aluminum”,”value”:”Aluminum”},{“name”:”Construction”,”normalizedValue”:”ConstructionSouthwire Armorlite® Type MC Cable is constructed with soft-drawn copper, Type THHN/THWN conductors rated 90°C dry available in sizes 14 AWG through 2 AWG, and a green insulated grounding conductor. The conductors are cabled together and a binder tape bearing the print legend is wrapped around the assembly. Aluminum interlocking armor is applied over the assembly.”,”value”:”ConstructionSouthwire Armorlite® Type MC Cable is constructed with soft-drawn copper, Type THHN/THWN conductors rated 90°C dry available in sizes 14 AWG through 2 AWG, and a green insulated grounding conductor. The conductors are cabled together and a binder tape bearing the print legend is wrapped around the assembly. Aluminum interlocking armor is applied over the assembly.”},{“name”:”Insulation Thickness (Mils)”,”normalizedValue”:”15 mil”,”value”:”15mils”},{“name”:”Applications”,”normalizedValue”:”ApplicationSouthwire Armorlite® Type MC Cable is suitable for use as follows:Branch, feeder and service power distribution in commercial, industrial, institutional, and multiresidential buildings.Fished or embedded in plaster.Concealed or exposed installationsEnvironmental air-handling spaces per NEC 300.22 (C).Places of Assembly per NEC 518.4 and theaters per NEC 520.5.Installation in cable tray and approved raceways.Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.”,”value”:”ApplicationSouthwire Armorlite® Type MC Cable is suitable for use as follows:Branch, feeder and service power distribution in commercial, industrial, institutional, and multiresidential buildings.Fished or embedded in plaster.Concealed or exposed installationsEnvironmental air-handling spaces per NEC 300.22 (C).Places of Assembly per NEC 518.4 and theaters per NEC 520.5.Installation in cable tray and approved raceways.Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.”},{“name”:”Series”,”normalizedValue”:”Armorlite(R)”,”value”:”Armorlite(R)”},{“name”:”Grounding Conductor Material”,”normalizedValue”:”Copper”,”value”:”Copper”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”-6.8 deg F”,”value”:”-6.8 Degrees F”},{“name”:”Conductor Insulation Color”,”normalizedValue”:”White, Black, Red”,”value”:”Black, Red, White”},{“name”:”Temperature Rating – Maximum Wet”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Grounding Conductor Insulation Material”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Number of Neutrals”,”normalizedValue”:”0″,”value”:”0″},{“name”:”Hazardous Location Specification”,”normalizedValue”:”Class I, Div 2, Group A, B, C, D, Class II, Div 2, Group E, F, G, Class III, Div 1″,”value”:”Class I, Div 2, Group A, B, C, D, Class II, Div 2, Group E, F, G, Class III, Div 1″},{“name”:”Conductor Insulation Material”,”normalizedValue”:”PVC”,”value”:”PVC”},{“name”:”Grounding Conductor Size”,”normalizedValue”:”14 AWG”,”value”:”14 AWG”},{“name”:”Number of Ground Conductors”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Grounding Conductor Insulation Color”,”normalizedValue”:”Green”,”value”:”Green”},{“name”:”Trade Designation – Conductors”,”normalizedValue”:”THHN”,”value”:”THHN”},{“name”:”Number of Strands”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Number of Shielded Pairs”,”normalizedValue”:”0″,”value”:”0″},{“name”:”Temperature Rating – Maximum Dry”,”normalizedValue”:”194 deg F”,”value”:”194 Degrees F”},{“name”:”Includes Bonding Wire”,”normalizedValue”:”No Bonding Wire”,”value”:”No Bonding Wire”},{“name”:”Nominal Outside Diameter”,”normalizedValue”:”0.46 in”,”value”:”0.46 in”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Metal Clad Building Cable, MC, 14 AWG, 3C with Ground C, Silver, Aluminum, Solid, 600V AC, 50 ft”